Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/04/25 09:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -77,7 +77,6 @@ 77 77 * Mounting Kit includes pole and mast assembly. Each weather sensor has it’s own mounting assembly, user can check the sensor section in this manual. 78 78 * Cabinet. 79 79 80 - 81 81 == 2.2 How it works? == 82 82 83 83 ((( ... ... @@ -95,7 +95,6 @@ 95 95 1. WSC1-L will auto scan available weather sensors when power on or reboot. 96 96 1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors. 97 97 98 - 99 99 == 2.3 Example to use for LoRaWAN network == 100 100 101 101 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. ... ... @@ -155,7 +155,6 @@ 155 155 156 156 157 157 158 - 159 159 === 2.4.1 Uplink FPORT~=5, Device Status === 160 160 161 161 Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours ... ... @@ -380,7 +380,6 @@ 380 380 These commands only valid for WSC1-L, as below: 381 381 382 382 383 - 384 384 == 3.1 Set Transmit Interval Time == 385 385 386 386 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -400,7 +400,6 @@ 400 400 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 401 401 402 402 403 - 404 404 == 3.2 Set Emergency Mode == 405 405 406 406 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. ... ... @@ -416,7 +416,6 @@ 416 416 * 0xE100 Same as: AT+ALARMMOD=0 417 417 418 418 419 - 420 420 == 3.3 Add or Delete RS485 Sensor == 421 421 422 422 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. ... ... @@ -433,7 +433,6 @@ 433 433 * has_CRC: RS485 Response crc check (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0. 434 434 * timeout: RS485 receive timeout (uint:ms). Device will close receive window after timeout 435 435 436 - 437 437 **Example:** 438 438 439 439 User need to change external sensor use the type code as address code. ... ... @@ -487,7 +487,6 @@ 487 487 * 0xE5FF 488 488 489 489 490 - 491 491 == 3.4 RS485 Test Command == 492 492 493 493 (% style="color:#037691" %)**AT Command:** ... ... @@ -510,7 +510,6 @@ 510 510 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 511 511 512 512 513 - 514 514 == 3.5 RS485 response timeout == 515 515 516 516 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -535,7 +535,6 @@ 535 535 * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds 536 536 537 537 538 - 539 539 == 3.6 Set Sensor Type == 540 540 541 541 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values. ... ... @@ -598,7 +598,6 @@ 598 598 ))) 599 599 600 600 601 - 602 602 = 5. Main Process Unit WSC1-L = 603 603 604 604 == 5.1 Features == ... ... @@ -616,13 +616,11 @@ 616 616 * Support default sensors or 3rd party RS485 sensors 617 617 618 618 619 - 620 620 == 5.2 Power Consumption == 621 621 622 622 WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA 623 623 624 624 625 - 626 626 == 5.3 Storage & Operation Temperature == 627 627 628 628 -20°C to +60°C ... ... @@ -630,7 +630,7 @@ 630 630 631 631 == 5.4 Pin Mapping == 632 632 633 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image004.png]]620 +[[image:1656054149793-239.png]] 634 634 635 635 636 636 == 5.5 Mechanical == ... ... @@ -638,14 +638,12 @@ 638 638 Refer LSn50v2 enclosure drawing in: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/>>url:https://www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/]] 639 639 640 640 641 - 642 - 643 643 == 5.6 Connect to RS485 Sensors == 644 644 645 645 WSC1-L includes a RS485 converter PCB. Which help it easy to connect multiply RS485 sensors. Below is the photo for reference. 646 646 647 647 648 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image018.png]]633 +[[image:1656054389031-379.png]] 649 649 650 650 651 651 Hardware Design for the Converter Board please see: ... ... @@ -653,37 +653,22 @@ 653 653 [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Weather_Station/RS485_Converter_Board/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Weather_Station/RS485_Converter_Board/]] 654 654 655 655 656 - 657 - 658 - 659 659 = 6. Weather Sensors = 660 660 661 661 == 6.1 Rain Gauge ~-~- WSS-01 == 662 662 645 + 663 663 WSS-01 RS485 Rain Gauge is used in meteorology and hydrology to gather and measure the amount of liquid precipitation (mainly rainfall) over an area. 664 664 648 +WSS-01 uses a tipping bucket to detect rainfall. The tipping bucket use 3D streamline shape to make sure it works smoothly and is easy to clean. 665 665 666 -WSS-01 usesatippingbucket todetectrainfall. The tippingbucket use3Dstreamline650 +WSS-01 is designed to support the Dragino Weather station solution. Users only need to connect WSS-01 RS485 interface to WSC1-L. The weather station main processor WSC1-L can detect and upload the rainfall to the IoT Server via wireless LoRaWAN protocol 667 667 668 - shape tomake sureitworkssmoothlyandiseasy to clean.652 +The tipping bucket of WSS-01 is adjusted to the best angle. When installation, user only needs to screw up and adjust the bottom horizontally. 669 669 670 - 671 -WSS-01 is designed to support the Dragino Weather station solution. 672 - 673 -Users only need to connect WSS-01 RS485 interface to WSC1-L. The weather station main 674 - 675 -processor WSC1-L can detect and upload the rainfall to the IoT Server via wireless LoRaWAN protocol 676 - 677 - 678 -The tipping bucket of WSS-01 is adjusted to the best angle. When installation, user only needs 679 - 680 -to screw up and adjust the bottom horizontally. 681 - 682 - 683 683 WSS-01 package includes screw which can be installed to ground. If user want to install WSS-01 on pole, they can purchase WS-K2 bracket kit. 684 684 685 685 686 - 687 687 === 6.1.1 Feature === 688 688 689 689 * RS485 Rain Gauge ... ... @@ -692,6 +692,10 @@ 692 692 * ABS enclosure. 693 693 * Horizontal adjustable. 694 694 665 + 666 + 667 + 668 + 695 695 === 6.1.2 Specification === 696 696 697 697 * Resolution: 0.2mm ... ... @@ -703,6 +703,10 @@ 703 703 * Working Humidity: <100% (no dewing) 704 704 * Power Consumption: 4mA @ 12v. 705 705 680 + 681 + 682 + 683 + 706 706 === 6.1.3 Dimension === 707 707 708 708 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image019.jpg||alt="c2d3aee592ccc873bea6dd891451df2"]] ... ... @@ -764,6 +764,10 @@ 764 764 * RS485 wind speed / direction sensor 765 765 * PC enclosure, resist corrosion 766 766 745 + 746 + 747 + 748 + 767 767 === 6.2.2 Specification === 768 768 769 769 * Wind speed range: 0 ~~ 30m/s, (always show 30m/s for higher speed) ... ... @@ -777,6 +777,10 @@ 777 777 * Power Consumption: 13mA ~~ 12v. 778 778 * Cable Length: 2 meters 779 779 762 + 763 + 764 + 765 + 780 780 === 6.2.3 Dimension === 781 781 782 782 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.jpg]][[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.jpg]] ... ... @@ -834,6 +834,10 @@ 834 834 * NDIR to measure CO2 with Internal Temperature Compensation 835 835 * Laser Beam Scattering to PM2.5 and PM10 836 836 823 + 824 + 825 + 826 + 837 837 === 6.3.2 Specification === 838 838 839 839 * CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃) ... ... @@ -851,6 +851,10 @@ 851 851 ** CO2: 0~95%RH 852 852 * Power Consumption: 50mA@ 12v. 853 853 844 + 845 + 846 + 847 + 854 854 === 6.3.3 Dimension === 855 855 856 856 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]] ... ... @@ -896,6 +896,10 @@ 896 896 * Surface heating to dry 897 897 * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion 898 898 893 + 894 + 895 + 896 + 899 899 === 6.4.2 Specification === 900 900 901 901 * Detect if there is rain or snow ... ... @@ -907,6 +907,10 @@ 907 907 ** No heating: 12mA @ 12v, 908 908 ** heating: 94ma @ 12v. 909 909 908 + 909 + 910 + 911 + 910 910 === 6.4.3 Dimension === 911 911 912 912 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image031.png]] ... ... @@ -956,6 +956,10 @@ 956 956 957 957 * RS485 Temperature, Humidity, Illuminance, Pressure sensor 958 958 961 + 962 + 963 + 964 + 959 959 === 6.5.2 Specification === 960 960 961 961 * Input Power: DC 12 ~~ 24v ... ... @@ -980,6 +980,10 @@ 980 980 * Working Humidity: 10~90%RH 981 981 * Power Consumption: 4mA @ 12v 982 982 989 + 990 + 991 + 992 + 983 983 === 6.5.3 Dimension === 984 984 985 985 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image034.jpg]] ... ... @@ -1025,6 +1025,10 @@ 1025 1025 * Measure Total Radiation between 0.3~3μm(300~3000nm) 1026 1026 * Measure Reflected Radiation if sense area towards ground. 1027 1027 1038 + 1039 + 1040 + 1041 + 1028 1028 === 6.6.2 Specification === 1029 1029 1030 1030 * Input Power: DC 5 ~~ 24v ... ... @@ -1040,6 +1040,10 @@ 1040 1040 * Working Humidity: 10~90%RH 1041 1041 * Power Consumption: 4mA @ 12v 1042 1042 1057 + 1058 + 1059 + 1060 + 1043 1043 === 6.6.3 Dimension === 1044 1044 1045 1045 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] ... ... @@ -1097,6 +1097,10 @@ 1097 1097 * Working Humidity: 10~90%RH 1098 1098 * Power Consumption: 3mA @ 12v 1099 1099 1118 + 1119 + 1120 + 1121 + 1100 1100 === 6.7.3 Dimension === 1101 1101 1102 1102 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] ... ... @@ -1166,19 +1166,23 @@ 1166 1166 1167 1167 == 9.1 Main Process Unit == 1168 1168 1169 -Part Number: **WSC1-L-XX** 1191 +Part Number: **(% style="color:blue" %)WSC1-L-XX** 1170 1170 1171 -**XX**: The default frequency band 1193 +**(% style="color:blue" %)XX**(%%): The default frequency band 1172 1172 1173 -* **AS923**: LoRaWAN AS923 band 1174 -* **AU915**: LoRaWAN AU915 band 1175 -* **EU433**: LoRaWAN EU433 band 1176 -* **EU868**: LoRaWAN EU868 band 1177 -* **KR920**: LoRaWAN KR920 band 1178 -* **US915**: LoRaWAN US915 band 1179 -* **IN865**: LoRaWAN IN865 band 1180 -* **CN470**: LoRaWAN CN470 band 1195 +* **(% style="color:red" %)AS923**(%%): LoRaWAN AS923 band 1196 +* **(% style="color:red" %)AU915**(%%): LoRaWAN AU915 band 1197 +* **(% style="color:red" %)EU433**(%%): LoRaWAN EU433 band 1198 +* **(% style="color:red" %)EU868**(%%): LoRaWAN EU868 band 1199 +* **(% style="color:red" %)KR920**(%%): LoRaWAN KR920 band 1200 +* **(% style="color:red" %)US915**(%%): LoRaWAN US915 band 1201 +* **(% style="color:red" %)IN865**(%%): LoRaWAN IN865 band 1202 +* **(% style="color:red" %)CN470**(%%): LoRaWAN CN470 band 1181 1181 1204 + 1205 + 1206 + 1207 + 1182 1182 == 9.2 Sensors == 1183 1183 1184 1184 |**Sensor Model**|**Part Number** ... ... @@ -1191,6 +1191,8 @@ 1191 1191 |**Total Solar Radiation Sensor**|WSS-06 1192 1192 |**PAR (Photosynthetically Available Radiation)**|WSS-07 1193 1193 1220 + 1221 + 1194 1194 = 10. Support = 1195 1195 1196 1196 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
- 1656054149793-239.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +492.6 KB - Content
- 1656054389031-379.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content