<
From version < 32.7 >
edited by Xiaoling
on 2022/06/24 14:56
To version < 27.9 >
edited by Xiaoling
on 2022/06/24 14:24
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -67,6 +67,7 @@
67 67  * WSC1-L has an extra 1000mAh back up battery. So it can work even solar panel and storage battery Fails.
68 68  * Weather sensors won’t work if solar panel and storage battery fails.
69 69  
70 +
70 70  (% style="color:red" %)** Notice 2:**
71 71  
72 72  Due to shipment and importation limitation, user is better to purchase below parts locally:
... ... @@ -79,8 +79,6 @@
79 79  
80 80  
81 81  
82 -
83 -
84 84  == 2.2 How it works? ==
85 85  
86 86  (((
... ... @@ -100,8 +100,6 @@
100 100  
101 101  
102 102  
103 -
104 -
105 105  == 2.3 Example to use for LoRaWAN network ==
106 106  
107 107  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -159,8 +159,6 @@
159 159  * Other control command: Use FPORT other than 2.
160 160  
161 161  
162 -
163 -
164 164  === 2.4.1 Uplink FPORT~=5, Device Status ===
165 165  
166 166  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -366,6 +366,7 @@
366 366  * AT Command Connection: See [[FAQ>>||anchor="H7.FAQ"]].
367 367  * LoRaWAN Downlink instruction for different platforms:  [[Use Note for Server>>doc:Main.WebHome]](IoT LoRaWAN Server)
368 368  
364 +
369 369  There are two kinds of commands to configure WSC1-L, they are:
370 370  
371 371  * (% style="color:#4472c4" %)**General Commands**.
... ... @@ -375,6 +375,7 @@
375 375  * General system settings like: uplink interval.
376 376  * LoRaWAN protocol & radio related command.
377 377  
374 +
378 378  They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack((% style="color:red" %)Note~*~*)(%%). These commands can be found on the wiki:  [[End Device Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
379 379  
380 380  (% style="color:red" %)Note~*~*: Please check early user manual if you don’t have v1.8.0 firmware.
... ... @@ -391,9 +391,20 @@
391 391  
392 392  (% style="color:#037691" %)**AT Command: AT+TDC**
393 393  
394 -[[image:image-20220624142619-8.png]]
391 +|**Command Example**|**Function**|**Response**
392 +|AT+TDC?|Show current transmit Interval|(((
393 +30000
395 395  
395 +OK
396 396  
397 +the interval is 30000ms = 30s
398 +)))
399 +|AT+TDC=60000|Set Transmit Interval|(((
400 +OK
401 +
402 +Set transmit interval to 60000ms = 60 seconds
403 +)))
404 +
397 397  (% style="color:#037691" %)**Downlink Command: 0x01**
398 398  
399 399  Format: Command Code (0x01) followed by 3 bytes time value.
... ... @@ -403,24 +403,22 @@
403 403  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
404 404  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
405 405  
406 -
407 -
408 408  == 3.2 Set Emergency Mode ==
409 409  
410 410  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
411 411  
418 +
412 412  (% style="color:#037691" %)**AT Command:**
413 413  
414 -[[image:image-20220624142956-9.png]]
421 +|**Command Example**|**Function**|**Response**
422 +|AT+ALARMMOD=1|Enter emergency mode. Uplink every 1 minute|OK
423 +|AT+ALARMMOD=0|Exit emergency mode. Uplink base on TDC time|OK
415 415  
416 -
417 417  (% style="color:#037691" %)**Downlink Command:**
418 418  
419 419  * 0xE101     Same as: AT+ALARMMOD=1
420 420  * 0xE100     Same as: AT+ALARMMOD=0
421 421  
422 -
423 -
424 424  == 3.3 Add or Delete RS485 Sensor ==
425 425  
426 426  Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors.
... ... @@ -427,33 +427,34 @@
427 427  
428 428  (% style="color:#037691" %)**AT Command: **
429 429  
430 -(% style="color:blue" %)**AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout**
436 +AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout
431 431  
432 -* Type_Code range:  A1 ~~ A4
433 -* Query_Length:  RS485 Query frame length, Value cannot be greater than 10
434 -* Query_Command:  RS485 Query frame data to be sent to sensor, cannot be larger than 10 bytes
435 -* Read_Length:  RS485 response frame length supposed to receive. Max can receive
436 -* Valid_Data:  valid data from RS485 Response, Valid Data will be added to Payload and upload via LoRaWAN.
437 -* has_CRC:  RS485 Response crc check  (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0.
438 -* timeout:  RS485 receive timeout (uint:ms). Device will close receive window after timeout
438 +* Type_Code range: A1 ~~ A4
439 +* Query_Length: RS485 Query frame length, Value cannot be greater than 10
440 +* Query_Command: RS485 Query frame data to be sent to sensor, cannot be larger than 10 bytes
441 +* Read_Length: RS485 response frame length supposed to receive. Max can receive
442 +* Valid_Data: valid data from RS485 Response, Valid Data will be added to Payload and upload via LoRaWAN.
443 +* has_CRC: RS485 Response crc check  (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0.
444 +* timeout: RS485 receive timeout (uint:ms). Device will close receive window after timeout
439 439  
446 +Example:
440 440  
441 -**Example:**
442 -
443 443  User need to change external sensor use the type code as address code.
444 444  
445 445  With a 485 sensor, after correctly changing the address code to A1, the RS485 query frame is shown in the following table:
446 446  
447 -[[image:image-20220624143553-10.png]]
452 +|Address Code|Function Code|(% colspan="2" %)Start Register|(% colspan="2" %)Data Length|CRC Check Low|CRC Check High
453 +|0xA1|0x03|0x00|0x00|0x00|0x01|0x9C|0xAA
454 +| | | | | | | |
448 448  
449 -
450 450  The response frame of the sensor is as follows:
451 451  
452 -[[image:image-20220624143618-11.png]]
458 +|Address Code|Function Code|(% colspan="2" %)Data Length|(% colspan="2" %)Data|CRC Check Low|CRC Check High
459 +|0xA1|0x03|0x00|0x02|0x00|0x0A|0x7C|0xAD
460 +| | | | | | | |
453 453  
462 +Then the following parameters should be:
454 454  
455 -**Then the following parameters should be:**
456 -
457 457  * Address_Code range: A1
458 458  * Query_Length: 8
459 459  * Query_Command: A103000000019CAA
... ... @@ -462,23 +462,21 @@
462 462  * has_CRC: 1
463 463  * timeout: 1500 (Fill in the test according to the actual situation)
464 464  
472 +So the input command is:
465 465  
466 -**So the input command is:**
467 -
468 468  AT+DYSENSOR=A1,8,A103000000019CAA,8,24,1,1500
469 469  
470 470  
471 471  In every sampling. WSC1-L will auto append the sensor segment as per this structure and uplink.
472 472  
473 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:351px" %)
474 -|=(% style="width: 94px;" %)Type Code|=(% style="width: 121px;" %)Length (Bytes)|=(% style="width: 132px;" %)Measured Value
475 -|(% style="width:94px" %)A1|(% style="width:121px" %)2|(% style="width:132px" %)0x000A
479 +|Type Code|Length (Bytes)|Measured Value
480 +|A1|2|0x000A
476 476  
477 -**Related commands:**
482 +Related commands:
478 478  
479 -AT+DYSENSOR=A1,0  ~-~->  Delete 3^^rd^^ party sensor A1.
484 +AT+DYSENSOR=A1,0 > Delete 3^^rd^^ party sensor A1.
480 480  
481 -AT+DYSENSOR  ~-~->  List All 3^^rd^^ Party Sensor. Like below:
486 +AT+DYSENSOR ~-~-> List All 3^^rd^^ Party Sensor. Like below:
482 482  
483 483  
484 484  (% style="color:#037691" %)**Downlink Command:  **
... ... @@ -491,19 +491,16 @@
491 491  
492 492  * 0xE5FF  
493 493  
494 -
495 -
496 496  == 3.4 RS485 Test Command ==
497 497  
498 498  (% style="color:#037691" %)**AT Command:**
499 499  
500 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:474px" %)
501 -|=(% style="width: 159px;" %)**Command Example**|=(% style="width: 227px;" %)**Function**|=(% style="width: 85px;" %)**Response**
502 -|(% style="width:159px" %)AT+RSWRITE=xxxxxx|(% style="width:227px" %)(((
503 +|**Command Example**|**Function**|**Response**
504 +|AT+RSWRITE=xxxxxx|(((
503 503  Send command to 485 sensor
504 504  
505 505  Range : no more than 10 bytes
506 -)))|(% style="width:85px" %)OK
508 +)))|OK
507 507  
508 508  Eg: Send command **01 03 00 00 00 01 84 0A** to 485 sensor
509 509  
... ... @@ -514,8 +514,6 @@
514 514  
515 515  * 0xE20103000001840A     Same as: AT+RSWRITE=0103000001840A
516 516  
517 -
518 -
519 519  == 3.5 RS485 response timeout ==
520 520  
521 521  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -522,15 +522,13 @@
522 522  
523 523  (% style="color:#037691" %)**AT Command:**
524 524  
525 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:433px" %)
526 -|=(% style="width: 157px;" %)**Command Example**|=(% style="width: 188px;" %)**Function**|=(% style="width: 85px;" %)**Response**
527 -|(% style="width:157px" %)AT+DTR=1000|(% style="width:188px" %)(((
525 +|**Command Example**|**Function**|**Response**
526 +|AT+DTR=1000|(((
528 528  Set response timeout to:
529 529  
530 530  Range : 0~~10000
531 -)))|(% style="width:85px" %)OK
530 +)))|OK
532 532  
533 -
534 534  (% style="color:#037691" %)**Downlink Command:**
535 535  
536 536  Format: Command Code (0xE0) followed by 3 bytes time value.
... ... @@ -540,34 +540,49 @@
540 540  * Example 1: Downlink Payload: E0000005 ~/~/ Set Transmit Interval (DTR) = 5 seconds
541 541  * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds
542 542  
543 -
544 -
545 545  == 3.6 Set Sensor Type ==
546 546  
547 547  Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.
548 548  
549 -See [[definition>>||anchor="HWeatherSensorTypes:"]] for the sensor type.
545 +See [[definition>>||anchor="H"]] for the sensor type.
550 550  
551 -[[image:image-20220624144904-12.png]]
552 552  
548 +|(% rowspan="2" %)Byte3|Bit23|Bit22|Bit21|Bit20|Bit19|Bit18|Bit17|Bit16
549 +| |A4|A3|A2|A1| | |
550 +|(% rowspan="2" %)Byte2|Bit15|Bit14|Bit13|Bit12|Bit11|Bit10|Bit9|Bit8
551 +| | |Solar Radiation|PAR|PM10|PM2.5|(((
552 +Rain
553 553  
554 +Gauge
555 +)))|(((
556 +Air
554 554  
555 -(% style="color:#037691" %)**AT Command:**
558 +Pressure
559 +)))
560 +|(% rowspan="2" %)Byte1|Bit7|Bit6|Bit5|Bit4|Bit3|Bit2|Bit1|Bit0
561 +|Humidity|Temperature|CO2|(((
562 +Rain/Snow
556 556  
557 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:377px" %)
558 -|=(% style="width: 157px;" %)**Command Example**|=(% style="width: 130px;" %)**Function**|=(% style="width: 87px;" %)**Response**
559 -|(% style="width:157px" %)AT+STYPE=80221|(% style="width:130px" %)Set sensor types|(% style="width:87px" %)OK
564 +Detect
565 +)))|illuminance|(((
566 +Wind
560 560  
568 +Direction
569 +)))|Wind Speed|BAT
561 561  
571 +(% style="color:#037691" %)**AT Command:**
572 +
573 +|**Command Example**|**Function**|**Response**
574 +|AT+STYPE=80221|Set sensor types|OK
575 +
562 562  Eg: The setting command **AT+STYPE=802212** means:
563 563  
564 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:495px" %)
565 -|(% rowspan="2" style="width:57px" %)Byte3|(% style="width:57px" %)Bit23|(% style="width:59px" %)Bit22|(% style="width:56px" %)Bit21|(% style="width:51px" %)Bit20|(% style="width:54px" %)Bit19|(% style="width:54px" %)Bit18|(% style="width:52px" %)Bit17|(% style="width:52px" %)Bit16
566 -|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)0|(% style="width:51px" %)0|(% style="width:54px" %)1|(% style="width:54px" %)0|(% style="width:52px" %)0|(% style="width:52px" %)0
567 -|(% rowspan="2" style="width:57px" %)Byte2|(% style="width:57px" %)Bit15|(% style="width:59px" %)Bit14|(% style="width:56px" %)Bit13|(% style="width:51px" %)Bit12|(% style="width:54px" %)Bit11|(% style="width:54px" %)Bit10|(% style="width:52px" %)Bit9|(% style="width:52px" %)Bit8
568 -|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)0|(% style="width:51px" %)0|(% style="width:54px" %)0|(% style="width:54px" %)0|(% style="width:52px" %)1|(% style="width:52px" %)0
569 -|(% rowspan="2" style="width:57px" %)Byte1|(% style="width:57px" %)Bit7|(% style="width:59px" %)Bit6|(% style="width:56px" %)Bit5|(% style="width:51px" %)Bit4|(% style="width:54px" %)Bit3|(% style="width:54px" %)Bit2|(% style="width:52px" %)Bit1|(% style="width:52px" %)Bit0
570 -|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)1|(% style="width:51px" %)0|(% style="width:54px" %)0|(% style="width:54px" %)0|(% style="width:52px" %)0|(% style="width:52px" %)1
578 +|(% rowspan="2" %)Byte3|Bit23|Bit22|Bit21|Bit20|Bit19|Bit18|Bit17|Bit16
579 +|0|0|0|0|1|0|0|0
580 +|(% rowspan="2" %)Byte2|Bit15|Bit14|Bit13|Bit12|Bit11|Bit10|Bit9|Bit8
581 +|0|0|0|0|0|0|1|0
582 +|(% rowspan="2" %)Byte1|Bit7|Bit6|Bit5|Bit4|Bit3|Bit2|Bit1|Bit0
583 +|0|0|1|0|0|0|0|1
571 571  
572 572  So wsc1-L will upload the following data: Custom Sensor A1, Rain Gauge,CO2,BAT.
573 573  
... ... @@ -578,11 +578,12 @@
578 578  
579 579  (% style="color:red" %)**Note:**
580 580  
581 -~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned.
594 +~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned
582 582  
583 583  
584 584  
585 585  
599 +
586 586  = 4. Power consumption and battery =
587 587  
588 588  == 4.1 Total Power Consumption ==
image-20220624142619-8.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -12.5 KB
Content
image-20220624142956-9.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -9.2 KB
Content
image-20220624143553-10.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -6.7 KB
Content
image-20220624143618-11.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -6.3 KB
Content
image-20220624144904-12.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -17.2 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0