Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/04/25 09:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -78,8 +78,6 @@ 78 78 * Cabinet. 79 79 80 80 81 - 82 - 83 83 == 2.2 How it works? == 84 84 85 85 ((( ... ... @@ -98,8 +98,6 @@ 98 98 1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors. 99 99 100 100 101 - 102 - 103 103 == 2.3 Example to use for LoRaWAN network == 104 104 105 105 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. ... ... @@ -158,6 +158,8 @@ 158 158 159 159 160 160 157 + 158 + 161 161 === 2.4.1 Uplink FPORT~=5, Device Status === 162 162 163 163 Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours ... ... @@ -382,6 +382,7 @@ 382 382 These commands only valid for WSC1-L, as below: 383 383 384 384 383 + 385 385 == 3.1 Set Transmit Interval Time == 386 386 387 387 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -401,6 +401,7 @@ 401 401 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 402 402 403 403 403 + 404 404 == 3.2 Set Emergency Mode == 405 405 406 406 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. ... ... @@ -416,6 +416,7 @@ 416 416 * 0xE100 Same as: AT+ALARMMOD=0 417 417 418 418 419 + 419 419 == 3.3 Add or Delete RS485 Sensor == 420 420 421 421 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. ... ... @@ -432,6 +432,7 @@ 432 432 * has_CRC: RS485 Response crc check (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0. 433 433 * timeout: RS485 receive timeout (uint:ms). Device will close receive window after timeout 434 434 436 + 435 435 **Example:** 436 436 437 437 User need to change external sensor use the type code as address code. ... ... @@ -485,6 +485,7 @@ 485 485 * 0xE5FF 486 486 487 487 490 + 488 488 == 3.4 RS485 Test Command == 489 489 490 490 (% style="color:#037691" %)**AT Command:** ... ... @@ -507,6 +507,7 @@ 507 507 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 508 508 509 509 513 + 510 510 == 3.5 RS485 response timeout == 511 511 512 512 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -531,6 +531,7 @@ 531 531 * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds 532 532 533 533 538 + 534 534 == 3.6 Set Sensor Type == 535 535 536 536 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values. ... ... @@ -540,7 +540,6 @@ 540 540 [[image:image-20220624144904-12.png]] 541 541 542 542 543 - 544 544 (% style="color:#037691" %)**AT Command:** 545 545 546 546 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:377px" %) ... ... @@ -611,6 +611,8 @@ 611 611 * IP Rating: IP65 612 612 * Support default sensors or 3rd party RS485 sensors 613 613 618 + 619 + 614 614 == 5.2 Power Consumption == 615 615 616 616 WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA