Last modified by Mengting Qiu on 2025/06/10 18:53

From version 32.5
edited by Xiaoling
on 2022/06/24 14:52
Change comment: There is no comment for this version
To version 32.12
edited by Xiaoling
on 2022/06/24 15:00
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -77,6 +77,7 @@
77 77  * Mounting Kit includes pole and mast assembly. Each weather sensor has it’s own mounting assembly, user can check the sensor section in this manual.
78 78  * Cabinet.
79 79  
80 +
80 80  == 2.2 How it works? ==
81 81  
82 82  (((
... ... @@ -94,6 +94,7 @@
94 94  1. WSC1-L will auto scan available weather sensors when power on or reboot.
95 95  1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors.
96 96  
98 +
97 97  == 2.3 Example to use for LoRaWAN network ==
98 98  
99 99  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -150,6 +150,10 @@
150 150  * Valid Sensor Value: Use FPORT=2
151 151  * Other control command: Use FPORT other than 2.
152 152  
155 +
156 +
157 +
158 +
153 153  === 2.4.1 Uplink FPORT~=5, Device Status ===
154 154  
155 155  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -374,6 +374,7 @@
374 374  These commands only valid for WSC1-L, as below:
375 375  
376 376  
383 +
377 377  == 3.1 Set Transmit Interval Time ==
378 378  
379 379  Feature: Change LoRaWAN End Node Transmit Interval.
... ... @@ -451,7 +451,6 @@
451 451  * has_CRC: 1
452 452  * timeout: 1500 (Fill in the test according to the actual situation)
453 453  
454 -
455 455  **So the input command is:**
456 456  
457 457  AT+DYSENSOR=A1,8,A103000000019CAA,8,24,1,1500
... ... @@ -519,7 +519,6 @@
519 519  Range : 0~~10000
520 520  )))|(% style="width:85px" %)OK
521 521  
522 -
523 523  (% style="color:#037691" %)**Downlink Command:**
524 524  
525 525  Format: Command Code (0xE0) followed by 3 bytes time value.
... ... @@ -535,12 +535,11 @@
535 535  
536 536  Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.
537 537  
538 -See [[definition>>||anchor="H"]] for the sensor type.
543 +See [[definition>>||anchor="HWeatherSensorTypes:"]] for the sensor type.
539 539  
540 540  [[image:image-20220624144904-12.png]]
541 541  
542 542  
543 -
544 544  (% style="color:#037691" %)**AT Command:**
545 545  
546 546  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:377px" %)
... ... @@ -547,7 +547,6 @@
547 547  |=(% style="width: 157px;" %)**Command Example**|=(% style="width: 130px;" %)**Function**|=(% style="width: 87px;" %)**Response**
548 548  |(% style="width:157px" %)AT+STYPE=80221|(% style="width:130px" %)Set sensor types|(% style="width:87px" %)OK
549 549  
550 -
551 551  Eg: The setting command **AT+STYPE=802212** means:
552 552  
553 553  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:495px" %)
... ... @@ -572,7 +572,6 @@
572 572  
573 573  
574 574  
575 -
576 576  = 4. Power consumption and battery =
577 577  
578 578  == 4.1 Total Power Consumption ==
... ... @@ -585,13 +585,15 @@
585 585  The main process unit WSC1-L is set to LoRaWAN Class C by default. If user want to reduce the power consumption of this unit, user can set it to run in Class A. In Class A mode, WSC1-L will not be to get real-time downlink command from IoT Server.
586 586  
587 587  
588 -
589 589  == 4.3 Battery ==
590 590  
591 -All sensors are only power by external power source. If external power source is off. All sensor won’t work.
592 +(((
593 +All sensors are only power by external power source. If external power source is off. All sensor won't work.
594 +)))
592 592  
593 -
596 +(((
594 594  Main Process Unit WSC1-L is powered by both external power source and internal 1000mAh rechargeable battery. If external power source is off, WSC1-L still runs and can send periodically uplinks, but the sensors value will become invalid.  External power source can recharge the 1000mAh rechargeable battery.
598 +)))
595 595  
596 596  
597 597  
... ... @@ -611,6 +611,8 @@
611 611  * IP Rating: IP65
612 612  * Support default sensors or 3rd party RS485 sensors
613 613  
618 +
619 +
614 614  == 5.2 Power Consumption ==
615 615  
616 616  WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA