<
From version < 32.9 >
edited by Xiaoling
on 2022/06/24 14:57
To version < 31.3 >
edited by Xiaoling
on 2022/06/24 14:36
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -78,8 +78,6 @@
78 78  * Cabinet.
79 79  
80 80  
81 -
82 -
83 83  == 2.2 How it works? ==
84 84  
85 85  (((
... ... @@ -98,8 +98,6 @@
98 98  1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors.
99 99  
100 100  
101 -
102 -
103 103  == 2.3 Example to use for LoRaWAN network ==
104 104  
105 105  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -156,8 +156,6 @@
156 156  * Valid Sensor Value: Use FPORT=2
157 157  * Other control command: Use FPORT other than 2.
158 158  
159 -
160 -
161 161  === 2.4.1 Uplink FPORT~=5, Device Status ===
162 162  
163 163  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -401,6 +401,8 @@
401 401  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
402 402  
403 403  
398 +
399 +
404 404  == 3.2 Set Emergency Mode ==
405 405  
406 406  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
... ... @@ -416,6 +416,8 @@
416 416  * 0xE100     Same as: AT+ALARMMOD=0
417 417  
418 418  
415 +
416 +
419 419  == 3.3 Add or Delete RS485 Sensor ==
420 420  
421 421  Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors.
... ... @@ -422,7 +422,7 @@
422 422  
423 423  (% style="color:#037691" %)**AT Command: **
424 424  
425 -(% style="color:blue" %)**AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout**
423 +**AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout**
426 426  
427 427  * Type_Code range:  A1 ~~ A4
428 428  * Query_Length:  RS485 Query frame length, Value cannot be greater than 10
... ... @@ -432,6 +432,7 @@
432 432  * has_CRC:  RS485 Response crc check  (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0.
433 433  * timeout:  RS485 receive timeout (uint:ms). Device will close receive window after timeout
434 434  
433 +
435 435  **Example:**
436 436  
437 437  User need to change external sensor use the type code as address code.
... ... @@ -446,7 +446,7 @@
446 446  [[image:image-20220624143618-11.png]]
447 447  
448 448  
449 -**Then the following parameters should be:**
448 +Then the following parameters should be:
450 450  
451 451  * Address_Code range: A1
452 452  * Query_Length: 8
... ... @@ -456,22 +456,22 @@
456 456  * has_CRC: 1
457 457  * timeout: 1500 (Fill in the test according to the actual situation)
458 458  
459 -**So the input command is:**
460 460  
459 +So the input command is:
460 +
461 461  AT+DYSENSOR=A1,8,A103000000019CAA,8,24,1,1500
462 462  
463 463  
464 464  In every sampling. WSC1-L will auto append the sensor segment as per this structure and uplink.
465 465  
466 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:351px" %)
467 -|=(% style="width: 94px;" %)Type Code|=(% style="width: 121px;" %)Length (Bytes)|=(% style="width: 132px;" %)Measured Value
468 -|(% style="width:94px" %)A1|(% style="width:121px" %)2|(% style="width:132px" %)0x000A
466 +|Type Code|Length (Bytes)|Measured Value
467 +|A1|2|0x000A
469 469  
470 -**Related commands:**
469 +Related commands:
471 471  
472 -AT+DYSENSOR=A1,0  ~-~->  Delete 3^^rd^^ party sensor A1.
471 +AT+DYSENSOR=A1,0 > Delete 3^^rd^^ party sensor A1.
473 473  
474 -AT+DYSENSOR  ~-~->  List All 3^^rd^^ Party Sensor. Like below:
473 +AT+DYSENSOR ~-~-> List All 3^^rd^^ Party Sensor. Like below:
475 475  
476 476  
477 477  (% style="color:#037691" %)**Downlink Command:  **
... ... @@ -485,17 +485,18 @@
485 485  * 0xE5FF  
486 486  
487 487  
487 +
488 +
488 488  == 3.4 RS485 Test Command ==
489 489  
490 490  (% style="color:#037691" %)**AT Command:**
491 491  
492 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:474px" %)
493 -|=(% style="width: 159px;" %)**Command Example**|=(% style="width: 227px;" %)**Function**|=(% style="width: 85px;" %)**Response**
494 -|(% style="width:159px" %)AT+RSWRITE=xxxxxx|(% style="width:227px" %)(((
493 +|**Command Example**|**Function**|**Response**
494 +|AT+RSWRITE=xxxxxx|(((
495 495  Send command to 485 sensor
496 496  
497 497  Range : no more than 10 bytes
498 -)))|(% style="width:85px" %)OK
498 +)))|OK
499 499  
500 500  Eg: Send command **01 03 00 00 00 01 84 0A** to 485 sensor
501 501  
... ... @@ -507,6 +507,8 @@
507 507  * 0xE20103000001840A     Same as: AT+RSWRITE=0103000001840A
508 508  
509 509  
510 +
511 +
510 510  == 3.5 RS485 response timeout ==
511 511  
512 512  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -513,13 +513,12 @@
513 513  
514 514  (% style="color:#037691" %)**AT Command:**
515 515  
516 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:433px" %)
517 -|=(% style="width: 157px;" %)**Command Example**|=(% style="width: 188px;" %)**Function**|=(% style="width: 85px;" %)**Response**
518 -|(% style="width:157px" %)AT+DTR=1000|(% style="width:188px" %)(((
518 +|**Command Example**|**Function**|**Response**
519 +|AT+DTR=1000|(((
519 519  Set response timeout to:
520 520  
521 521  Range : 0~~10000
522 -)))|(% style="width:85px" %)OK
523 +)))|OK
523 523  
524 524  (% style="color:#037691" %)**Downlink Command:**
525 525  
... ... @@ -531,31 +531,51 @@
531 531  * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds
532 532  
533 533  
535 +
536 +
534 534  == 3.6 Set Sensor Type ==
535 535  
536 536  Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.
537 537  
538 -See [[definition>>||anchor="HWeatherSensorTypes:"]] for the sensor type.
541 +See [[definition>>||anchor="H"]] for the sensor type.
539 539  
540 -[[image:image-20220624144904-12.png]]
541 541  
544 +|(% rowspan="2" %)Byte3|Bit23|Bit22|Bit21|Bit20|Bit19|Bit18|Bit17|Bit16
545 +| |A4|A3|A2|A1| | |
546 +|(% rowspan="2" %)Byte2|Bit15|Bit14|Bit13|Bit12|Bit11|Bit10|Bit9|Bit8
547 +| | |Solar Radiation|PAR|PM10|PM2.5|(((
548 +Rain
542 542  
550 +Gauge
551 +)))|(((
552 +Air
543 543  
554 +Pressure
555 +)))
556 +|(% rowspan="2" %)Byte1|Bit7|Bit6|Bit5|Bit4|Bit3|Bit2|Bit1|Bit0
557 +|Humidity|Temperature|CO2|(((
558 +Rain/Snow
559 +
560 +Detect
561 +)))|illuminance|(((
562 +Wind
563 +
564 +Direction
565 +)))|Wind Speed|BAT
566 +
544 544  (% style="color:#037691" %)**AT Command:**
545 545  
546 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:377px" %)
547 -|=(% style="width: 157px;" %)**Command Example**|=(% style="width: 130px;" %)**Function**|=(% style="width: 87px;" %)**Response**
548 -|(% style="width:157px" %)AT+STYPE=80221|(% style="width:130px" %)Set sensor types|(% style="width:87px" %)OK
569 +|**Command Example**|**Function**|**Response**
570 +|AT+STYPE=80221|Set sensor types|OK
549 549  
550 550  Eg: The setting command **AT+STYPE=802212** means:
551 551  
552 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:495px" %)
553 -|(% rowspan="2" style="width:57px" %)Byte3|(% style="width:57px" %)Bit23|(% style="width:59px" %)Bit22|(% style="width:56px" %)Bit21|(% style="width:51px" %)Bit20|(% style="width:54px" %)Bit19|(% style="width:54px" %)Bit18|(% style="width:52px" %)Bit17|(% style="width:52px" %)Bit16
554 -|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)0|(% style="width:51px" %)0|(% style="width:54px" %)1|(% style="width:54px" %)0|(% style="width:52px" %)0|(% style="width:52px" %)0
555 -|(% rowspan="2" style="width:57px" %)Byte2|(% style="width:57px" %)Bit15|(% style="width:59px" %)Bit14|(% style="width:56px" %)Bit13|(% style="width:51px" %)Bit12|(% style="width:54px" %)Bit11|(% style="width:54px" %)Bit10|(% style="width:52px" %)Bit9|(% style="width:52px" %)Bit8
556 -|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)0|(% style="width:51px" %)0|(% style="width:54px" %)0|(% style="width:54px" %)0|(% style="width:52px" %)1|(% style="width:52px" %)0
557 -|(% rowspan="2" style="width:57px" %)Byte1|(% style="width:57px" %)Bit7|(% style="width:59px" %)Bit6|(% style="width:56px" %)Bit5|(% style="width:51px" %)Bit4|(% style="width:54px" %)Bit3|(% style="width:54px" %)Bit2|(% style="width:52px" %)Bit1|(% style="width:52px" %)Bit0
558 -|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)1|(% style="width:51px" %)0|(% style="width:54px" %)0|(% style="width:54px" %)0|(% style="width:52px" %)0|(% style="width:52px" %)1
574 +|(% rowspan="2" %)Byte3|Bit23|Bit22|Bit21|Bit20|Bit19|Bit18|Bit17|Bit16
575 +|0|0|0|0|1|0|0|0
576 +|(% rowspan="2" %)Byte2|Bit15|Bit14|Bit13|Bit12|Bit11|Bit10|Bit9|Bit8
577 +|0|0|0|0|0|0|1|0
578 +|(% rowspan="2" %)Byte1|Bit7|Bit6|Bit5|Bit4|Bit3|Bit2|Bit1|Bit0
579 +|0|0|1|0|0|0|0|1
559 559  
560 560  So wsc1-L will upload the following data: Custom Sensor A1, Rain Gauge,CO2,BAT.
561 561  
... ... @@ -566,11 +566,12 @@
566 566  
567 567  (% style="color:red" %)**Note:**
568 568  
569 -~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned.
590 +~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned
570 570  
571 571  
572 572  
573 573  
595 +
574 574  = 4. Power consumption and battery =
575 575  
576 576  == 4.1 Total Power Consumption ==
... ... @@ -583,15 +583,13 @@
583 583  The main process unit WSC1-L is set to LoRaWAN Class C by default. If user want to reduce the power consumption of this unit, user can set it to run in Class A. In Class A mode, WSC1-L will not be to get real-time downlink command from IoT Server.
584 584  
585 585  
608 +
586 586  == 4.3 Battery ==
587 587  
588 -(((
589 -All sensors are only power by external power source. If external power source is off. All sensor won't work.
590 -)))
611 +All sensors are only power by external power source. If external power source is off. All sensor won’t work.
591 591  
592 -(((
613 +
593 593  Main Process Unit WSC1-L is powered by both external power source and internal 1000mAh rechargeable battery. If external power source is off, WSC1-L still runs and can send periodically uplinks, but the sensors value will become invalid.  External power source can recharge the 1000mAh rechargeable battery.
594 -)))
595 595  
596 596  
597 597  
... ... @@ -611,10 +611,6 @@
611 611  * IP Rating: IP65
612 612  * Support default sensors or 3rd party RS485 sensors
613 613  
614 -
615 -
616 -
617 -
618 618  == 5.2 Power Consumption ==
619 619  
620 620  WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA
image-20220624144904-12.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -17.2 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0