<
From version < 32.12 >
edited by Xiaoling
on 2022/06/24 15:00
To version < 31.4 >
edited by Xiaoling
on 2022/06/24 14:41
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -77,7 +77,6 @@
77 77  * Mounting Kit includes pole and mast assembly. Each weather sensor has it’s own mounting assembly, user can check the sensor section in this manual.
78 78  * Cabinet.
79 79  
80 -
81 81  == 2.2 How it works? ==
82 82  
83 83  (((
... ... @@ -95,7 +95,6 @@
95 95  1. WSC1-L will auto scan available weather sensors when power on or reboot.
96 96  1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors.
97 97  
98 -
99 99  == 2.3 Example to use for LoRaWAN network ==
100 100  
101 101  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -152,10 +152,6 @@
152 152  * Valid Sensor Value: Use FPORT=2
153 153  * Other control command: Use FPORT other than 2.
154 154  
155 -
156 -
157 -
158 -
159 159  === 2.4.1 Uplink FPORT~=5, Device Status ===
160 160  
161 161  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -380,7 +380,6 @@
380 380  These commands only valid for WSC1-L, as below:
381 381  
382 382  
383 -
384 384  == 3.1 Set Transmit Interval Time ==
385 385  
386 386  Feature: Change LoRaWAN End Node Transmit Interval.
... ... @@ -448,7 +448,7 @@
448 448  [[image:image-20220624143618-11.png]]
449 449  
450 450  
451 -**Then the following parameters should be:**
444 +Then the following parameters should be:
452 452  
453 453  * Address_Code range: A1
454 454  * Query_Length: 8
... ... @@ -458,7 +458,7 @@
458 458  * has_CRC: 1
459 459  * timeout: 1500 (Fill in the test according to the actual situation)
460 460  
461 -**So the input command is:**
454 +So the input command is:
462 462  
463 463  AT+DYSENSOR=A1,8,A103000000019CAA,8,24,1,1500
464 464  
... ... @@ -465,15 +465,14 @@
465 465  
466 466  In every sampling. WSC1-L will auto append the sensor segment as per this structure and uplink.
467 467  
468 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:351px" %)
469 -|=(% style="width: 94px;" %)Type Code|=(% style="width: 121px;" %)Length (Bytes)|=(% style="width: 132px;" %)Measured Value
470 -|(% style="width:94px" %)A1|(% style="width:121px" %)2|(% style="width:132px" %)0x000A
461 +|Type Code|Length (Bytes)|Measured Value
462 +|A1|2|0x000A
471 471  
472 -**Related commands:**
464 +Related commands:
473 473  
474 -AT+DYSENSOR=A1,0  ~-~->  Delete 3^^rd^^ party sensor A1.
466 +AT+DYSENSOR=A1,0 > Delete 3^^rd^^ party sensor A1.
475 475  
476 -AT+DYSENSOR  ~-~->  List All 3^^rd^^ Party Sensor. Like below:
468 +AT+DYSENSOR ~-~-> List All 3^^rd^^ Party Sensor. Like below:
477 477  
478 478  
479 479  (% style="color:#037691" %)**Downlink Command:  **
... ... @@ -492,13 +492,12 @@
492 492  
493 493  (% style="color:#037691" %)**AT Command:**
494 494  
495 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:474px" %)
496 -|=(% style="width: 159px;" %)**Command Example**|=(% style="width: 227px;" %)**Function**|=(% style="width: 85px;" %)**Response**
497 -|(% style="width:159px" %)AT+RSWRITE=xxxxxx|(% style="width:227px" %)(((
487 +|**Command Example**|**Function**|**Response**
488 +|AT+RSWRITE=xxxxxx|(((
498 498  Send command to 485 sensor
499 499  
500 500  Range : no more than 10 bytes
501 -)))|(% style="width:85px" %)OK
492 +)))|OK
502 502  
503 503  Eg: Send command **01 03 00 00 00 01 84 0A** to 485 sensor
504 504  
... ... @@ -517,13 +517,12 @@
517 517  
518 518  (% style="color:#037691" %)**AT Command:**
519 519  
520 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:433px" %)
521 -|=(% style="width: 157px;" %)**Command Example**|=(% style="width: 188px;" %)**Function**|=(% style="width: 85px;" %)**Response**
522 -|(% style="width:157px" %)AT+DTR=1000|(% style="width:188px" %)(((
511 +|**Command Example**|**Function**|**Response**
512 +|AT+DTR=1000|(((
523 523  Set response timeout to:
524 524  
525 525  Range : 0~~10000
526 -)))|(% style="width:85px" %)OK
516 +)))|OK
527 527  
528 528  (% style="color:#037691" %)**Downlink Command:**
529 529  
... ... @@ -540,26 +540,45 @@
540 540  
541 541  Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.
542 542  
543 -See [[definition>>||anchor="HWeatherSensorTypes:"]] for the sensor type.
533 +See [[definition>>||anchor="H"]] for the sensor type.
544 544  
545 -[[image:image-20220624144904-12.png]]
546 546  
536 +|(% rowspan="2" %)Byte3|Bit23|Bit22|Bit21|Bit20|Bit19|Bit18|Bit17|Bit16
537 +| |A4|A3|A2|A1| | |
538 +|(% rowspan="2" %)Byte2|Bit15|Bit14|Bit13|Bit12|Bit11|Bit10|Bit9|Bit8
539 +| | |Solar Radiation|PAR|PM10|PM2.5|(((
540 +Rain
547 547  
542 +Gauge
543 +)))|(((
544 +Air
545 +
546 +Pressure
547 +)))
548 +|(% rowspan="2" %)Byte1|Bit7|Bit6|Bit5|Bit4|Bit3|Bit2|Bit1|Bit0
549 +|Humidity|Temperature|CO2|(((
550 +Rain/Snow
551 +
552 +Detect
553 +)))|illuminance|(((
554 +Wind
555 +
556 +Direction
557 +)))|Wind Speed|BAT
558 +
548 548  (% style="color:#037691" %)**AT Command:**
549 549  
550 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:377px" %)
551 -|=(% style="width: 157px;" %)**Command Example**|=(% style="width: 130px;" %)**Function**|=(% style="width: 87px;" %)**Response**
552 -|(% style="width:157px" %)AT+STYPE=80221|(% style="width:130px" %)Set sensor types|(% style="width:87px" %)OK
561 +|**Command Example**|**Function**|**Response**
562 +|AT+STYPE=80221|Set sensor types|OK
553 553  
554 554  Eg: The setting command **AT+STYPE=802212** means:
555 555  
556 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:495px" %)
557 -|(% rowspan="2" style="width:57px" %)Byte3|(% style="width:57px" %)Bit23|(% style="width:59px" %)Bit22|(% style="width:56px" %)Bit21|(% style="width:51px" %)Bit20|(% style="width:54px" %)Bit19|(% style="width:54px" %)Bit18|(% style="width:52px" %)Bit17|(% style="width:52px" %)Bit16
558 -|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)0|(% style="width:51px" %)0|(% style="width:54px" %)1|(% style="width:54px" %)0|(% style="width:52px" %)0|(% style="width:52px" %)0
559 -|(% rowspan="2" style="width:57px" %)Byte2|(% style="width:57px" %)Bit15|(% style="width:59px" %)Bit14|(% style="width:56px" %)Bit13|(% style="width:51px" %)Bit12|(% style="width:54px" %)Bit11|(% style="width:54px" %)Bit10|(% style="width:52px" %)Bit9|(% style="width:52px" %)Bit8
560 -|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)0|(% style="width:51px" %)0|(% style="width:54px" %)0|(% style="width:54px" %)0|(% style="width:52px" %)1|(% style="width:52px" %)0
561 -|(% rowspan="2" style="width:57px" %)Byte1|(% style="width:57px" %)Bit7|(% style="width:59px" %)Bit6|(% style="width:56px" %)Bit5|(% style="width:51px" %)Bit4|(% style="width:54px" %)Bit3|(% style="width:54px" %)Bit2|(% style="width:52px" %)Bit1|(% style="width:52px" %)Bit0
562 -|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)1|(% style="width:51px" %)0|(% style="width:54px" %)0|(% style="width:54px" %)0|(% style="width:52px" %)0|(% style="width:52px" %)1
566 +|(% rowspan="2" %)Byte3|Bit23|Bit22|Bit21|Bit20|Bit19|Bit18|Bit17|Bit16
567 +|0|0|0|0|1|0|0|0
568 +|(% rowspan="2" %)Byte2|Bit15|Bit14|Bit13|Bit12|Bit11|Bit10|Bit9|Bit8
569 +|0|0|0|0|0|0|1|0
570 +|(% rowspan="2" %)Byte1|Bit7|Bit6|Bit5|Bit4|Bit3|Bit2|Bit1|Bit0
571 +|0|0|1|0|0|0|0|1
563 563  
564 564  So wsc1-L will upload the following data: Custom Sensor A1, Rain Gauge,CO2,BAT.
565 565  
... ... @@ -570,11 +570,12 @@
570 570  
571 571  (% style="color:red" %)**Note:**
572 572  
573 -~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned.
582 +~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned
574 574  
575 575  
576 576  
577 577  
587 +
578 578  = 4. Power consumption and battery =
579 579  
580 580  == 4.1 Total Power Consumption ==
... ... @@ -587,15 +587,13 @@
587 587  The main process unit WSC1-L is set to LoRaWAN Class C by default. If user want to reduce the power consumption of this unit, user can set it to run in Class A. In Class A mode, WSC1-L will not be to get real-time downlink command from IoT Server.
588 588  
589 589  
600 +
590 590  == 4.3 Battery ==
591 591  
592 -(((
593 -All sensors are only power by external power source. If external power source is off. All sensor won't work.
594 -)))
603 +All sensors are only power by external power source. If external power source is off. All sensor won’t work.
595 595  
596 -(((
605 +
597 597  Main Process Unit WSC1-L is powered by both external power source and internal 1000mAh rechargeable battery. If external power source is off, WSC1-L still runs and can send periodically uplinks, but the sensors value will become invalid.  External power source can recharge the 1000mAh rechargeable battery.
598 -)))
599 599  
600 600  
601 601  
... ... @@ -615,8 +615,6 @@
615 615  * IP Rating: IP65
616 616  * Support default sensors or 3rd party RS485 sensors
617 617  
618 -
619 -
620 620  == 5.2 Power Consumption ==
621 621  
622 622  WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA
image-20220624144904-12.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -17.2 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0