Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Mengting Qiu on 2025/06/10 18:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -77,6 +77,7 @@ 77 77 * Mounting Kit includes pole and mast assembly. Each weather sensor has it’s own mounting assembly, user can check the sensor section in this manual. 78 78 * Cabinet. 79 79 80 + 80 80 == 2.2 How it works? == 81 81 82 82 ((( ... ... @@ -94,6 +94,7 @@ 94 94 1. WSC1-L will auto scan available weather sensors when power on or reboot. 95 95 1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors. 96 96 98 + 97 97 == 2.3 Example to use for LoRaWAN network == 98 98 99 99 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. ... ... @@ -150,6 +150,10 @@ 150 150 * Valid Sensor Value: Use FPORT=2 151 151 * Other control command: Use FPORT other than 2. 152 152 155 + 156 + 157 + 158 + 153 153 === 2.4.1 Uplink FPORT~=5, Device Status === 154 154 155 155 Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours ... ... @@ -374,6 +374,7 @@ 374 374 These commands only valid for WSC1-L, as below: 375 375 376 376 383 + 377 377 == 3.1 Set Transmit Interval Time == 378 378 379 379 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -451,7 +451,6 @@ 451 451 * has_CRC: 1 452 452 * timeout: 1500 (Fill in the test according to the actual situation) 453 453 454 - 455 455 **So the input command is:** 456 456 457 457 AT+DYSENSOR=A1,8,A103000000019CAA,8,24,1,1500 ... ... @@ -519,7 +519,6 @@ 519 519 Range : 0~~10000 520 520 )))|(% style="width:85px" %)OK 521 521 522 - 523 523 (% style="color:#037691" %)**Downlink Command:** 524 524 525 525 Format: Command Code (0xE0) followed by 3 bytes time value. ... ... @@ -535,25 +535,26 @@ 535 535 536 536 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values. 537 537 538 -See [[definition>>||anchor="H"]] for the sensor type. 543 +See [[definition>>||anchor="HWeatherSensorTypes:"]] for the sensor type. 539 539 540 540 [[image:image-20220624144904-12.png]] 541 541 542 542 543 - 544 544 (% style="color:#037691" %)**AT Command:** 545 545 546 -|**Command Example**|**Function**|**Response** 547 -|AT+STYPE=80221|Set sensor types|OK 550 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:377px" %) 551 +|=(% style="width: 157px;" %)**Command Example**|=(% style="width: 130px;" %)**Function**|=(% style="width: 87px;" %)**Response** 552 +|(% style="width:157px" %)AT+STYPE=80221|(% style="width:130px" %)Set sensor types|(% style="width:87px" %)OK 548 548 549 549 Eg: The setting command **AT+STYPE=802212** means: 550 550 551 -|(% rowspan="2" %)Byte3|Bit23|Bit22|Bit21|Bit20|Bit19|Bit18|Bit17|Bit16 552 -|0|0|0|0|1|0|0|0 553 -|(% rowspan="2" %)Byte2|Bit15|Bit14|Bit13|Bit12|Bit11|Bit10|Bit9|Bit8 554 -|0|0|0|0|0|0|1|0 555 -|(% rowspan="2" %)Byte1|Bit7|Bit6|Bit5|Bit4|Bit3|Bit2|Bit1|Bit0 556 -|0|0|1|0|0|0|0|1 556 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:495px" %) 557 +|(% rowspan="2" style="width:57px" %)Byte3|(% style="width:57px" %)Bit23|(% style="width:59px" %)Bit22|(% style="width:56px" %)Bit21|(% style="width:51px" %)Bit20|(% style="width:54px" %)Bit19|(% style="width:54px" %)Bit18|(% style="width:52px" %)Bit17|(% style="width:52px" %)Bit16 558 +|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)0|(% style="width:51px" %)0|(% style="width:54px" %)1|(% style="width:54px" %)0|(% style="width:52px" %)0|(% style="width:52px" %)0 559 +|(% rowspan="2" style="width:57px" %)Byte2|(% style="width:57px" %)Bit15|(% style="width:59px" %)Bit14|(% style="width:56px" %)Bit13|(% style="width:51px" %)Bit12|(% style="width:54px" %)Bit11|(% style="width:54px" %)Bit10|(% style="width:52px" %)Bit9|(% style="width:52px" %)Bit8 560 +|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)0|(% style="width:51px" %)0|(% style="width:54px" %)0|(% style="width:54px" %)0|(% style="width:52px" %)1|(% style="width:52px" %)0 561 +|(% rowspan="2" style="width:57px" %)Byte1|(% style="width:57px" %)Bit7|(% style="width:59px" %)Bit6|(% style="width:56px" %)Bit5|(% style="width:51px" %)Bit4|(% style="width:54px" %)Bit3|(% style="width:54px" %)Bit2|(% style="width:52px" %)Bit1|(% style="width:52px" %)Bit0 562 +|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)1|(% style="width:51px" %)0|(% style="width:54px" %)0|(% style="width:54px" %)0|(% style="width:52px" %)0|(% style="width:52px" %)1 557 557 558 558 So wsc1-L will upload the following data: Custom Sensor A1, Rain Gauge,CO2,BAT. 559 559 ... ... @@ -564,12 +564,11 @@ 564 564 565 565 (% style="color:red" %)**Note:** 566 566 567 -~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned 573 +~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned. 568 568 569 569 570 570 571 571 572 - 573 573 = 4. Power consumption and battery = 574 574 575 575 == 4.1 Total Power Consumption == ... ... @@ -582,13 +582,15 @@ 582 582 The main process unit WSC1-L is set to LoRaWAN Class C by default. If user want to reduce the power consumption of this unit, user can set it to run in Class A. In Class A mode, WSC1-L will not be to get real-time downlink command from IoT Server. 583 583 584 584 585 - 586 586 == 4.3 Battery == 587 587 588 -All sensors are only power by external power source. If external power source is off. All sensor won’t work. 592 +((( 593 +All sensors are only power by external power source. If external power source is off. All sensor won't work. 594 +))) 589 589 590 - 596 +((( 591 591 Main Process Unit WSC1-L is powered by both external power source and internal 1000mAh rechargeable battery. If external power source is off, WSC1-L still runs and can send periodically uplinks, but the sensors value will become invalid. External power source can recharge the 1000mAh rechargeable battery. 598 +))) 592 592 593 593 594 594 ... ... @@ -608,6 +608,8 @@ 608 608 * IP Rating: IP65 609 609 * Support default sensors or 3rd party RS485 sensors 610 610 618 + 619 + 611 611 == 5.2 Power Consumption == 612 612 613 613 WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA