Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/04/25 09:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -67,7 +67,6 @@ 67 67 * WSC1-L has an extra 1000mAh back up battery. So it can work even solar panel and storage battery Fails. 68 68 * Weather sensors won’t work if solar panel and storage battery fails. 69 69 70 - 71 71 (% style="color:red" %)** Notice 2:** 72 72 73 73 Due to shipment and importation limitation, user is better to purchase below parts locally: ... ... @@ -79,9 +79,6 @@ 79 79 * Cabinet. 80 80 81 81 82 - 83 - 84 - 85 85 == 2.2 How it works? == 86 86 87 87 ((( ... ... @@ -100,9 +100,6 @@ 100 100 1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors. 101 101 102 102 103 - 104 - 105 - 106 106 == 2.3 Example to use for LoRaWAN network == 107 107 108 108 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. ... ... @@ -406,9 +406,6 @@ 406 406 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 407 407 408 408 409 - 410 - 411 - 412 412 == 3.2 Set Emergency Mode == 413 413 414 414 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. ... ... @@ -424,9 +424,6 @@ 424 424 * 0xE100 Same as: AT+ALARMMOD=0 425 425 426 426 427 - 428 - 429 - 430 430 == 3.3 Add or Delete RS485 Sensor == 431 431 432 432 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. ... ... @@ -468,7 +468,6 @@ 468 468 * has_CRC: 1 469 469 * timeout: 1500 (Fill in the test according to the actual situation) 470 470 471 - 472 472 **So the input command is:** 473 473 474 474 AT+DYSENSOR=A1,8,A103000000019CAA,8,24,1,1500 ... ... @@ -498,9 +498,6 @@ 498 498 * 0xE5FF 499 499 500 500 501 - 502 - 503 - 504 504 == 3.4 RS485 Test Command == 505 505 506 506 (% style="color:#037691" %)**AT Command:** ... ... @@ -523,9 +523,6 @@ 523 523 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 524 524 525 525 526 - 527 - 528 - 529 529 == 3.5 RS485 response timeout == 530 530 531 531 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -550,9 +550,6 @@ 550 550 * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds 551 551 552 552 553 - 554 - 555 - 556 556 == 3.6 Set Sensor Type == 557 557 558 558 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values. ... ... @@ -698,8 +698,6 @@ 698 698 * ABS enclosure. 699 699 * Horizontal adjustable. 700 700 701 - 702 - 703 703 === 6.1.2 Specification === 704 704 705 705 * Resolution: 0.2mm ... ... @@ -711,8 +711,6 @@ 711 711 * Working Humidity: <100% (no dewing) 712 712 * Power Consumption: 4mA @ 12v. 713 713 714 - 715 - 716 716 === 6.1.3 Dimension === 717 717 718 718 [[image:1656054957406-980.png]] ... ... @@ -771,8 +771,6 @@ 771 771 * RS485 wind speed / direction sensor 772 772 * PC enclosure, resist corrosion 773 773 774 - 775 - 776 776 === 6.2.2 Specification === 777 777 778 778 * Wind speed range: 0 ~~ 30m/s, (always show 30m/s for higher speed) ... ... @@ -786,8 +786,6 @@ 786 786 * Power Consumption: 13mA ~~ 12v. 787 787 * Cable Length: 2 meters 788 788 789 - 790 - 791 791 === 6.2.3 Dimension === 792 792 793 793 [[image:image-20220624152813-2.png]] ... ... @@ -834,8 +834,6 @@ 834 834 * NDIR to measure CO2 with Internal Temperature Compensation 835 835 * Laser Beam Scattering to PM2.5 and PM10 836 836 837 - 838 - 839 839 === 6.3.2 Specification === 840 840 841 841 * CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃) ... ... @@ -853,8 +853,6 @@ 853 853 ** CO2: 0~95%RH 854 854 * Power Consumption: 50mA@ 12v. 855 855 856 - 857 - 858 858 === 6.3.3 Dimension === 859 859 860 860 [[image:1656056708366-230.png]] ... ... @@ -899,8 +899,6 @@ 899 899 * Surface heating to dry 900 900 * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion 901 901 902 - 903 - 904 904 === 6.4.2 Specification === 905 905 906 906 * Detect if there is rain or snow ... ... @@ -912,8 +912,6 @@ 912 912 ** No heating: 12mA @ 12v, 913 913 ** heating: 94ma @ 12v. 914 914 915 - 916 - 917 917 === 6.4.3 Dimension === 918 918 919 919 [[image:1656056844782-155.png]] ... ... @@ -960,8 +960,6 @@ 960 960 961 961 * RS485 Temperature, Humidity, Illuminance, Pressure sensor 962 962 963 - 964 - 965 965 === 6.5.2 Specification === 966 966 967 967 * Input Power: DC 12 ~~ 24v ... ... @@ -986,8 +986,6 @@ 986 986 * Working Humidity: 10~90%RH 987 987 * Power Consumption: 4mA @ 12v 988 988 989 - 990 - 991 991 === 6.5.3 Dimension === 992 992 993 993 [[image:1656057170639-522.png]] ... ... @@ -1031,8 +1031,6 @@ 1031 1031 * Measure Total Radiation between 0.3~3μm(300~3000nm) 1032 1032 * Measure Reflected Radiation if sense area towards ground. 1033 1033 1034 - 1035 - 1036 1036 === 6.6.2 Specification === 1037 1037 1038 1038 * Input Power: DC 5 ~~ 24v ... ... @@ -1048,8 +1048,6 @@ 1048 1048 * Working Humidity: 10~90%RH 1049 1049 * Power Consumption: 4mA @ 12v 1050 1050 1051 - 1052 - 1053 1053 === 6.6.3 Dimension === 1054 1054 1055 1055 [[image:1656057348695-898.png]] ... ... @@ -1106,8 +1106,6 @@ 1106 1106 * Working Humidity: 10~90%RH 1107 1107 * Power Consumption: 3mA @ 12v 1108 1108 1109 - 1110 - 1111 1111 === 6.7.3 Dimension === 1112 1112 1113 1113 [[image:1656057538793-888.png]] ... ... @@ -1135,47 +1135,50 @@ 1135 1135 1136 1136 Below is the installation photo and structure: 1137 1137 1138 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image002.png]]1089 +[[image:1656057598349-319.png]] 1139 1139 1140 1140 1141 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image039.png]]1092 +[[image:1656057608049-693.png]] 1142 1142 1143 1143 1144 1144 1145 - 1146 1146 == 7.2 How to upgrade firmware for WSC1-L? == 1147 1147 1098 +((( 1148 1148 Firmware Location & Change log: 1100 +))) 1149 1149 1102 +((( 1150 1150 [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/WSC1-L/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/WSC1-L/]] 1104 +))) 1151 1151 1152 1152 1153 -Firmware Upgrade instruction: 1107 +((( 1108 +Firmware Upgrade instruction: [[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome||anchor="H2.HardwareUpgradeMethodSupportList"]] 1109 +))) 1154 1154 1155 -[[https:~~/~~/wiki.dragino.com/index.php?title=Firmware_Upgrade_Instruction_for_STM32_base_products#Hardware_Upgrade_Method_Support_List>>url:https://wiki.dragino.com/index.php?title=Firmware_Upgrade_Instruction_for_STM32_base_products#Hardware_Upgrade_Method_Support_List]] 1156 1156 1157 - 1158 1158 == 7.3 How to change the LoRa Frequency Bands/Region? == 1159 1159 1160 -User can follow the introduction for how to upgrade image. When download the images, choose the required image file for download. 1114 +User can follow the introduction for how to [[upgrade image>>||anchor="H7.2HowtoupgradefirmwareforWSC1-L3F"]]. When download the images, choose the required image file for download. 1161 1161 1162 1162 1163 - 1164 1164 == 7.4 Can I add my weather sensors? == 1165 1165 1166 -Yes, connect the sensor to RS485 bus and see instruction: path:#Add_sensor]]1119 +Yes, connect the sensor to RS485 bus and see instruction: [[add sensors.>>||anchor="H3.3AddorDeleteRS485Sensor"]] 1167 1167 1168 1168 1169 1169 = 8. Trouble Shooting = 1170 1170 1124 +== 8.1 AT Command input doesn't work == 1171 1171 1126 +((( 1127 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1128 +))) 1172 1172 1173 1173 1174 - 1175 - 1176 1176 = 9. Order Info = 1177 1177 1178 - 1179 1179 == 9.1 Main Process Unit == 1180 1180 1181 1181 Part Number: (% style="color:blue" %)**WSC1-L-XX** ... ... @@ -1192,29 +1192,31 @@ 1192 1192 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1193 1193 1194 1194 1149 + 1150 + 1195 1195 == 9.2 Sensors == 1196 1196 1197 -|**Sensor Model**|**Part Number** 1198 -|**Rain Gauge**|WSS-01 1199 -|**Rain Gauge installation Bracket for Pole**|WS-K2 1200 -|**Wind Speed Direction 2 in 1 Sensor**|WSS-02 1201 -|**CO2/PM2.5/PM10 3 in 1 Sensor**|WSS-03 1202 -|**Rain/Snow Detect Sensor**|WSS-04 1203 -|**Temperature, Humidity, illuminance and Pressure 4 in 1 sensor**|WSS-05 1204 -|**Total Solar Radiation Sensor**|WSS-06 1205 -|**PAR (Photosynthetically Available Radiation)**|WSS-07 1153 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 1154 +|=(% style="width: 462px;" %)**Sensor Model**|=(% style="width: 110px;" %)**Part Number** 1155 +|(% style="width:462px" %)**Rain Gauge**|(% style="width:110px" %)WSS-01 1156 +|(% style="width:462px" %)**Rain Gauge installation Bracket for Pole**|(% style="width:110px" %)WS-K2 1157 +|(% style="width:462px" %)**Wind Speed Direction 2 in 1 Sensor**|(% style="width:110px" %)WSS-02 1158 +|(% style="width:462px" %)**CO2/PM2.5/PM10 3 in 1 Sensor**|(% style="width:110px" %)WSS-03 1159 +|(% style="width:462px" %)**Rain/Snow Detect Sensor**|(% style="width:110px" %)WSS-04 1160 +|(% style="width:462px" %)**Temperature, Humidity, illuminance and Pressure 4 in 1 sensor**|(% style="width:110px" %)WSS-05 1161 +|(% style="width:462px" %)**Total Solar Radiation Sensor**|(% style="width:110px" %)WSS-06 1162 +|(% style="width:462px" %)**PAR (Photosynthetically Available Radiation)**|(% style="width:110px" %)WSS-07 1206 1206 1164 + 1207 1207 = 10. Support = 1208 1208 1209 1209 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1210 -* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to 1168 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1211 1211 1212 -[[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1213 1213 1214 1214 1215 1215 1216 1216 1217 - 1218 1218 = 11. Appendix I: Field Installation Photo = 1219 1219 1220 1220