Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/04/25 09:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -80,6 +80,7 @@ 80 80 81 81 82 82 83 + 83 83 == 2.2 How it works? == 84 84 85 85 ((( ... ... @@ -100,6 +100,7 @@ 100 100 101 101 102 102 104 + 103 103 == 2.3 Example to use for LoRaWAN network == 104 104 105 105 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. ... ... @@ -158,6 +158,7 @@ 158 158 159 159 160 160 163 + 161 161 === 2.4.1 Uplink FPORT~=5, Device Status === 162 162 163 163 Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours ... ... @@ -382,7 +382,6 @@ 382 382 These commands only valid for WSC1-L, as below: 383 383 384 384 385 - 386 386 == 3.1 Set Transmit Interval Time == 387 387 388 388 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -403,8 +403,6 @@ 403 403 404 404 405 405 406 - 407 - 408 408 == 3.2 Set Emergency Mode == 409 409 410 410 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. ... ... @@ -421,8 +421,6 @@ 421 421 422 422 423 423 424 - 425 - 426 426 == 3.3 Add or Delete RS485 Sensor == 427 427 428 428 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. ... ... @@ -439,6 +439,7 @@ 439 439 * has_CRC: RS485 Response crc check (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0. 440 440 * timeout: RS485 receive timeout (uint:ms). Device will close receive window after timeout 441 441 440 + 442 442 **Example:** 443 443 444 444 User need to change external sensor use the type code as address code. ... ... @@ -463,6 +463,7 @@ 463 463 * has_CRC: 1 464 464 * timeout: 1500 (Fill in the test according to the actual situation) 465 465 465 + 466 466 **So the input command is:** 467 467 468 468 AT+DYSENSOR=A1,8,A103000000019CAA,8,24,1,1500 ... ... @@ -493,8 +493,6 @@ 493 493 494 494 495 495 496 - 497 - 498 498 == 3.4 RS485 Test Command == 499 499 500 500 (% style="color:#037691" %)**AT Command:** ... ... @@ -518,8 +518,6 @@ 518 518 519 519 520 520 521 - 522 - 523 523 == 3.5 RS485 response timeout == 524 524 525 525 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -534,6 +534,7 @@ 534 534 Range : 0~~10000 535 535 )))|(% style="width:85px" %)OK 536 536 533 + 537 537 (% style="color:#037691" %)**Downlink Command:** 538 538 539 539 Format: Command Code (0xE0) followed by 3 bytes time value. ... ... @@ -545,13 +545,11 @@ 545 545 546 546 547 547 548 - 549 - 550 550 == 3.6 Set Sensor Type == 551 551 552 552 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values. 553 553 554 -See [[definition>>||anchor="H WeatherSensorTypes:"]] for the sensor type.549 +See [[definition>>||anchor="H"]] for the sensor type. 555 555 556 556 [[image:image-20220624144904-12.png]] 557 557 ... ... @@ -563,6 +563,7 @@ 563 563 |=(% style="width: 157px;" %)**Command Example**|=(% style="width: 130px;" %)**Function**|=(% style="width: 87px;" %)**Response** 564 564 |(% style="width:157px" %)AT+STYPE=80221|(% style="width:130px" %)Set sensor types|(% style="width:87px" %)OK 565 565 561 + 566 566 Eg: The setting command **AT+STYPE=802212** means: 567 567 568 568 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:495px" %) ... ... @@ -599,15 +599,13 @@ 599 599 The main process unit WSC1-L is set to LoRaWAN Class C by default. If user want to reduce the power consumption of this unit, user can set it to run in Class A. In Class A mode, WSC1-L will not be to get real-time downlink command from IoT Server. 600 600 601 601 598 + 602 602 == 4.3 Battery == 603 603 604 -((( 605 -All sensors are only power by external power source. If external power source is off. All sensor won't work. 606 -))) 601 +All sensors are only power by external power source. If external power source is off. All sensor won’t work. 607 607 608 - (((603 + 609 609 Main Process Unit WSC1-L is powered by both external power source and internal 1000mAh rechargeable battery. If external power source is off, WSC1-L still runs and can send periodically uplinks, but the sensors value will become invalid. External power source can recharge the 1000mAh rechargeable battery. 610 -))) 611 611 612 612 613 613 ... ... @@ -627,10 +627,6 @@ 627 627 * IP Rating: IP65 628 628 * Support default sensors or 3rd party RS485 sensors 629 629 630 - 631 - 632 - 633 - 634 634 == 5.2 Power Consumption == 635 635 636 636 WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA