Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/04/25 09:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -150,6 +150,8 @@ 150 150 * Valid Sensor Value: Use FPORT=2 151 151 * Other control command: Use FPORT other than 2. 152 152 153 + 154 + 153 153 === 2.4.1 Uplink FPORT~=5, Device Status === 154 154 155 155 Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours ... ... @@ -392,8 +392,6 @@ 392 392 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 393 393 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 394 394 395 - 396 - 397 397 == 3.2 Set Emergency Mode == 398 398 399 399 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. ... ... @@ -408,8 +408,6 @@ 408 408 * 0xE101 Same as: AT+ALARMMOD=1 409 409 * 0xE100 Same as: AT+ALARMMOD=0 410 410 411 - 412 - 413 413 == 3.3 Add or Delete RS485 Sensor == 414 414 415 415 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. ... ... @@ -426,7 +426,6 @@ 426 426 * has_CRC: RS485 Response crc check (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0. 427 427 * timeout: RS485 receive timeout (uint:ms). Device will close receive window after timeout 428 428 429 - 430 430 **Example:** 431 431 432 432 User need to change external sensor use the type code as address code. ... ... @@ -451,7 +451,6 @@ 451 451 * has_CRC: 1 452 452 * timeout: 1500 (Fill in the test according to the actual situation) 453 453 454 - 455 455 **So the input command is:** 456 456 457 457 AT+DYSENSOR=A1,8,A103000000019CAA,8,24,1,1500 ... ... @@ -480,8 +480,6 @@ 480 480 481 481 * 0xE5FF 482 482 483 - 484 - 485 485 == 3.4 RS485 Test Command == 486 486 487 487 (% style="color:#037691" %)**AT Command:** ... ... @@ -503,8 +503,6 @@ 503 503 504 504 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 505 505 506 - 507 - 508 508 == 3.5 RS485 response timeout == 509 509 510 510 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -519,7 +519,6 @@ 519 519 Range : 0~~10000 520 520 )))|(% style="width:85px" %)OK 521 521 522 - 523 523 (% style="color:#037691" %)**Downlink Command:** 524 524 525 525 Format: Command Code (0xE0) followed by 3 bytes time value. ... ... @@ -529,18 +529,15 @@ 529 529 * Example 1: Downlink Payload: E0000005 ~/~/ Set Transmit Interval (DTR) = 5 seconds 530 530 * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds 531 531 532 - 533 - 534 534 == 3.6 Set Sensor Type == 535 535 536 536 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values. 537 537 538 -See [[definition>>||anchor="H"]] for the sensor type. 527 +See [[definition>>||anchor="HWeatherSensorTypes:"]] for the sensor type. 539 539 540 540 [[image:image-20220624144904-12.png]] 541 541 542 542 543 - 544 544 (% style="color:#037691" %)**AT Command:** 545 545 546 546 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:377px" %) ... ... @@ -547,7 +547,6 @@ 547 547 |=(% style="width: 157px;" %)**Command Example**|=(% style="width: 130px;" %)**Function**|=(% style="width: 87px;" %)**Response** 548 548 |(% style="width:157px" %)AT+STYPE=80221|(% style="width:130px" %)Set sensor types|(% style="width:87px" %)OK 549 549 550 - 551 551 Eg: The setting command **AT+STYPE=802212** means: 552 552 553 553 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:495px" %) ... ... @@ -572,7 +572,6 @@ 572 572 573 573 574 574 575 - 576 576 = 4. Power consumption and battery = 577 577 578 578 == 4.1 Total Power Consumption == ... ... @@ -585,16 +585,17 @@ 585 585 The main process unit WSC1-L is set to LoRaWAN Class C by default. If user want to reduce the power consumption of this unit, user can set it to run in Class A. In Class A mode, WSC1-L will not be to get real-time downlink command from IoT Server. 586 586 587 587 588 - 589 589 == 4.3 Battery == 590 590 591 -All sensors are only power by external power source. If external power source is off. All sensor won’t work. 576 +((( 577 +All sensors are only power by external power source. If external power source is off. All sensor won't work. 578 +))) 592 592 593 - 580 +((( 594 594 Main Process Unit WSC1-L is powered by both external power source and internal 1000mAh rechargeable battery. If external power source is off, WSC1-L still runs and can send periodically uplinks, but the sensors value will become invalid. External power source can recharge the 1000mAh rechargeable battery. 582 +))) 595 595 596 596 597 - 598 598 = 5. Main Process Unit WSC1-L = 599 599 600 600 == 5.1 Features == ... ... @@ -616,7 +616,6 @@ 616 616 WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA 617 617 618 618 619 - 620 620 == 5.3 Storage & Operation Temperature == 621 621 622 622 -20°C to +60°C ... ... @@ -624,7 +624,7 @@ 624 624 625 625 == 5.4 Pin Mapping == 626 626 627 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image004.png]]613 +[[image:1656054149793-239.png]] 628 628 629 629 630 630 == 5.5 Mechanical == ... ... @@ -632,14 +632,12 @@ 632 632 Refer LSn50v2 enclosure drawing in: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/>>url:https://www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/]] 633 633 634 634 635 - 636 - 637 637 == 5.6 Connect to RS485 Sensors == 638 638 639 639 WSC1-L includes a RS485 converter PCB. Which help it easy to connect multiply RS485 sensors. Below is the photo for reference. 640 640 641 641 642 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image018.png]]626 +[[image:1656054389031-379.png]] 643 643 644 644 645 645 Hardware Design for the Converter Board please see: ... ... @@ -647,37 +647,22 @@ 647 647 [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Weather_Station/RS485_Converter_Board/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Weather_Station/RS485_Converter_Board/]] 648 648 649 649 650 - 651 - 652 - 653 653 = 6. Weather Sensors = 654 654 655 655 == 6.1 Rain Gauge ~-~- WSS-01 == 656 656 638 + 657 657 WSS-01 RS485 Rain Gauge is used in meteorology and hydrology to gather and measure the amount of liquid precipitation (mainly rainfall) over an area. 658 658 641 +WSS-01 uses a tipping bucket to detect rainfall. The tipping bucket use 3D streamline shape to make sure it works smoothly and is easy to clean. 659 659 660 -WSS-01 usesatippingbucket todetectrainfall. The tippingbucket use3Dstreamline643 +WSS-01 is designed to support the Dragino Weather station solution. Users only need to connect WSS-01 RS485 interface to WSC1-L. The weather station main processor WSC1-L can detect and upload the rainfall to the IoT Server via wireless LoRaWAN protocol 661 661 662 - shape tomake sureitworkssmoothlyandiseasy to clean.645 +The tipping bucket of WSS-01 is adjusted to the best angle. When installation, user only needs to screw up and adjust the bottom horizontally. 663 663 664 - 665 -WSS-01 is designed to support the Dragino Weather station solution. 666 - 667 -Users only need to connect WSS-01 RS485 interface to WSC1-L. The weather station main 668 - 669 -processor WSC1-L can detect and upload the rainfall to the IoT Server via wireless LoRaWAN protocol 670 - 671 - 672 -The tipping bucket of WSS-01 is adjusted to the best angle. When installation, user only needs 673 - 674 -to screw up and adjust the bottom horizontally. 675 - 676 - 677 677 WSS-01 package includes screw which can be installed to ground. If user want to install WSS-01 on pole, they can purchase WS-K2 bracket kit. 678 678 679 679 680 - 681 681 === 6.1.1 Feature === 682 682 683 683 * RS485 Rain Gauge ... ... @@ -686,6 +686,9 @@ 686 686 * ABS enclosure. 687 687 * Horizontal adjustable. 688 688 658 + 659 + 660 + 689 689 === 6.1.2 Specification === 690 690 691 691 * Resolution: 0.2mm ... ... @@ -697,6 +697,9 @@ 697 697 * Working Humidity: <100% (no dewing) 698 698 * Power Consumption: 4mA @ 12v. 699 699 672 + 673 + 674 + 700 700 === 6.1.3 Dimension === 701 701 702 702 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image019.jpg||alt="c2d3aee592ccc873bea6dd891451df2"]] ... ... @@ -758,6 +758,9 @@ 758 758 * RS485 wind speed / direction sensor 759 759 * PC enclosure, resist corrosion 760 760 736 + 737 + 738 + 761 761 === 6.2.2 Specification === 762 762 763 763 * Wind speed range: 0 ~~ 30m/s, (always show 30m/s for higher speed) ... ... @@ -771,6 +771,9 @@ 771 771 * Power Consumption: 13mA ~~ 12v. 772 772 * Cable Length: 2 meters 773 773 752 + 753 + 754 + 774 774 === 6.2.3 Dimension === 775 775 776 776 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.jpg]][[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.jpg]] ... ... @@ -828,6 +828,9 @@ 828 828 * NDIR to measure CO2 with Internal Temperature Compensation 829 829 * Laser Beam Scattering to PM2.5 and PM10 830 830 812 + 813 + 814 + 831 831 === 6.3.2 Specification === 832 832 833 833 * CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃) ... ... @@ -845,6 +845,9 @@ 845 845 ** CO2: 0~95%RH 846 846 * Power Consumption: 50mA@ 12v. 847 847 832 + 833 + 834 + 848 848 === 6.3.3 Dimension === 849 849 850 850 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]] ... ... @@ -890,6 +890,9 @@ 890 890 * Surface heating to dry 891 891 * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion 892 892 880 + 881 + 882 + 893 893 === 6.4.2 Specification === 894 894 895 895 * Detect if there is rain or snow ... ... @@ -901,6 +901,9 @@ 901 901 ** No heating: 12mA @ 12v, 902 902 ** heating: 94ma @ 12v. 903 903 894 + 895 + 896 + 904 904 === 6.4.3 Dimension === 905 905 906 906 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image031.png]] ... ... @@ -950,6 +950,9 @@ 950 950 951 951 * RS485 Temperature, Humidity, Illuminance, Pressure sensor 952 952 946 + 947 + 948 + 953 953 === 6.5.2 Specification === 954 954 955 955 * Input Power: DC 12 ~~ 24v ... ... @@ -974,6 +974,9 @@ 974 974 * Working Humidity: 10~90%RH 975 975 * Power Consumption: 4mA @ 12v 976 976 973 + 974 + 975 + 977 977 === 6.5.3 Dimension === 978 978 979 979 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image034.jpg]] ... ... @@ -1019,6 +1019,9 @@ 1019 1019 * Measure Total Radiation between 0.3~3μm(300~3000nm) 1020 1020 * Measure Reflected Radiation if sense area towards ground. 1021 1021 1021 + 1022 + 1023 + 1022 1022 === 6.6.2 Specification === 1023 1023 1024 1024 * Input Power: DC 5 ~~ 24v ... ... @@ -1034,6 +1034,9 @@ 1034 1034 * Working Humidity: 10~90%RH 1035 1035 * Power Consumption: 4mA @ 12v 1036 1036 1039 + 1040 + 1041 + 1037 1037 === 6.6.3 Dimension === 1038 1038 1039 1039 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] ... ... @@ -1091,6 +1091,9 @@ 1091 1091 * Working Humidity: 10~90%RH 1092 1092 * Power Consumption: 3mA @ 12v 1093 1093 1099 + 1100 + 1101 + 1094 1094 === 6.7.3 Dimension === 1095 1095 1096 1096 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] ... ... @@ -1160,19 +1160,22 @@ 1160 1160 1161 1161 == 9.1 Main Process Unit == 1162 1162 1163 -Part Number: **WSC1-L-XX** 1171 +Part Number: (% style="color:blue" %)**WSC1-L-XX** 1164 1164 1165 -**XX**: The default frequency band 1173 +(% style="color:blue" %)**XX**(%%): The default frequency band 1166 1166 1167 -* **AS923**: LoRaWAN AS923 band 1168 -* **AU915**: LoRaWAN AU915 band 1169 -* **EU433**: LoRaWAN EU433 band 1170 -* **EU868**: LoRaWAN EU868 band 1171 -* **KR920**: LoRaWAN KR920 band 1172 -* **US915**: LoRaWAN US915 band 1173 -* **IN865**: LoRaWAN IN865 band 1174 -* **CN470**: LoRaWAN CN470 band 1175 +* (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 1176 +* (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band 1177 +* (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band 1178 +* (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band 1179 +* (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band 1180 +* (% style="color:red" %)**US915**(%%): LoRaWAN US915 band 1181 +* (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1182 +* (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1175 1175 1184 + 1185 + 1186 + 1176 1176 == 9.2 Sensors == 1177 1177 1178 1178 |**Sensor Model**|**Part Number** ... ... @@ -1185,6 +1185,7 @@ 1185 1185 |**Total Solar Radiation Sensor**|WSS-06 1186 1186 |**PAR (Photosynthetically Available Radiation)**|WSS-07 1187 1187 1199 + 1188 1188 = 10. Support = 1189 1189 1190 1190 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
- 1656054149793-239.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +492.6 KB - Content
- 1656054389031-379.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content