... ... @@ -50,15 +50,15 @@
50 50  
51 51  
52 52  
53 -
54 54  = 2. How to use =
55 55  
56 56  == 2.1 Installation ==
57 57  
58 -Below is an installation example for the weather station. Field installation example can be found at [[Appendix I: Field Installation Photo.>>||anchor="H"]] 
57 +Below is an installation example for the weather station. Field installation example can be found at [[Appendix I: Field Installation Photo.>>||anchor="H11.AppendixI:FieldInstallationPhoto"]] 
59 59  
60 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image002.png]]
59 +[[image:1656041948552-849.png]]
61 61  
61 +
62 62  (% style="color:blue" %)** Wiring:**
63 63  
64 64  ~1. WSC1-L and sensors all powered by solar power via MPPT
... ... @@ -501,7 +501,6 @@
501 501  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
502 502  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
503 503  
504 -
505 505  == 3.2 Set Emergency Mode ==
506 506  
507 507  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
... ... @@ -518,7 +518,6 @@
518 518  * 0xE101     Same as: AT+ALARMMOD=1
519 519  * 0xE100     Same as: AT+ALARMMOD=0
520 520  
521 -
522 522  == 3.3 Add or Delete RS485 Sensor ==
523 523  
524 524  Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors.
... ... @@ -588,7 +588,6 @@
588 588  
589 589  * 0xE5FF  
590 590  
591 -
592 592  == 3.4 RS485 Test Command ==
593 593  
594 594  (% style="color:#037691" %)**AT Command:**
... ... @@ -609,7 +609,6 @@
609 609  
610 610  * 0xE20103000001840A     Same as: AT+RSWRITE=0103000001840A
611 611  
612 -
613 613  == 3.5 RS485 response timeout ==
614 614  
615 615  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -632,7 +632,6 @@
632 632  * Example 1: Downlink Payload: E0000005 ~/~/ Set Transmit Interval (DTR) = 5 seconds
633 633  * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds
634 634  
635 -
636 636  == 3.6 Set Sensor Type ==
637 637  
638 638  Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.
... ... @@ -730,7 +730,6 @@
730 730  * IP Rating: IP65
731 731  * Support default sensors or 3rd party RS485 sensors
732 732  
733 -
734 734  == 5.2 Power Consumption ==
735 735  
736 736  WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA