... ... @@ -77,6 +77,7 @@
77 77  * Mounting Kit includes pole and mast assembly. Each weather sensor has it’s own mounting assembly, user can check the sensor section in this manual.
78 78  * Cabinet.
79 79  
80 +
80 80  == 2.2 How it works? ==
81 81  
82 82  (((
... ... @@ -94,6 +94,7 @@
94 94  1. WSC1-L will auto scan available weather sensors when power on or reboot.
95 95  1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors.
96 96  
98 +
97 97  == 2.3 Example to use for LoRaWAN network ==
98 98  
99 99  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -150,6 +150,10 @@
150 150  * Valid Sensor Value: Use FPORT=2
151 151  * Other control command: Use FPORT other than 2.
152 152  
155 +
156 +
157 +
158 +
153 153  === 2.4.1 Uplink FPORT~=5, Device Status ===
154 154  
155 155  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -374,6 +374,7 @@
374 374  These commands only valid for WSC1-L, as below:
375 375  
376 376  
383 +
377 377  == 3.1 Set Transmit Interval Time ==
378 378  
379 379  Feature: Change LoRaWAN End Node Transmit Interval.
... ... @@ -451,7 +451,6 @@
451 451  * has_CRC: 1
452 452  * timeout: 1500 (Fill in the test according to the actual situation)
453 453  
454 -
455 455  **So the input command is:**
456 456  
457 457  AT+DYSENSOR=A1,8,A103000000019CAA,8,24,1,1500
... ... @@ -519,7 +519,6 @@
519 519  Range : 0~~10000
520 520  )))|(% style="width:85px" %)OK
521 521  
522 -
523 523  (% style="color:#037691" %)**Downlink Command:**
524 524  
525 525  Format: Command Code (0xE0) followed by 3 bytes time value.
... ... @@ -535,12 +535,11 @@
535 535  
536 536  Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.
537 537  
538 -See [[definition>>||anchor="H"]] for the sensor type.
543 +See [[definition>>||anchor="HWeatherSensorTypes:"]] for the sensor type.
539 539  
540 540  [[image:image-20220624144904-12.png]]
541 541  
542 542  
543 -
544 544  (% style="color:#037691" %)**AT Command:**
545 545  
546 546  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:377px" %)
... ... @@ -549,12 +549,13 @@
549 549  
550 550  Eg: The setting command **AT+STYPE=802212** means:
551 551  
552 -|(% rowspan="2" %)Byte3|Bit23|Bit22|Bit21|Bit20|Bit19|Bit18|Bit17|Bit16
553 -|0|0|0|0|1|0|0|0
554 -|(% rowspan="2" %)Byte2|Bit15|Bit14|Bit13|Bit12|Bit11|Bit10|Bit9|Bit8
555 -|0|0|0|0|0|0|1|0
556 -|(% rowspan="2" %)Byte1|Bit7|Bit6|Bit5|Bit4|Bit3|Bit2|Bit1|Bit0
557 -|0|0|1|0|0|0|0|1
556 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:495px" %)
557 +|(% rowspan="2" style="width:57px" %)Byte3|(% style="width:57px" %)Bit23|(% style="width:59px" %)Bit22|(% style="width:56px" %)Bit21|(% style="width:51px" %)Bit20|(% style="width:54px" %)Bit19|(% style="width:54px" %)Bit18|(% style="width:52px" %)Bit17|(% style="width:52px" %)Bit16
558 +|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)0|(% style="width:51px" %)0|(% style="width:54px" %)1|(% style="width:54px" %)0|(% style="width:52px" %)0|(% style="width:52px" %)0
559 +|(% rowspan="2" style="width:57px" %)Byte2|(% style="width:57px" %)Bit15|(% style="width:59px" %)Bit14|(% style="width:56px" %)Bit13|(% style="width:51px" %)Bit12|(% style="width:54px" %)Bit11|(% style="width:54px" %)Bit10|(% style="width:52px" %)Bit9|(% style="width:52px" %)Bit8
560 +|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)0|(% style="width:51px" %)0|(% style="width:54px" %)0|(% style="width:54px" %)0|(% style="width:52px" %)1|(% style="width:52px" %)0
561 +|(% rowspan="2" style="width:57px" %)Byte1|(% style="width:57px" %)Bit7|(% style="width:59px" %)Bit6|(% style="width:56px" %)Bit5|(% style="width:51px" %)Bit4|(% style="width:54px" %)Bit3|(% style="width:54px" %)Bit2|(% style="width:52px" %)Bit1|(% style="width:52px" %)Bit0
562 +|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)1|(% style="width:51px" %)0|(% style="width:54px" %)0|(% style="width:54px" %)0|(% style="width:52px" %)0|(% style="width:52px" %)1
558 558  
559 559  So wsc1-L will upload the following data: Custom Sensor A1, Rain Gauge,CO2,BAT.
560 560  
... ... @@ -565,12 +565,11 @@
565 565  
566 566  (% style="color:red" %)**Note:**
567 567  
568 -~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned
573 +~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned.
569 569  
570 570  
571 571  
572 572  
573 -
574 574  = 4. Power consumption and battery =
575 575  
576 576  == 4.1 Total Power Consumption ==
... ... @@ -583,13 +583,15 @@
583 583  The main process unit WSC1-L is set to LoRaWAN Class C by default. If user want to reduce the power consumption of this unit, user can set it to run in Class A. In Class A mode, WSC1-L will not be to get real-time downlink command from IoT Server.
584 584  
585 585  
586 -
587 587  == 4.3 Battery ==
588 588  
589 -All sensors are only power by external power source. If external power source is off. All sensor won’t work.
592 +(((
593 +All sensors are only power by external power source. If external power source is off. All sensor won't work.
594 +)))
590 590  
591 -
596 +(((
592 592  Main Process Unit WSC1-L is powered by both external power source and internal 1000mAh rechargeable battery. If external power source is off, WSC1-L still runs and can send periodically uplinks, but the sensors value will become invalid.  External power source can recharge the 1000mAh rechargeable battery.
598 +)))
593 593  
594 594  
595 595  
... ... @@ -609,6 +609,8 @@
609 609  * IP Rating: IP65
610 610  * Support default sensors or 3rd party RS485 sensors
611 611  
618 +
619 +
612 612  == 5.2 Power Consumption ==
613 613  
614 614  WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA