Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/04/25 09:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -77,6 +77,9 @@ 77 77 * Mounting Kit includes pole and mast assembly. Each weather sensor has it’s own mounting assembly, user can check the sensor section in this manual. 78 78 * Cabinet. 79 79 80 + 81 + 82 + 80 80 == 2.2 How it works? == 81 81 82 82 ((( ... ... @@ -94,6 +94,9 @@ 94 94 1. WSC1-L will auto scan available weather sensors when power on or reboot. 95 95 1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors. 96 96 100 + 101 + 102 + 97 97 == 2.3 Example to use for LoRaWAN network == 98 98 99 99 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. ... ... @@ -150,6 +150,8 @@ 150 150 * Valid Sensor Value: Use FPORT=2 151 151 * Other control command: Use FPORT other than 2. 152 152 159 + 160 + 153 153 === 2.4.1 Uplink FPORT~=5, Device Status === 154 154 155 155 Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours ... ... @@ -393,7 +393,6 @@ 393 393 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 394 394 395 395 396 - 397 397 == 3.2 Set Emergency Mode == 398 398 399 399 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. ... ... @@ -409,7 +409,6 @@ 409 409 * 0xE100 Same as: AT+ALARMMOD=0 410 410 411 411 412 - 413 413 == 3.3 Add or Delete RS485 Sensor == 414 414 415 415 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. ... ... @@ -426,7 +426,6 @@ 426 426 * has_CRC: RS485 Response crc check (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0. 427 427 * timeout: RS485 receive timeout (uint:ms). Device will close receive window after timeout 428 428 429 - 430 430 **Example:** 431 431 432 432 User need to change external sensor use the type code as address code. ... ... @@ -451,7 +451,6 @@ 451 451 * has_CRC: 1 452 452 * timeout: 1500 (Fill in the test according to the actual situation) 453 453 454 - 455 455 **So the input command is:** 456 456 457 457 AT+DYSENSOR=A1,8,A103000000019CAA,8,24,1,1500 ... ... @@ -481,7 +481,6 @@ 481 481 * 0xE5FF 482 482 483 483 484 - 485 485 == 3.4 RS485 Test Command == 486 486 487 487 (% style="color:#037691" %)**AT Command:** ... ... @@ -504,7 +504,6 @@ 504 504 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 505 505 506 506 507 - 508 508 == 3.5 RS485 response timeout == 509 509 510 510 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -519,7 +519,6 @@ 519 519 Range : 0~~10000 520 520 )))|(% style="width:85px" %)OK 521 521 522 - 523 523 (% style="color:#037691" %)**Downlink Command:** 524 524 525 525 Format: Command Code (0xE0) followed by 3 bytes time value. ... ... @@ -530,12 +530,11 @@ 530 530 * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds 531 531 532 532 533 - 534 534 == 3.6 Set Sensor Type == 535 535 536 536 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values. 537 537 538 -See [[definition>>||anchor="H"]] for the sensor type. 538 +See [[definition>>||anchor="HWeatherSensorTypes:"]] for the sensor type. 539 539 540 540 [[image:image-20220624144904-12.png]] 541 541 ... ... @@ -547,7 +547,6 @@ 547 547 |=(% style="width: 157px;" %)**Command Example**|=(% style="width: 130px;" %)**Function**|=(% style="width: 87px;" %)**Response** 548 548 |(% style="width:157px" %)AT+STYPE=80221|(% style="width:130px" %)Set sensor types|(% style="width:87px" %)OK 549 549 550 - 551 551 Eg: The setting command **AT+STYPE=802212** means: 552 552 553 553 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:495px" %) ... ... @@ -567,12 +567,11 @@ 567 567 568 568 (% style="color:red" %)**Note:** 569 569 570 -~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned 569 +~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned. 571 571 572 572 573 573 574 574 575 - 576 576 = 4. Power consumption and battery = 577 577 578 578 == 4.1 Total Power Consumption == ... ... @@ -585,13 +585,15 @@ 585 585 The main process unit WSC1-L is set to LoRaWAN Class C by default. If user want to reduce the power consumption of this unit, user can set it to run in Class A. In Class A mode, WSC1-L will not be to get real-time downlink command from IoT Server. 586 586 587 587 588 - 589 589 == 4.3 Battery == 590 590 591 -All sensors are only power by external power source. If external power source is off. All sensor won’t work. 588 +((( 589 +All sensors are only power by external power source. If external power source is off. All sensor won't work. 590 +))) 592 592 593 - 592 +((( 594 594 Main Process Unit WSC1-L is powered by both external power source and internal 1000mAh rechargeable battery. If external power source is off, WSC1-L still runs and can send periodically uplinks, but the sensors value will become invalid. External power source can recharge the 1000mAh rechargeable battery. 594 +))) 595 595 596 596 597 597 ... ... @@ -611,6 +611,10 @@ 611 611 * IP Rating: IP65 612 612 * Support default sensors or 3rd party RS485 sensors 613 613 614 + 615 + 616 + 617 + 614 614 == 5.2 Power Consumption == 615 615 616 616 WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA