<
From version < 79.16 >
edited by Xiaoling
on 2022/06/24 17:20
To version < 78.2 >
edited by Xiaoling
on 2022/06/24 16:16
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -61,16 +61,14 @@
61 61  [[image:1656042136605-251.png]]
62 62  
63 63  
64 -(% style="color:red" %)**Notice 1:**
64 +(% style="color:red" %) ** Notice 1:**
65 65  
66 66  * All weather sensors and WSC1-L are powered by MPPT solar recharge controller. MPPT is connected to solar panel and storage battery.
67 67  * WSC1-L has an extra 1000mAh back up battery. So it can work even solar panel and storage battery Fails.
68 68  * Weather sensors won’t work if solar panel and storage battery fails.
69 69  
70 +(% style="color:red" %)** Notice 2:**
70 70  
71 -
72 -(% style="color:red" %)**Notice 2:**
73 -
74 74  Due to shipment and importation limitation, user is better to purchase below parts locally:
75 75  
76 76  * Solar Panel
... ... @@ -79,10 +79,6 @@
79 79  * Mounting Kit includes pole and mast assembly. Each weather sensor has it’s own mounting assembly, user can check the sensor section in this manual.
80 80  * Cabinet.
81 81  
82 -
83 -
84 -
85 -
86 86  == 2.2 How it works? ==
87 87  
88 88  (((
... ... @@ -90,9 +90,7 @@
90 90  )))
91 91  
92 92  
93 -(((
94 94  Open WSC1-L and put the yellow jumper as below position to power on WSC1-L.
95 -)))
96 96  
97 97  [[image:1656042192857-709.png]]
98 98  
... ... @@ -102,9 +102,6 @@
102 102  1. WSC1-L will auto scan available weather sensors when power on or reboot.
103 103  1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors.
104 104  
105 -
106 -
107 -
108 108  == 2.3 Example to use for LoRaWAN network ==
109 109  
110 110  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -147,9 +147,7 @@
147 147  
148 148  
149 149  
150 -(((
151 151  (% style="color:blue" %)**Step 2**(%%): Power on WSC1-L, it will start to join TTN server. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel.
152 -)))
153 153  
154 154  
155 155  [[image:1656042745346-283.png]]
... ... @@ -163,9 +163,6 @@
163 163  * Valid Sensor Value: Use FPORT=2
164 164  * Other control command: Use FPORT other than 2.
165 165  
166 -
167 -
168 -
169 169  === 2.4.1 Uplink FPORT~=5, Device Status ===
170 170  
171 171  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -230,13 +230,9 @@
230 230  
231 231  ==== (% style="color:#037691" %)**BAT:**(%%) ====
232 232  
233 -(((
234 234  shows the battery voltage for WSC1-L MCU.
235 -)))
236 236  
237 -(((
238 238  Ex1: 0x0BD6/1000 = 3.03 V
239 -)))
240 240  
241 241  
242 242  
... ... @@ -304,50 +304,22 @@
304 304  [[image:image-20220624140352-2.png]]
305 305  
306 306  
307 -(((
308 308  Below is an example payload:  [[image:image-20220624140615-3.png]]
309 -)))
310 310  
311 -(((
312 -
313 -)))
314 314  
315 -(((
316 316  When sending this payload to LoRaWAN server. WSC1-L will send this in one uplink or several uplinks according to LoRaWAN spec requirement. For example, total length of Payload is 54 bytes.
317 -)))
318 318  
319 -* (((
320 -When WSC1-L sending in US915 frequency DR0 data rate. Because this data rate has limitation of 11 bytes payload for each uplink. The payload will be split into below packets and uplink.
321 -)))
292 +* When WSC1-L sending in US915 frequency DR0 data rate. Because this data rate has limitation of 11 bytes payload for each uplink. The payload will be split into below packets and uplink.
322 322  
323 -(((
324 324   Uplink 1:  [[image:image-20220624140735-4.png]]
325 -)))
326 326  
327 -(((
328 -
329 -)))
330 -
331 -(((
332 332   Uplink 2:  [[image:image-20220624140842-5.png]]
333 -)))
334 334  
335 -(((
336 -
337 -)))
338 338  
339 -* (((
340 -When WSC1-L sending in EU868 frequency DR0 data rate. The payload will be split into below packets and uplink:
341 -)))
299 +* When WSC1-L sending in EU868 frequency DR0 data rate. The payload will be split into below packets and uplink:
342 342  
343 -(((
344 344   Uplink 1:  [[image:image-20220624141025-6.png]]
345 -)))
346 346  
347 -(((
348 -
349 -)))
350 -
351 351   Uplink 2:  [[image:image-20220624141100-7.png]]
352 352  
353 353  
... ... @@ -444,9 +444,6 @@
444 444  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
445 445  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
446 446  
447 -
448 -
449 -
450 450  == 3.2 Set Emergency Mode ==
451 451  
452 452  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
... ... @@ -461,9 +461,6 @@
461 461  * 0xE101     Same as: AT+ALARMMOD=1
462 462  * 0xE100     Same as: AT+ALARMMOD=0
463 463  
464 -
465 -
466 -
467 467  == 3.3 Add or Delete RS485 Sensor ==
468 468  
469 469  Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors.
... ... @@ -533,9 +533,6 @@
533 533  
534 534  * 0xE5FF  
535 535  
536 -
537 -
538 -
539 539  == 3.4 RS485 Test Command ==
540 540  
541 541  (% style="color:#037691" %)**AT Command:**
... ... @@ -557,9 +557,6 @@
557 557  
558 558  * 0xE20103000001840A     Same as: AT+RSWRITE=0103000001840A
559 559  
560 -
561 -
562 -
563 563  == 3.5 RS485 response timeout ==
564 564  
565 565  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -583,18 +583,11 @@
583 583  * Example 1: Downlink Payload: E0000005 ~/~/ Set Transmit Interval (DTR) = 5 seconds
584 584  * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds
585 585  
586 -
587 -
588 -
589 589  == 3.6 Set Sensor Type ==
590 590  
591 -(((
592 592  Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.
593 -)))
594 594  
595 -(((
596 596  See [[definition>>||anchor="HWeatherSensorTypes:"]] for the sensor type.
597 -)))
598 598  
599 599  [[image:image-20220624144904-12.png]]
600 600  
... ... @@ -668,9 +668,6 @@
668 668  * IP Rating: IP65
669 669  * Support default sensors or 3rd party RS485 sensors
670 670  
671 -
672 -
673 -
674 674  == 5.2 Power Consumption ==
675 675  
676 676  WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA
... ... @@ -738,9 +738,6 @@
738 738  * ABS enclosure.
739 739  * Horizontal adjustable.
740 740  
741 -
742 -
743 -
744 744  === 6.1.2 Specification ===
745 745  
746 746  * Resolution: 0.2mm
... ... @@ -752,9 +752,6 @@
752 752  * Working Humidity: <100% (no dewing)
753 753  * Power Consumption: 4mA @ 12v.
754 754  
755 -
756 -
757 -
758 758  === 6.1.3 Dimension ===
759 759  
760 760   [[image:1656054957406-980.png]]
... ... @@ -767,31 +767,19 @@
767 767  
768 768  === 6.1.5 Installation Notice ===
769 769  
770 -(((
771 771  Do not power on while connect the cables. Double check the wiring before power on.
772 -)))
773 773  
774 -(((
775 775  Installation Photo as reference:
776 -)))
777 777  
778 778  
779 -(((
780 780  (% style="color:#4472c4" %)** Install on Ground:**
781 -)))
782 782  
783 -(((
784 784  WSS-01 Rain Gauge include screws so can install in ground directly .
785 -)))
786 786  
787 787  
788 -(((
789 789  (% style="color:#4472c4" %)** Install on pole:**
790 -)))
791 791  
792 -(((
793 793  If user want to install on pole, they can purchase the (% style="color:#4472c4" %)** WS-K2 :  Bracket Kit for Pole installation**(%%), and install as below:
794 -)))
795 795  
796 796  [[image:image-20220624152218-1.png||height="526" width="276"]]
797 797  
... ... @@ -825,9 +825,6 @@
825 825  * RS485 wind speed / direction sensor
826 826  * PC enclosure, resist corrosion
827 827  
828 -
829 -
830 -
831 831  === 6.2.2 Specification ===
832 832  
833 833  * Wind speed range: 0 ~~ 30m/s, (always show 30m/s for higher speed)
... ... @@ -841,9 +841,6 @@
841 841  * Power Consumption: 13mA ~~ 12v.
842 842  * Cable Length: 2 meters
843 843  
844 -
845 -
846 -
847 847  === 6.2.3 Dimension ===
848 848  
849 849  [[image:image-20220624152813-2.png]]
... ... @@ -861,13 +861,9 @@
861 861  
862 862  === 6.2.6  Installation Notice ===
863 863  
864 -(((
865 865  Do not power on while connect the cables. Double check the wiring before power on.
866 -)))
867 867  
868 -(((
869 869  The sensor must be installed with below direction, towards North.
870 -)))
871 871  
872 872  [[image:image-20220624153901-3.png]]
873 873  
... ... @@ -894,9 +894,6 @@
894 894  * NDIR to measure CO2 with Internal Temperature Compensation
895 895  * Laser Beam Scattering to PM2.5 and PM10
896 896  
897 -
898 -
899 -
900 900  === 6.3.2 Specification ===
901 901  
902 902  * CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃)
... ... @@ -914,9 +914,6 @@
914 914  ** CO2: 0~95%RH
915 915  * Power Consumption: 50mA@ 12v.
916 916  
917 -
918 -
919 -
920 920  === 6.3.3 Dimension ===
921 921  
922 922  [[image:1656056708366-230.png]]
... ... @@ -931,6 +931,8 @@
931 931  
932 932  Do not power on while connect the cables. Double check the wiring before power on.
933 933  
830 +[[image:1656057016033-551.png]]
831 +
934 934  [[image:1656056751153-304.png]]
935 935  
936 936  [[image:1656056766224-773.png]]
... ... @@ -959,9 +959,6 @@
959 959  * Surface heating to dry
960 960  * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion
961 961  
962 -
963 -
964 -
965 965  === 6.4.2 Specification ===
966 966  
967 967  * Detect if there is rain or snow
... ... @@ -973,9 +973,6 @@
973 973  ** No heating: 12mA @ 12v,
974 974  ** heating: 94ma @ 12v.
975 975  
976 -
977 -
978 -
979 979  === 6.4.3 Dimension ===
980 980  
981 981  [[image:1656056844782-155.png]]
... ... @@ -991,9 +991,7 @@
991 991  Do not power on while connect the cables. Double check the wiring before power on.
992 992  
993 993  
994 -(((
995 995  Install with 15°degree.
996 -)))
997 997  
998 998   [[image:1656056873783-780.png]]
999 999  
... ... @@ -1024,9 +1024,6 @@
1024 1024  
1025 1025  * RS485 Temperature, Humidity, Illuminance, Pressure sensor
1026 1026  
1027 -
1028 -
1029 -
1030 1030  === 6.5.2 Specification ===
1031 1031  
1032 1032  * Input Power: DC 12 ~~ 24v
... ... @@ -1051,9 +1051,6 @@
1051 1051  * Working Humidity: 10~90%RH
1052 1052  * Power Consumption: 4mA @ 12v
1053 1053  
1054 -
1055 -
1056 -
1057 1057  === 6.5.3 Dimension ===
1058 1058  
1059 1059  [[image:1656057170639-522.png]]
... ... @@ -1097,9 +1097,6 @@
1097 1097  * Measure Total Radiation between 0.3~3μm(300~3000nm)
1098 1098  * Measure Reflected Radiation if sense area towards ground.
1099 1099  
1100 -
1101 -
1102 -
1103 1103  === 6.6.2 Specification ===
1104 1104  
1105 1105  * Input Power: DC 5 ~~ 24v
... ... @@ -1115,9 +1115,6 @@
1115 1115  * Working Humidity: 10~90%RH
1116 1116  * Power Consumption: 4mA @ 12v
1117 1117  
1118 -
1119 -
1120 -
1121 1121  === 6.6.3 Dimension ===
1122 1122  
1123 1123  [[image:1656057348695-898.png]]
... ... @@ -1156,13 +1156,9 @@
1156 1156  
1157 1157  === 6.7.1 Feature ===
1158 1158  
1159 -(((
1160 1160  PAR (Photosynthetically Available Radiation) sensor measure 400 ~~ 700nm wavelength nature light's Photosynthetically Available Radiation.
1161 -)))
1162 1162  
1163 -(((
1164 1164  When nature light shine on the sense area, it will generate a signal base on the incidence radiation strength.
1165 -)))
1166 1166  
1167 1167  
1168 1168  === 6.7.2 Specification ===
... ... @@ -1178,9 +1178,6 @@
1178 1178  * Working Humidity: 10~90%RH
1179 1179  * Power Consumption: 3mA @ 12v
1180 1180  
1181 -
1182 -
1183 -
1184 1184  === 6.7.3 Dimension ===
1185 1185  
1186 1186  [[image:1656057538793-888.png]]
... ... @@ -1267,10 +1267,12 @@
1267 1267  * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
1268 1268  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1269 1269  
1141 +
1142 +
1270 1270  == 9.2 Sensors ==
1271 1271  
1272 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:350px" %)
1273 -|=(% style="width: 300px;" %)**Sensor Model**|=(% style="width: 50px;" %)**Part Number**
1145 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
1146 +|=(% style="width: 462px;" %)**Sensor Model**|=(% style="width: 110px;" %)**Part Number**
1274 1274  |(% style="width:462px" %)**Rain Gauge**|(% style="width:110px" %)WSS-01
1275 1275  |(% style="width:462px" %)**Rain Gauge installation Bracket for Pole**|(% style="width:110px" %)WS-K2
1276 1276  |(% style="width:462px" %)**Wind Speed Direction 2 in 1 Sensor**|(% style="width:110px" %)WSS-02
... ... @@ -1281,6 +1281,8 @@
1281 1281  |(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:110px" %)WSS-07
1282 1282  
1283 1283  
1157 +
1158 +
1284 1284  = 10. Support =
1285 1285  
1286 1286  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
... ... @@ -1287,6 +1287,8 @@
1287 1287  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
1288 1288  
1289 1289  
1165 +
1166 +
1290 1290  = 11. Appendix I: Field Installation Photo =
1291 1291  
1292 1292  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0