Last modified by Mengting Qiu on 2025/06/10 18:53

From version 32.2
edited by Xiaoling
on 2022/06/24 14:49
Change comment: There is no comment for this version
To version 32.11
edited by Xiaoling
on 2022/06/24 14:59
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -77,6 +77,8 @@
77 77  * Mounting Kit includes pole and mast assembly. Each weather sensor has it’s own mounting assembly, user can check the sensor section in this manual.
78 78  * Cabinet.
79 79  
80 +
81 +
80 80  == 2.2 How it works? ==
81 81  
82 82  (((
... ... @@ -94,6 +94,8 @@
94 94  1. WSC1-L will auto scan available weather sensors when power on or reboot.
95 95  1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors.
96 96  
99 +
100 +
97 97  == 2.3 Example to use for LoRaWAN network ==
98 98  
99 99  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -150,6 +150,7 @@
150 150  * Valid Sensor Value: Use FPORT=2
151 151  * Other control command: Use FPORT other than 2.
152 152  
157 +
153 153  === 2.4.1 Uplink FPORT~=5, Device Status ===
154 154  
155 155  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -374,6 +374,7 @@
374 374  These commands only valid for WSC1-L, as below:
375 375  
376 376  
382 +
377 377  == 3.1 Set Transmit Interval Time ==
378 378  
379 379  Feature: Change LoRaWAN End Node Transmit Interval.
... ... @@ -394,6 +394,7 @@
394 394  
395 395  
396 396  
403 +
397 397  == 3.2 Set Emergency Mode ==
398 398  
399 399  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
... ... @@ -410,6 +410,7 @@
410 410  
411 411  
412 412  
420 +
413 413  == 3.3 Add or Delete RS485 Sensor ==
414 414  
415 415  Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors.
... ... @@ -427,6 +427,7 @@
427 427  * timeout:  RS485 receive timeout (uint:ms). Device will close receive window after timeout
428 428  
429 429  
438 +
430 430  **Example:**
431 431  
432 432  User need to change external sensor use the type code as address code.
... ... @@ -482,6 +482,7 @@
482 482  
483 483  
484 484  
494 +
485 485  == 3.4 RS485 Test Command ==
486 486  
487 487  (% style="color:#037691" %)**AT Command:**
... ... @@ -505,6 +505,7 @@
505 505  
506 506  
507 507  
518 +
508 508  == 3.5 RS485 response timeout ==
509 509  
510 510  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -531,29 +531,31 @@
531 531  
532 532  
533 533  
545 +
534 534  == 3.6 Set Sensor Type ==
535 535  
536 536  Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.
537 537  
538 -See [[definition>>||anchor="H"]] for the sensor type.
550 +See [[definition>>||anchor="HWeatherSensorTypes:"]] for the sensor type.
539 539  
540 540  [[image:image-20220624144904-12.png]]
541 541  
542 542  
543 -
544 544  (% style="color:#037691" %)**AT Command:**
545 545  
546 -|**Command Example**|**Function**|**Response**
547 -|AT+STYPE=80221|Set sensor types|OK
557 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:377px" %)
558 +|=(% style="width: 157px;" %)**Command Example**|=(% style="width: 130px;" %)**Function**|=(% style="width: 87px;" %)**Response**
559 +|(% style="width:157px" %)AT+STYPE=80221|(% style="width:130px" %)Set sensor types|(% style="width:87px" %)OK
548 548  
549 549  Eg: The setting command **AT+STYPE=802212** means:
550 550  
551 -|(% rowspan="2" %)Byte3|Bit23|Bit22|Bit21|Bit20|Bit19|Bit18|Bit17|Bit16
552 -|0|0|0|0|1|0|0|0
553 -|(% rowspan="2" %)Byte2|Bit15|Bit14|Bit13|Bit12|Bit11|Bit10|Bit9|Bit8
554 -|0|0|0|0|0|0|1|0
555 -|(% rowspan="2" %)Byte1|Bit7|Bit6|Bit5|Bit4|Bit3|Bit2|Bit1|Bit0
556 -|0|0|1|0|0|0|0|1
563 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:495px" %)
564 +|(% rowspan="2" style="width:57px" %)Byte3|(% style="width:57px" %)Bit23|(% style="width:59px" %)Bit22|(% style="width:56px" %)Bit21|(% style="width:51px" %)Bit20|(% style="width:54px" %)Bit19|(% style="width:54px" %)Bit18|(% style="width:52px" %)Bit17|(% style="width:52px" %)Bit16
565 +|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)0|(% style="width:51px" %)0|(% style="width:54px" %)1|(% style="width:54px" %)0|(% style="width:52px" %)0|(% style="width:52px" %)0
566 +|(% rowspan="2" style="width:57px" %)Byte2|(% style="width:57px" %)Bit15|(% style="width:59px" %)Bit14|(% style="width:56px" %)Bit13|(% style="width:51px" %)Bit12|(% style="width:54px" %)Bit11|(% style="width:54px" %)Bit10|(% style="width:52px" %)Bit9|(% style="width:52px" %)Bit8
567 +|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)0|(% style="width:51px" %)0|(% style="width:54px" %)0|(% style="width:54px" %)0|(% style="width:52px" %)1|(% style="width:52px" %)0
568 +|(% rowspan="2" style="width:57px" %)Byte1|(% style="width:57px" %)Bit7|(% style="width:59px" %)Bit6|(% style="width:56px" %)Bit5|(% style="width:51px" %)Bit4|(% style="width:54px" %)Bit3|(% style="width:54px" %)Bit2|(% style="width:52px" %)Bit1|(% style="width:52px" %)Bit0
569 +|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)1|(% style="width:51px" %)0|(% style="width:54px" %)0|(% style="width:54px" %)0|(% style="width:52px" %)0|(% style="width:52px" %)1
557 557  
558 558  So wsc1-L will upload the following data: Custom Sensor A1, Rain Gauge,CO2,BAT.
559 559  
... ... @@ -564,12 +564,11 @@
564 564  
565 565  (% style="color:red" %)**Note:**
566 566  
567 -~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned
580 +~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned.
568 568  
569 569  
570 570  
571 571  
572 -
573 573  = 4. Power consumption and battery =
574 574  
575 575  == 4.1 Total Power Consumption ==
... ... @@ -582,13 +582,15 @@
582 582  The main process unit WSC1-L is set to LoRaWAN Class C by default. If user want to reduce the power consumption of this unit, user can set it to run in Class A. In Class A mode, WSC1-L will not be to get real-time downlink command from IoT Server.
583 583  
584 584  
585 -
586 586  == 4.3 Battery ==
587 587  
588 -All sensors are only power by external power source. If external power source is off. All sensor won’t work.
599 +(((
600 +All sensors are only power by external power source. If external power source is off. All sensor won't work.
601 +)))
589 589  
590 -
603 +(((
591 591  Main Process Unit WSC1-L is powered by both external power source and internal 1000mAh rechargeable battery. If external power source is off, WSC1-L still runs and can send periodically uplinks, but the sensors value will become invalid.  External power source can recharge the 1000mAh rechargeable battery.
605 +)))
592 592  
593 593  
594 594  
... ... @@ -608,6 +608,9 @@
608 608  * IP Rating: IP65
609 609  * Support default sensors or 3rd party RS485 sensors
610 610  
625 +
626 +
627 +
611 611  == 5.2 Power Consumption ==
612 612  