... ... @@ -78,6 +78,9 @@
78 78  * Cabinet.
79 79  
80 80  
81 +
82 +
83 +
81 81  == 2.2 How it works? ==
82 82  
83 83  (((
... ... @@ -96,6 +96,9 @@
96 96  1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors.
97 97  
98 98  
102 +
103 +
104 +
99 99  == 2.3 Example to use for LoRaWAN network ==
100 100  
101 101  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -155,7 +155,6 @@
155 155  
156 156  
157 157  
158 -
159 159  === 2.4.1 Uplink FPORT~=5, Device Status ===
160 160  
161 161  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -380,7 +380,6 @@
380 380  These commands only valid for WSC1-L, as below:
381 381  
382 382  
383 -
384 384  == 3.1 Set Transmit Interval Time ==
385 385  
386 386  Feature: Change LoRaWAN End Node Transmit Interval.
... ... @@ -458,6 +458,7 @@
458 458  * has_CRC: 1
459 459  * timeout: 1500 (Fill in the test according to the actual situation)
460 460  
465 +
461 461  **So the input command is:**
462 462  
463 463  AT+DYSENSOR=A1,8,A103000000019CAA,8,24,1,1500
... ... @@ -525,6 +525,7 @@
525 525  Range : 0~~10000
526 526  )))|(% style="width:85px" %)OK
527 527  
533 +
528 528  (% style="color:#037691" %)**Downlink Command:**
529 529  
530 530  Format: Command Code (0xE0) followed by 3 bytes time value.
... ... @@ -540,11 +540,12 @@
540 540  
541 541  Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.
542 542  
543 -See [[definition>>||anchor="HWeatherSensorTypes:"]] for the sensor type.
549 +See [[definition>>||anchor="H"]] for the sensor type.
544 544  
545 545  [[image:image-20220624144904-12.png]]
546 546  
547 547  
554 +
548 548  (% style="color:#037691" %)**AT Command:**
549 549  
550 550  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:377px" %)
... ... @@ -551,6 +551,7 @@
551 551  |=(% style="width: 157px;" %)**Command Example**|=(% style="width: 130px;" %)**Function**|=(% style="width: 87px;" %)**Response**
552 552  |(% style="width:157px" %)AT+STYPE=80221|(% style="width:130px" %)Set sensor types|(% style="width:87px" %)OK
553 553  
561 +
554 554  Eg: The setting command **AT+STYPE=802212** means:
555 555  
556 556  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:495px" %)
... ... @@ -587,15 +587,13 @@
587 587  The main process unit WSC1-L is set to LoRaWAN Class C by default. If user want to reduce the power consumption of this unit, user can set it to run in Class A. In Class A mode, WSC1-L will not be to get real-time downlink command from IoT Server.
588 588  
589 589  
598 +
590 590  == 4.3 Battery ==
591 591  
592 -(((
593 -All sensors are only power by external power source. If external power source is off. All sensor won't work.
594 -)))
601 +All sensors are only power by external power source. If external power source is off. All sensor won’t work.
595 595  
596 -(((
603 +
597 597  Main Process Unit WSC1-L is powered by both external power source and internal 1000mAh rechargeable battery. If external power source is off, WSC1-L still runs and can send periodically uplinks, but the sensors value will become invalid.  External power source can recharge the 1000mAh rechargeable battery.
598 -)))
599 599  
600 600  
601 601  
... ... @@ -615,8 +615,6 @@
615 615  * IP Rating: IP65
616 616  * Support default sensors or 3rd party RS485 sensors
617 617  
618 -
619 -
620 620  == 5.2 Power Consumption ==
621 621  
622 622  WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA