Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/04/25 09:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -77,6 +77,9 @@ 77 77 * Mounting Kit includes pole and mast assembly. Each weather sensor has it’s own mounting assembly, user can check the sensor section in this manual. 78 78 * Cabinet. 79 79 80 + 81 + 82 + 80 80 == 2.2 How it works? == 81 81 82 82 ((( ... ... @@ -94,6 +94,9 @@ 94 94 1. WSC1-L will auto scan available weather sensors when power on or reboot. 95 95 1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors. 96 96 100 + 101 + 102 + 97 97 == 2.3 Example to use for LoRaWAN network == 98 98 99 99 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. ... ... @@ -152,7 +152,6 @@ 152 152 153 153 154 154 155 - 156 156 === 2.4.1 Uplink FPORT~=5, Device Status === 157 157 158 158 Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours ... ... @@ -377,6 +377,7 @@ 377 377 These commands only valid for WSC1-L, as below: 378 378 379 379 385 + 380 380 == 3.1 Set Transmit Interval Time == 381 381 382 382 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -396,6 +396,9 @@ 396 396 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 397 397 398 398 405 + 406 + 407 + 399 399 == 3.2 Set Emergency Mode == 400 400 401 401 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. ... ... @@ -411,6 +411,9 @@ 411 411 * 0xE100 Same as: AT+ALARMMOD=0 412 412 413 413 423 + 424 + 425 + 414 414 == 3.3 Add or Delete RS485 Sensor == 415 415 416 416 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. ... ... @@ -480,6 +480,9 @@ 480 480 * 0xE5FF 481 481 482 482 495 + 496 + 497 + 483 483 == 3.4 RS485 Test Command == 484 484 485 485 (% style="color:#037691" %)**AT Command:** ... ... @@ -502,6 +502,9 @@ 502 502 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 503 503 504 504 520 + 521 + 522 + 505 505 == 3.5 RS485 response timeout == 506 506 507 507 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -526,6 +526,9 @@ 526 526 * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds 527 527 528 528 547 + 548 + 549 + 529 529 == 3.6 Set Sensor Type == 530 530 531 531 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values. ... ... @@ -535,6 +535,7 @@ 535 535 [[image:image-20220624144904-12.png]] 536 536 537 537 559 + 538 538 (% style="color:#037691" %)**AT Command:** 539 539 540 540 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:377px" %) ... ... @@ -606,6 +606,9 @@ 606 606 * Support default sensors or 3rd party RS485 sensors 607 607 608 608 631 + 632 + 633 + 609 609 == 5.2 Power Consumption == 610 610 611 611 WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA