Last modified by Mengting Qiu on 2025/06/10 18:53

From version 32.10
edited by Xiaoling
on 2022/06/24 14:59
Change comment: There is no comment for this version
To version 32.12
edited by Xiaoling
on 2022/06/24 15:00
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -78,8 +78,6 @@
78 78  * Cabinet.
79 79  
80 80  
81 -
82 -
83 83  == 2.2 How it works? ==
84 84  
85 85  (((
... ... @@ -98,8 +98,6 @@
98 98  1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors.
99 99  
100 100  
101 -
102 -
103 103  == 2.3 Example to use for LoRaWAN network ==
104 104  
105 105  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -158,6 +158,8 @@
158 158  
159 159  
160 160  
157 +
158 +
161 161  === 2.4.1 Uplink FPORT~=5, Device Status ===
162 162  
163 163  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -403,8 +403,6 @@
403 403  
404 404  
405 405  
406 -
407 -
408 408  == 3.2 Set Emergency Mode ==
409 409  
410 410  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
... ... @@ -421,8 +421,6 @@
421 421  
422 422  
423 423  
424 -
425 -
426 426  == 3.3 Add or Delete RS485 Sensor ==
427 427  
428 428  Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors.
... ... @@ -439,6 +439,7 @@
439 439  * has_CRC:  RS485 Response crc check  (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0.
440 440  * timeout:  RS485 receive timeout (uint:ms). Device will close receive window after timeout
441 441  
436 +
442 442  **Example:**
443 443  
444 444  User need to change external sensor use the type code as address code.
... ... @@ -493,8 +493,6 @@
493 493  
494 494  
495 495  
496 -
497 -
498 498  == 3.4 RS485 Test Command ==
499 499  
500 500  (% style="color:#037691" %)**AT Command:**
... ... @@ -518,8 +518,6 @@
518 518  
519 519  
520 520  
521 -
522 -
523 523  == 3.5 RS485 response timeout ==
524 524  
525 525  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -545,8 +545,6 @@
545 545  
546 546  
547 547  
548 -
549 -
550 550  == 3.6 Set Sensor Type ==
551 551  
552 552  Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.
... ... @@ -556,7 +556,6 @@
556 556  [[image:image-20220624144904-12.png]]
557 557  
558 558  
559 -
560 560  (% style="color:#037691" %)**AT Command:**
561 561  
562 562  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:377px" %)
... ... @@ -629,8 +629,6 @@
629 629  
630 630  
631 631  
632 -
633 -
634 634  == 5.2 Power Consumption ==
635 635  
636 636  WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA