Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/05/07 14:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -67,8 +67,6 @@ 67 67 * WSC1-L has an extra 1000mAh back up battery. So it can work even solar panel and storage battery Fails. 68 68 * Weather sensors won’t work if solar panel and storage battery fails. 69 69 70 - 71 - 72 72 (% style="color:red" %)**Notice 2:** 73 73 74 74 Due to shipment and importation limitation, user is better to purchase below parts locally: ... ... @@ -82,7 +82,6 @@ 82 82 83 83 84 84 85 - 86 86 == 2.2 How it works? == 87 87 88 88 ((( ... ... @@ -355,14 +355,25 @@ 355 355 356 356 === 2.4.3 Decoder in TTN V3 === 357 357 355 +((( 358 358 In LoRaWAN platform, user only see HEX payload by default, user needs to use payload formatters to decode the payload to see human-readable value. 357 +))) 359 359 359 +((( 360 + 361 +))) 360 360 363 +((( 361 361 Download decoder for suitable platform from: 365 +))) 362 362 367 +((( 363 363 [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Weather_Station/WSC1-L/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Weather_Station/WSC1-L/]] 369 +))) 364 364 371 +((( 365 365 and put as below: 373 +))) 366 366 367 367 [[image:1656051152438-578.png]] 368 368 ... ... @@ -370,12 +370,21 @@ 370 370 371 371 == 2.5 Show data on Application Server == 372 372 381 +((( 373 373 Application platform provides a human friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps: 383 +))) 374 374 385 +((( 386 + 387 +))) 375 375 389 +((( 376 376 (% style="color:blue" %)**Step 1**(%%): Be sure that your device is programmed and properly connected to the LoRaWAN network. 391 +))) 377 377 393 +((( 378 378 (% style="color:blue" %)**Step 2**(%%): Configure your Application to forward data to Datacake you will need to add integration. Go to TTN V3 Console ~-~-> Applications ~-~-> Integrations ~-~-> Add Integrations. 395 +))) 379 379 380 380 [[image:1656051197172-131.png]] 381 381 ... ... @@ -423,9 +423,6 @@ 423 423 424 424 425 425 426 - 427 - 428 - 429 429 == 3.1 Set Transmit Interval Time == 430 430 431 431 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -466,25 +466,51 @@ 466 466 467 467 == 3.3 Add or Delete RS485 Sensor == 468 468 483 +((( 469 469 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. 485 +))) 470 470 487 +((( 471 471 (% style="color:#037691" %)**AT Command: ** 489 +))) 472 472 491 +((( 473 473 (% style="color:blue" %)**AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout** 493 +))) 474 474 475 -* Type_Code range: A1 ~~ A4 476 -* Query_Length: RS485 Query frame length, Value cannot be greater than 10 477 -* Query_Command: RS485 Query frame data to be sent to sensor, cannot be larger than 10 bytes 478 -* Read_Length: RS485 response frame length supposed to receive. Max can receive 479 -* Valid_Data: valid data from RS485 Response, Valid Data will be added to Payload and upload via LoRaWAN. 480 -* has_CRC: RS485 Response crc check (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0. 481 -* timeout: RS485 receive timeout (uint:ms). Device will close receive window after timeout 495 +* ((( 496 +Type_Code range: A1 ~~ A4 497 +))) 498 +* ((( 499 +Query_Length: RS485 Query frame length, Value cannot be greater than 10 500 +))) 501 +* ((( 502 +Query_Command: RS485 Query frame data to be sent to sensor, cannot be larger than 10 bytes 503 +))) 504 +* ((( 505 +Read_Length: RS485 response frame length supposed to receive. Max can receive 506 +))) 507 +* ((( 508 +Valid_Data: valid data from RS485 Response, Valid Data will be added to Payload and upload via LoRaWAN. 509 +))) 510 +* ((( 511 +has_CRC: RS485 Response crc check (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0. 512 +))) 513 +* ((( 514 +timeout: RS485 receive timeout (uint:ms). Device will close receive window after timeout 515 +))) 482 482 517 +((( 483 483 **Example:** 519 +))) 484 484 521 +((( 485 485 User need to change external sensor use the type code as address code. 523 +))) 486 486 525 +((( 487 487 With a 485 sensor, after correctly changing the address code to A1, the RS485 query frame is shown in the following table: 527 +))) 488 488 489 489 [[image:image-20220624143553-10.png]] 490 490 ... ... @@ -767,19 +767,31 @@ 767 767 768 768 === 6.1.5 Installation Notice === 769 769 810 +((( 770 770 Do not power on while connect the cables. Double check the wiring before power on. 812 +))) 771 771 814 +((( 772 772 Installation Photo as reference: 816 +))) 773 773 774 774 819 +((( 775 775 (% style="color:#4472c4" %)** Install on Ground:** 821 +))) 776 776 823 +((( 777 777 WSS-01 Rain Gauge include screws so can install in ground directly . 825 +))) 778 778 779 779 828 +((( 780 780 (% style="color:#4472c4" %)** Install on pole:** 830 +))) 781 781 832 +((( 782 782 If user want to install on pole, they can purchase the (% style="color:#4472c4" %)** WS-K2 : Bracket Kit for Pole installation**(%%), and install as below: 834 +))) 783 783 784 784 [[image:image-20220624152218-1.png||height="526" width="276"]] 785 785 ... ... @@ -849,9 +849,13 @@ 849 849 850 850 === 6.2.6 Installation Notice === 851 851 904 +((( 852 852 Do not power on while connect the cables. Double check the wiring before power on. 906 +))) 853 853 908 +((( 854 854 The sensor must be installed with below direction, towards North. 910 +))) 855 855 856 856 [[image:image-20220624153901-3.png]] 857 857 ... ... @@ -915,8 +915,6 @@ 915 915 916 916 Do not power on while connect the cables. Double check the wiring before power on. 917 917 918 -[[image:1656057016033-551.png]] 919 - 920 920 [[image:1656056751153-304.png]] 921 921 922 922 [[image:1656056766224-773.png]] ... ... @@ -977,7 +977,9 @@ 977 977 Do not power on while connect the cables. Double check the wiring before power on. 978 978 979 979 1034 +((( 980 980 Install with 15°degree. 1036 +))) 981 981 982 982 [[image:1656056873783-780.png]] 983 983 ... ... @@ -1083,7 +1083,6 @@ 1083 1083 1084 1084 1085 1085 1086 - 1087 1087 === 6.6.2 Specification === 1088 1088 1089 1089 * Input Power: DC 5 ~~ 24v ... ... @@ -1140,9 +1140,13 @@ 1140 1140 1141 1141 === 6.7.1 Feature === 1142 1142 1198 +((( 1143 1143 PAR (Photosynthetically Available Radiation) sensor measure 400 ~~ 700nm wavelength nature light's Photosynthetically Available Radiation. 1200 +))) 1144 1144 1202 +((( 1145 1145 When nature light shine on the sense area, it will generate a signal base on the incidence radiation strength. 1204 +))) 1146 1146 1147 1147 1148 1148 === 6.7.2 Specification === ... ... @@ -1247,10 +1247,11 @@ 1247 1247 * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1248 1248 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1249 1249 1309 + 1250 1250 == 9.2 Sensors == 1251 1251 1252 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width: 510px" %)1253 -|=(% style="width: 462px;" %)**Sensor Model**|=(% style="width: 110px;" %)**Part Number**1312 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:400px" %) 1313 +|=(% style="width: 300px;" %)**Sensor Model**|=(% style="width: 100px;" %)**Part Number** 1254 1254 |(% style="width:462px" %)**Rain Gauge**|(% style="width:110px" %)WSS-01 1255 1255 |(% style="width:462px" %)**Rain Gauge installation Bracket for Pole**|(% style="width:110px" %)WS-K2 1256 1256 |(% style="width:462px" %)**Wind Speed Direction 2 in 1 Sensor**|(% style="width:110px" %)WSS-02 ... ... @@ -1267,10 +1267,13 @@ 1267 1267 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1268 1268 1269 1269 1330 + 1331 + 1332 + 1270 1270 = 11. Appendix I: Field Installation Photo = 1271 1271 1272 1272 1273 -[[image:1656058346362-132.png]] 1336 +[[image:1656058346362-132.png||height="685" width="732"]] 1274 1274 1275 1275 **Storage Battery**: 12v,12AH li battery 1276 1276 ... ... @@ -1278,13 +1278,13 @@ 1278 1278 1279 1279 **Wind Speed/Direction** 1280 1280 1281 -[[image:1656058373174-421.png]] 1344 +[[image:1656058373174-421.png||height="356" width="731"]] 1282 1282 1283 1283 1284 1284 1285 1285 **Total Solar Radiation sensor** 1286 1286 1287 -[[image:1656058397364-282.png]] 1350 +[[image:1656058397364-282.png||height="453" width="732"]] 1288 1288 1289 1289 1290 1290 ... ... @@ -1296,7 +1296,7 @@ 1296 1296 1297 1297 **CO2/PM2.5/PM10 3 in 1 sensor** 1298 1298 1299 -[[image:1656058441194-827.png]] 1362 +[[image:1656058441194-827.png||height="672" width="523"]] 1300 1300 1301 1301 1302 1302 ... ... @@ -1308,4 +1308,4 @@ 1308 1308 1309 1309 **Rain Gauge** 1310 1310 1311 -[[image:1656058463455-569.png]] 1374 +[[image:1656058463455-569.png||height="499" width="550"]]