Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Mengting Qiu on 2025/06/10 18:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -382,7 +382,6 @@ 382 382 These commands only valid for WSC1-L, as below: 383 383 384 384 385 - 386 386 == 3.1 Set Transmit Interval Time == 387 387 388 388 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -402,9 +402,6 @@ 402 402 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 403 403 404 404 405 - 406 - 407 - 408 408 == 3.2 Set Emergency Mode == 409 409 410 410 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. ... ... @@ -420,9 +420,6 @@ 420 420 * 0xE100 Same as: AT+ALARMMOD=0 421 421 422 422 423 - 424 - 425 - 426 426 == 3.3 Add or Delete RS485 Sensor == 427 427 428 428 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. ... ... @@ -492,9 +492,6 @@ 492 492 * 0xE5FF 493 493 494 494 495 - 496 - 497 - 498 498 == 3.4 RS485 Test Command == 499 499 500 500 (% style="color:#037691" %)**AT Command:** ... ... @@ -517,9 +517,6 @@ 517 517 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 518 518 519 519 520 - 521 - 522 - 523 523 == 3.5 RS485 response timeout == 524 524 525 525 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -544,9 +544,6 @@ 544 544 * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds 545 545 546 546 547 - 548 - 549 - 550 550 == 3.6 Set Sensor Type == 551 551 552 552 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.