Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/04/25 09:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -77,7 +77,6 @@ 77 77 * Mounting Kit includes pole and mast assembly. Each weather sensor has it’s own mounting assembly, user can check the sensor section in this manual. 78 78 * Cabinet. 79 79 80 - 81 81 == 2.2 How it works? == 82 82 83 83 ((( ... ... @@ -95,7 +95,6 @@ 95 95 1. WSC1-L will auto scan available weather sensors when power on or reboot. 96 96 1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors. 97 97 98 - 99 99 == 2.3 Example to use for LoRaWAN network == 100 100 101 101 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. ... ... @@ -155,7 +155,6 @@ 155 155 156 156 157 157 158 - 159 159 === 2.4.1 Uplink FPORT~=5, Device Status === 160 160 161 161 Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours ... ... @@ -380,7 +380,6 @@ 380 380 These commands only valid for WSC1-L, as below: 381 381 382 382 383 - 384 384 == 3.1 Set Transmit Interval Time == 385 385 386 386 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -400,7 +400,6 @@ 400 400 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 401 401 402 402 403 - 404 404 == 3.2 Set Emergency Mode == 405 405 406 406 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. ... ... @@ -416,7 +416,6 @@ 416 416 * 0xE100 Same as: AT+ALARMMOD=0 417 417 418 418 419 - 420 420 == 3.3 Add or Delete RS485 Sensor == 421 421 422 422 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. ... ... @@ -433,7 +433,6 @@ 433 433 * has_CRC: RS485 Response crc check (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0. 434 434 * timeout: RS485 receive timeout (uint:ms). Device will close receive window after timeout 435 435 436 - 437 437 **Example:** 438 438 439 439 User need to change external sensor use the type code as address code. ... ... @@ -487,7 +487,6 @@ 487 487 * 0xE5FF 488 488 489 489 490 - 491 491 == 3.4 RS485 Test Command == 492 492 493 493 (% style="color:#037691" %)**AT Command:** ... ... @@ -510,7 +510,6 @@ 510 510 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 511 511 512 512 513 - 514 514 == 3.5 RS485 response timeout == 515 515 516 516 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -535,7 +535,6 @@ 535 535 * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds 536 536 537 537 538 - 539 539 == 3.6 Set Sensor Type == 540 540 541 541 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values. ... ... @@ -598,7 +598,6 @@ 598 598 ))) 599 599 600 600 601 - 602 602 = 5. Main Process Unit WSC1-L = 603 603 604 604 == 5.1 Features == ... ... @@ -616,7 +616,6 @@ 616 616 * Support default sensors or 3rd party RS485 sensors 617 617 618 618 619 - 620 620 == 5.2 Power Consumption == 621 621 622 622 WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA