Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/04/25 09:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -77,8 +77,6 @@ 77 77 * Mounting Kit includes pole and mast assembly. Each weather sensor has it’s own mounting assembly, user can check the sensor section in this manual. 78 78 * Cabinet. 79 79 80 - 81 - 82 82 == 2.2 How it works? == 83 83 84 84 ((( ... ... @@ -96,8 +96,6 @@ 96 96 1. WSC1-L will auto scan available weather sensors when power on or reboot. 97 97 1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors. 98 98 99 - 100 - 101 101 == 2.3 Example to use for LoRaWAN network == 102 102 103 103 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. ... ... @@ -154,7 +154,6 @@ 154 154 * Valid Sensor Value: Use FPORT=2 155 155 * Other control command: Use FPORT other than 2. 156 156 157 - 158 158 === 2.4.1 Uplink FPORT~=5, Device Status === 159 159 160 160 Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours ... ... @@ -379,7 +379,6 @@ 379 379 These commands only valid for WSC1-L, as below: 380 380 381 381 382 - 383 383 == 3.1 Set Transmit Interval Time == 384 384 385 385 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -400,7 +400,6 @@ 400 400 401 401 402 402 403 - 404 404 == 3.2 Set Emergency Mode == 405 405 406 406 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. ... ... @@ -417,7 +417,6 @@ 417 417 418 418 419 419 420 - 421 421 == 3.3 Add or Delete RS485 Sensor == 422 422 423 423 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. ... ... @@ -435,7 +435,6 @@ 435 435 * timeout: RS485 receive timeout (uint:ms). Device will close receive window after timeout 436 436 437 437 438 - 439 439 **Example:** 440 440 441 441 User need to change external sensor use the type code as address code. ... ... @@ -491,7 +491,6 @@ 491 491 492 492 493 493 494 - 495 495 == 3.4 RS485 Test Command == 496 496 497 497 (% style="color:#037691" %)**AT Command:** ... ... @@ -515,7 +515,6 @@ 515 515 516 516 517 517 518 - 519 519 == 3.5 RS485 response timeout == 520 520 521 521 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -542,16 +542,16 @@ 542 542 543 543 544 544 545 - 546 546 == 3.6 Set Sensor Type == 547 547 548 548 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values. 549 549 550 -See [[definition>>||anchor="H WeatherSensorTypes:"]] for the sensor type.538 +See [[definition>>||anchor="H"]] for the sensor type. 551 551 552 552 [[image:image-20220624144904-12.png]] 553 553 554 554 543 + 555 555 (% style="color:#037691" %)**AT Command:** 556 556 557 557 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:377px" %) ... ... @@ -558,6 +558,7 @@ 558 558 |=(% style="width: 157px;" %)**Command Example**|=(% style="width: 130px;" %)**Function**|=(% style="width: 87px;" %)**Response** 559 559 |(% style="width:157px" %)AT+STYPE=80221|(% style="width:130px" %)Set sensor types|(% style="width:87px" %)OK 560 560 550 + 561 561 Eg: The setting command **AT+STYPE=802212** means: 562 562 563 563 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:495px" %) ... ... @@ -582,6 +582,7 @@ 582 582 583 583 584 584 575 + 585 585 = 4. Power consumption and battery = 586 586 587 587 == 4.1 Total Power Consumption == ... ... @@ -594,15 +594,13 @@ 594 594 The main process unit WSC1-L is set to LoRaWAN Class C by default. If user want to reduce the power consumption of this unit, user can set it to run in Class A. In Class A mode, WSC1-L will not be to get real-time downlink command from IoT Server. 595 595 596 596 588 + 597 597 == 4.3 Battery == 598 598 599 -((( 600 -All sensors are only power by external power source. If external power source is off. All sensor won't work. 601 -))) 591 +All sensors are only power by external power source. If external power source is off. All sensor won’t work. 602 602 603 - (((593 + 604 604 Main Process Unit WSC1-L is powered by both external power source and internal 1000mAh rechargeable battery. If external power source is off, WSC1-L still runs and can send periodically uplinks, but the sensors value will become invalid. External power source can recharge the 1000mAh rechargeable battery. 605 -))) 606 606 607 607 608 608 ... ... @@ -622,9 +622,6 @@ 622 622 * IP Rating: IP65 623 623 * Support default sensors or 3rd party RS485 sensors 624 624 625 - 626 - 627 - 628 628 == 5.2 Power Consumption == 629 629 630 630 WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA