Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Mengting Qiu on 2025/06/10 18:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -474,25 +474,51 @@ 474 474 475 475 == 3.3 Add or Delete RS485 Sensor == 476 476 477 +((( 477 477 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. 479 +))) 478 478 481 +((( 479 479 (% style="color:#037691" %)**AT Command: ** 483 +))) 480 480 485 +((( 481 481 (% style="color:blue" %)**AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout** 487 +))) 482 482 483 -* Type_Code range: A1 ~~ A4 484 -* Query_Length: RS485 Query frame length, Value cannot be greater than 10 485 -* Query_Command: RS485 Query frame data to be sent to sensor, cannot be larger than 10 bytes 486 -* Read_Length: RS485 response frame length supposed to receive. Max can receive 487 -* Valid_Data: valid data from RS485 Response, Valid Data will be added to Payload and upload via LoRaWAN. 488 -* has_CRC: RS485 Response crc check (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0. 489 -* timeout: RS485 receive timeout (uint:ms). Device will close receive window after timeout 489 +* ((( 490 +Type_Code range: A1 ~~ A4 491 +))) 492 +* ((( 493 +Query_Length: RS485 Query frame length, Value cannot be greater than 10 494 +))) 495 +* ((( 496 +Query_Command: RS485 Query frame data to be sent to sensor, cannot be larger than 10 bytes 497 +))) 498 +* ((( 499 +Read_Length: RS485 response frame length supposed to receive. Max can receive 500 +))) 501 +* ((( 502 +Valid_Data: valid data from RS485 Response, Valid Data will be added to Payload and upload via LoRaWAN. 503 +))) 504 +* ((( 505 +has_CRC: RS485 Response crc check (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0. 506 +))) 507 +* ((( 508 +timeout: RS485 receive timeout (uint:ms). Device will close receive window after timeout 509 +))) 490 490 511 +((( 491 491 **Example:** 513 +))) 492 492 515 +((( 493 493 User need to change external sensor use the type code as address code. 517 +))) 494 494 519 +((( 495 495 With a 485 sensor, after correctly changing the address code to A1, the RS485 query frame is shown in the following table: 521 +))) 496 496 497 497 [[image:image-20220624143553-10.png]] 498 498