Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/04/25 09:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -80,7 +80,6 @@ 80 80 81 81 82 82 83 - 84 84 == 2.2 How it works? == 85 85 86 86 ((( ... ... @@ -101,7 +101,6 @@ 101 101 102 102 103 103 104 - 105 105 == 2.3 Example to use for LoRaWAN network == 106 106 107 107 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. ... ... @@ -160,7 +160,6 @@ 160 160 161 161 162 162 163 - 164 164 === 2.4.1 Uplink FPORT~=5, Device Status === 165 165 166 166 Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours ... ... @@ -385,6 +385,7 @@ 385 385 These commands only valid for WSC1-L, as below: 386 386 387 387 385 + 388 388 == 3.1 Set Transmit Interval Time == 389 389 390 390 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -405,6 +405,8 @@ 405 405 406 406 407 407 406 + 407 + 408 408 == 3.2 Set Emergency Mode == 409 409 410 410 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. ... ... @@ -421,6 +421,8 @@ 421 421 422 422 423 423 424 + 425 + 424 424 == 3.3 Add or Delete RS485 Sensor == 425 425 426 426 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. ... ... @@ -437,7 +437,6 @@ 437 437 * has_CRC: RS485 Response crc check (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0. 438 438 * timeout: RS485 receive timeout (uint:ms). Device will close receive window after timeout 439 439 440 - 441 441 **Example:** 442 442 443 443 User need to change external sensor use the type code as address code. ... ... @@ -462,7 +462,6 @@ 462 462 * has_CRC: 1 463 463 * timeout: 1500 (Fill in the test according to the actual situation) 464 464 465 - 466 466 **So the input command is:** 467 467 468 468 AT+DYSENSOR=A1,8,A103000000019CAA,8,24,1,1500 ... ... @@ -493,6 +493,8 @@ 493 493 494 494 495 495 496 + 497 + 496 496 == 3.4 RS485 Test Command == 497 497 498 498 (% style="color:#037691" %)**AT Command:** ... ... @@ -516,6 +516,8 @@ 516 516 517 517 518 518 521 + 522 + 519 519 == 3.5 RS485 response timeout == 520 520 521 521 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -530,7 +530,6 @@ 530 530 Range : 0~~10000 531 531 )))|(% style="width:85px" %)OK 532 532 533 - 534 534 (% style="color:#037691" %)**Downlink Command:** 535 535 536 536 Format: Command Code (0xE0) followed by 3 bytes time value. ... ... @@ -542,11 +542,13 @@ 542 542 543 543 544 544 548 + 549 + 545 545 == 3.6 Set Sensor Type == 546 546 547 547 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values. 548 548 549 -See [[definition>>||anchor="H"]] for the sensor type. 554 +See [[definition>>||anchor="HWeatherSensorTypes:"]] for the sensor type. 550 550 551 551 [[image:image-20220624144904-12.png]] 552 552 ... ... @@ -558,7 +558,6 @@ 558 558 |=(% style="width: 157px;" %)**Command Example**|=(% style="width: 130px;" %)**Function**|=(% style="width: 87px;" %)**Response** 559 559 |(% style="width:157px" %)AT+STYPE=80221|(% style="width:130px" %)Set sensor types|(% style="width:87px" %)OK 560 560 561 - 562 562 Eg: The setting command **AT+STYPE=802212** means: 563 563 564 564 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:495px" %) ... ... @@ -595,13 +595,15 @@ 595 595 The main process unit WSC1-L is set to LoRaWAN Class C by default. If user want to reduce the power consumption of this unit, user can set it to run in Class A. In Class A mode, WSC1-L will not be to get real-time downlink command from IoT Server. 596 596 597 597 598 - 599 599 == 4.3 Battery == 600 600 601 -All sensors are only power by external power source. If external power source is off. All sensor won’t work. 604 +((( 605 +All sensors are only power by external power source. If external power source is off. All sensor won't work. 606 +))) 602 602 603 - 608 +((( 604 604 Main Process Unit WSC1-L is powered by both external power source and internal 1000mAh rechargeable battery. If external power source is off, WSC1-L still runs and can send periodically uplinks, but the sensors value will become invalid. External power source can recharge the 1000mAh rechargeable battery. 610 +))) 605 605 606 606 607 607 ... ... @@ -621,6 +621,10 @@ 621 621 * IP Rating: IP65 622 622 * Support default sensors or 3rd party RS485 sensors 623 623 630 + 631 + 632 + 633 + 624 624 == 5.2 Power Consumption == 625 625 626 626 WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA