Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/04/25 09:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -77,6 +77,7 @@ 77 77 * Mounting Kit includes pole and mast assembly. Each weather sensor has it’s own mounting assembly, user can check the sensor section in this manual. 78 78 * Cabinet. 79 79 80 + 80 80 == 2.2 How it works? == 81 81 82 82 ((( ... ... @@ -94,6 +94,7 @@ 94 94 1. WSC1-L will auto scan available weather sensors when power on or reboot. 95 95 1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors. 96 96 98 + 97 97 == 2.3 Example to use for LoRaWAN network == 98 98 99 99 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. ... ... @@ -153,6 +153,7 @@ 153 153 154 154 155 155 158 + 156 156 === 2.4.1 Uplink FPORT~=5, Device Status === 157 157 158 158 Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours ... ... @@ -377,6 +377,7 @@ 377 377 These commands only valid for WSC1-L, as below: 378 378 379 379 383 + 380 380 == 3.1 Set Transmit Interval Time == 381 381 382 382 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -396,6 +396,7 @@ 396 396 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 397 397 398 398 403 + 399 399 == 3.2 Set Emergency Mode == 400 400 401 401 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. ... ... @@ -411,6 +411,7 @@ 411 411 * 0xE100 Same as: AT+ALARMMOD=0 412 412 413 413 419 + 414 414 == 3.3 Add or Delete RS485 Sensor == 415 415 416 416 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. ... ... @@ -427,6 +427,7 @@ 427 427 * has_CRC: RS485 Response crc check (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0. 428 428 * timeout: RS485 receive timeout (uint:ms). Device will close receive window after timeout 429 429 436 + 430 430 **Example:** 431 431 432 432 User need to change external sensor use the type code as address code. ... ... @@ -480,6 +480,7 @@ 480 480 * 0xE5FF 481 481 482 482 490 + 483 483 == 3.4 RS485 Test Command == 484 484 485 485 (% style="color:#037691" %)**AT Command:** ... ... @@ -502,6 +502,7 @@ 502 502 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 503 503 504 504 513 + 505 505 == 3.5 RS485 response timeout == 506 506 507 507 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -526,6 +526,7 @@ 526 526 * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds 527 527 528 528 538 + 529 529 == 3.6 Set Sensor Type == 530 530 531 531 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values. ... ... @@ -588,6 +588,7 @@ 588 588 ))) 589 589 590 590 601 + 591 591 = 5. Main Process Unit WSC1-L = 592 592 593 593 == 5.1 Features == ... ... @@ -605,11 +605,13 @@ 605 605 * Support default sensors or 3rd party RS485 sensors 606 606 607 607 619 + 608 608 == 5.2 Power Consumption == 609 609 610 610 WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA 611 611 612 612 625 + 613 613 == 5.3 Storage & Operation Temperature == 614 614 615 615 -20°C to +60°C ... ... @@ -617,7 +617,7 @@ 617 617 618 618 == 5.4 Pin Mapping == 619 619 620 -[[image: 1656054149793-239.png]]633 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image004.png]] 621 621 622 622 623 623 == 5.5 Mechanical == ... ... @@ -625,12 +625,14 @@ 625 625 Refer LSn50v2 enclosure drawing in: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/>>url:https://www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/]] 626 626 627 627 641 + 642 + 628 628 == 5.6 Connect to RS485 Sensors == 629 629 630 630 WSC1-L includes a RS485 converter PCB. Which help it easy to connect multiply RS485 sensors. Below is the photo for reference. 631 631 632 632 633 -[[image: 1656054389031-379.png]]648 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image018.png]] 634 634 635 635 636 636 Hardware Design for the Converter Board please see: ... ... @@ -638,22 +638,37 @@ 638 638 [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Weather_Station/RS485_Converter_Board/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Weather_Station/RS485_Converter_Board/]] 639 639 640 640 656 + 657 + 658 + 641 641 = 6. Weather Sensors = 642 642 643 643 == 6.1 Rain Gauge ~-~- WSS-01 == 644 644 645 - 646 646 WSS-01 RS485 Rain Gauge is used in meteorology and hydrology to gather and measure the amount of liquid precipitation (mainly rainfall) over an area. 647 647 648 -WSS-01 uses a tipping bucket to detect rainfall. The tipping bucket use 3D streamline shape to make sure it works smoothly and is easy to clean. 649 649 650 -WSS-01 isdesignedtosupport the DraginoWeatherstationsolution. Users only needo connectWSS-01 RS485interface to WSC1-L. Theweather station mainprocessor WSC1-L can detectandupload therainfallto the IoT Server viawireless LoRaWAN protocol666 +WSS-01 uses a tipping bucket to detect rainfall. The tipping bucket use 3D streamline 651 651 652 - The tippingbucketof WSS-01 isadjustedtothe bestangle. When installation, useronly needstoscrewupand adjustthe bottomhorizontally.668 +shape to make sure it works smoothly and is easy to clean. 653 653 670 + 671 +WSS-01 is designed to support the Dragino Weather station solution. 672 + 673 +Users only need to connect WSS-01 RS485 interface to WSC1-L. The weather station main 674 + 675 +processor WSC1-L can detect and upload the rainfall to the IoT Server via wireless LoRaWAN protocol 676 + 677 + 678 +The tipping bucket of WSS-01 is adjusted to the best angle. When installation, user only needs 679 + 680 +to screw up and adjust the bottom horizontally. 681 + 682 + 654 654 WSS-01 package includes screw which can be installed to ground. If user want to install WSS-01 on pole, they can purchase WS-K2 bracket kit. 655 655 656 656 686 + 657 657 === 6.1.1 Feature === 658 658 659 659 * RS485 Rain Gauge ... ... @@ -662,10 +662,6 @@ 662 662 * ABS enclosure. 663 663 * Horizontal adjustable. 664 664 665 - 666 - 667 - 668 - 669 669 === 6.1.2 Specification === 670 670 671 671 * Resolution: 0.2mm ... ... @@ -677,10 +677,6 @@ 677 677 * Working Humidity: <100% (no dewing) 678 678 * Power Consumption: 4mA @ 12v. 679 679 680 - 681 - 682 - 683 - 684 684 === 6.1.3 Dimension === 685 685 686 686 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image019.jpg||alt="c2d3aee592ccc873bea6dd891451df2"]] ... ... @@ -742,10 +742,6 @@ 742 742 * RS485 wind speed / direction sensor 743 743 * PC enclosure, resist corrosion 744 744 745 - 746 - 747 - 748 - 749 749 === 6.2.2 Specification === 750 750 751 751 * Wind speed range: 0 ~~ 30m/s, (always show 30m/s for higher speed) ... ... @@ -759,10 +759,6 @@ 759 759 * Power Consumption: 13mA ~~ 12v. 760 760 * Cable Length: 2 meters 761 761 762 - 763 - 764 - 765 - 766 766 === 6.2.3 Dimension === 767 767 768 768 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.jpg]][[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.jpg]] ... ... @@ -820,10 +820,6 @@ 820 820 * NDIR to measure CO2 with Internal Temperature Compensation 821 821 * Laser Beam Scattering to PM2.5 and PM10 822 822 823 - 824 - 825 - 826 - 827 827 === 6.3.2 Specification === 828 828 829 829 * CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃) ... ... @@ -841,10 +841,6 @@ 841 841 ** CO2: 0~95%RH 842 842 * Power Consumption: 50mA@ 12v. 843 843 844 - 845 - 846 - 847 - 848 848 === 6.3.3 Dimension === 849 849 850 850 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]] ... ... @@ -890,10 +890,6 @@ 890 890 * Surface heating to dry 891 891 * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion 892 892 893 - 894 - 895 - 896 - 897 897 === 6.4.2 Specification === 898 898 899 899 * Detect if there is rain or snow ... ... @@ -905,10 +905,6 @@ 905 905 ** No heating: 12mA @ 12v, 906 906 ** heating: 94ma @ 12v. 907 907 908 - 909 - 910 - 911 - 912 912 === 6.4.3 Dimension === 913 913 914 914 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image031.png]] ... ... @@ -958,10 +958,6 @@ 958 958 959 959 * RS485 Temperature, Humidity, Illuminance, Pressure sensor 960 960 961 - 962 - 963 - 964 - 965 965 === 6.5.2 Specification === 966 966 967 967 * Input Power: DC 12 ~~ 24v ... ... @@ -986,10 +986,6 @@ 986 986 * Working Humidity: 10~90%RH 987 987 * Power Consumption: 4mA @ 12v 988 988 989 - 990 - 991 - 992 - 993 993 === 6.5.3 Dimension === 994 994 995 995 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image034.jpg]] ... ... @@ -1035,10 +1035,6 @@ 1035 1035 * Measure Total Radiation between 0.3~3μm(300~3000nm) 1036 1036 * Measure Reflected Radiation if sense area towards ground. 1037 1037 1038 - 1039 - 1040 - 1041 - 1042 1042 === 6.6.2 Specification === 1043 1043 1044 1044 * Input Power: DC 5 ~~ 24v ... ... @@ -1054,10 +1054,6 @@ 1054 1054 * Working Humidity: 10~90%RH 1055 1055 * Power Consumption: 4mA @ 12v 1056 1056 1057 - 1058 - 1059 - 1060 - 1061 1061 === 6.6.3 Dimension === 1062 1062 1063 1063 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] ... ... @@ -1115,10 +1115,6 @@ 1115 1115 * Working Humidity: 10~90%RH 1116 1116 * Power Consumption: 3mA @ 12v 1117 1117 1118 - 1119 - 1120 - 1121 - 1122 1122 === 6.7.3 Dimension === 1123 1123 1124 1124 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] ... ... @@ -1188,23 +1188,19 @@ 1188 1188 1189 1189 == 9.1 Main Process Unit == 1190 1190 1191 -Part Number: ** (% style="color:blue" %)WSC1-L-XX**1169 +Part Number: **WSC1-L-XX** 1192 1192 1193 -** (% style="color:blue" %)XX**(%%): The default frequency band1171 +**XX**: The default frequency band 1194 1194 1195 -* ** (% style="color:red" %)AS923**(%%): LoRaWAN AS923 band1196 -* ** (% style="color:red" %)AU915**(%%): LoRaWAN AU915 band1197 -* ** (% style="color:red" %)EU433**(%%): LoRaWAN EU433 band1198 -* ** (% style="color:red" %)EU868**(%%): LoRaWAN EU868 band1199 -* ** (% style="color:red" %)KR920**(%%): LoRaWAN KR920 band1200 -* ** (% style="color:red" %)US915**(%%): LoRaWAN US915 band1201 -* ** (% style="color:red" %)IN865**(%%): LoRaWAN IN865 band1202 -* ** (% style="color:red" %)CN470**(%%): LoRaWAN CN470 band1173 +* **AS923**: LoRaWAN AS923 band 1174 +* **AU915**: LoRaWAN AU915 band 1175 +* **EU433**: LoRaWAN EU433 band 1176 +* **EU868**: LoRaWAN EU868 band 1177 +* **KR920**: LoRaWAN KR920 band 1178 +* **US915**: LoRaWAN US915 band 1179 +* **IN865**: LoRaWAN IN865 band 1180 +* **CN470**: LoRaWAN CN470 band 1203 1203 1204 - 1205 - 1206 - 1207 - 1208 1208 == 9.2 Sensors == 1209 1209 1210 1210 |**Sensor Model**|**Part Number** ... ... @@ -1217,8 +1217,6 @@ 1217 1217 |**Total Solar Radiation Sensor**|WSS-06 1218 1218 |**PAR (Photosynthetically Available Radiation)**|WSS-07 1219 1219 1220 - 1221 - 1222 1222 = 10. Support = 1223 1223 1224 1224 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
- 1656054149793-239.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -492.6 KB - Content
- 1656054389031-379.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.3 MB - Content