Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Mengting Qiu on 2025/06/10 18:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -77,6 +77,7 @@ 77 77 * Mounting Kit includes pole and mast assembly. Each weather sensor has it’s own mounting assembly, user can check the sensor section in this manual. 78 78 * Cabinet. 79 79 80 + 80 80 == 2.2 How it works? == 81 81 82 82 ((( ... ... @@ -94,6 +94,7 @@ 94 94 1. WSC1-L will auto scan available weather sensors when power on or reboot. 95 95 1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors. 96 96 98 + 97 97 == 2.3 Example to use for LoRaWAN network == 98 98 99 99 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. ... ... @@ -150,6 +150,10 @@ 150 150 * Valid Sensor Value: Use FPORT=2 151 151 * Other control command: Use FPORT other than 2. 152 152 155 + 156 + 157 + 158 + 153 153 === 2.4.1 Uplink FPORT~=5, Device Status === 154 154 155 155 Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours ... ... @@ -374,6 +374,7 @@ 374 374 These commands only valid for WSC1-L, as below: 375 375 376 376 383 + 377 377 == 3.1 Set Transmit Interval Time == 378 378 379 379 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -451,7 +451,6 @@ 451 451 * has_CRC: 1 452 452 * timeout: 1500 (Fill in the test according to the actual situation) 453 453 454 - 455 455 **So the input command is:** 456 456 457 457 AT+DYSENSOR=A1,8,A103000000019CAA,8,24,1,1500 ... ... @@ -519,7 +519,6 @@ 519 519 Range : 0~~10000 520 520 )))|(% style="width:85px" %)OK 521 521 522 - 523 523 (% style="color:#037691" %)**Downlink Command:** 524 524 525 525 Format: Command Code (0xE0) followed by 3 bytes time value. ... ... @@ -535,12 +535,11 @@ 535 535 536 536 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values. 537 537 538 -See [[definition>>||anchor="H"]] for the sensor type. 543 +See [[definition>>||anchor="HWeatherSensorTypes:"]] for the sensor type. 539 539 540 540 [[image:image-20220624144904-12.png]] 541 541 542 542 543 - 544 544 (% style="color:#037691" %)**AT Command:** 545 545 546 546 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:377px" %) ... ... @@ -547,7 +547,6 @@ 547 547 |=(% style="width: 157px;" %)**Command Example**|=(% style="width: 130px;" %)**Function**|=(% style="width: 87px;" %)**Response** 548 548 |(% style="width:157px" %)AT+STYPE=80221|(% style="width:130px" %)Set sensor types|(% style="width:87px" %)OK 549 549 550 - 551 551 Eg: The setting command **AT+STYPE=802212** means: 552 552 553 553 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:495px" %) ... ... @@ -572,7 +572,6 @@ 572 572 573 573 574 574 575 - 576 576 = 4. Power consumption and battery = 577 577 578 578 == 4.1 Total Power Consumption == ... ... @@ -585,13 +585,15 @@ 585 585 The main process unit WSC1-L is set to LoRaWAN Class C by default. If user want to reduce the power consumption of this unit, user can set it to run in Class A. In Class A mode, WSC1-L will not be to get real-time downlink command from IoT Server. 586 586 587 587 588 - 589 589 == 4.3 Battery == 590 590 591 -All sensors are only power by external power source. If external power source is off. All sensor won’t work. 592 +((( 593 +All sensors are only power by external power source. If external power source is off. All sensor won't work. 594 +))) 592 592 593 - 596 +((( 594 594 Main Process Unit WSC1-L is powered by both external power source and internal 1000mAh rechargeable battery. If external power source is off, WSC1-L still runs and can send periodically uplinks, but the sensors value will become invalid. External power source can recharge the 1000mAh rechargeable battery. 598 +))) 595 595 596 596 597 597 ... ... @@ -611,6 +611,8 @@ 611 611 * IP Rating: IP65 612 612 * Support default sensors or 3rd party RS485 sensors 613 613 618 + 619 + 614 614 == 5.2 Power Consumption == 615 615 616 616 WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA