Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/04/25 09:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -77,6 +77,7 @@ 77 77 * Mounting Kit includes pole and mast assembly. Each weather sensor has it’s own mounting assembly, user can check the sensor section in this manual. 78 78 * Cabinet. 79 79 80 + 80 80 == 2.2 How it works? == 81 81 82 82 ((( ... ... @@ -94,6 +94,7 @@ 94 94 1. WSC1-L will auto scan available weather sensors when power on or reboot. 95 95 1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors. 96 96 98 + 97 97 == 2.3 Example to use for LoRaWAN network == 98 98 99 99 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. ... ... @@ -394,6 +394,7 @@ 394 394 395 395 396 396 399 + 397 397 == 3.2 Set Emergency Mode == 398 398 399 399 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. ... ... @@ -410,6 +410,7 @@ 410 410 411 411 412 412 416 + 413 413 == 3.3 Add or Delete RS485 Sensor == 414 414 415 415 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. ... ... @@ -416,7 +416,7 @@ 416 416 417 417 (% style="color:#037691" %)**AT Command: ** 418 418 419 - (% style="color:blue" %)**AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout**423 +**AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout** 420 420 421 421 * Type_Code range: A1 ~~ A4 422 422 * Query_Length: RS485 Query frame length, Value cannot be greater than 10 ... ... @@ -441,7 +441,7 @@ 441 441 [[image:image-20220624143618-11.png]] 442 442 443 443 444 - **Then the following parameters should be:**448 +Then the following parameters should be: 445 445 446 446 * Address_Code range: A1 447 447 * Query_Length: 8 ... ... @@ -452,7 +452,7 @@ 452 452 * timeout: 1500 (Fill in the test according to the actual situation) 453 453 454 454 455 - **So the input command is:**459 +So the input command is: 456 456 457 457 AT+DYSENSOR=A1,8,A103000000019CAA,8,24,1,1500 458 458 ... ... @@ -459,15 +459,14 @@ 459 459 460 460 In every sampling. WSC1-L will auto append the sensor segment as per this structure and uplink. 461 461 462 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:351px" %) 463 -|=(% style="width: 94px;" %)Type Code|=(% style="width: 121px;" %)Length (Bytes)|=(% style="width: 132px;" %)Measured Value 464 -|(% style="width:94px" %)A1|(% style="width:121px" %)2|(% style="width:132px" %)0x000A 466 +|Type Code|Length (Bytes)|Measured Value 467 +|A1|2|0x000A 465 465 466 - **Related commands:**469 +Related commands: 467 467 468 -AT+DYSENSOR=A1,0 ~-~->471 +AT+DYSENSOR=A1,0 –> Delete 3^^rd^^ party sensor A1. 469 469 470 -AT+DYSENSOR 473 +AT+DYSENSOR ~-~-> List All 3^^rd^^ Party Sensor. Like below: 471 471 472 472 473 473 (% style="color:#037691" %)**Downlink Command: ** ... ... @@ -482,17 +482,17 @@ 482 482 483 483 484 484 488 + 485 485 == 3.4 RS485 Test Command == 486 486 487 487 (% style="color:#037691" %)**AT Command:** 488 488 489 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:474px" %) 490 -|=(% style="width: 159px;" %)**Command Example**|=(% style="width: 227px;" %)**Function**|=(% style="width: 85px;" %)**Response** 491 -|(% style="width:159px" %)AT+RSWRITE=xxxxxx|(% style="width:227px" %)((( 493 +|**Command Example**|**Function**|**Response** 494 +|AT+RSWRITE=xxxxxx|((( 492 492 Send command to 485 sensor 493 493 494 494 Range : no more than 10 bytes 495 -)))| (% style="width:85px" %)OK498 +)))|OK 496 496 497 497 Eg: Send command **01 03 00 00 00 01 84 0A** to 485 sensor 498 498 ... ... @@ -505,6 +505,7 @@ 505 505 506 506 507 507 511 + 508 508 == 3.5 RS485 response timeout == 509 509 510 510 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -511,15 +511,13 @@ 511 511 512 512 (% style="color:#037691" %)**AT Command:** 513 513 514 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:433px" %) 515 -|=(% style="width: 157px;" %)**Command Example**|=(% style="width: 188px;" %)**Function**|=(% style="width: 85px;" %)**Response** 516 -|(% style="width:157px" %)AT+DTR=1000|(% style="width:188px" %)((( 518 +|**Command Example**|**Function**|**Response** 519 +|AT+DTR=1000|((( 517 517 Set response timeout to: 518 518 519 519 Range : 0~~10000 520 -)))| (% style="width:85px" %)OK523 +)))|OK 521 521 522 - 523 523 (% style="color:#037691" %)**Downlink Command:** 524 524 525 525 Format: Command Code (0xE0) followed by 3 bytes time value. ... ... @@ -531,6 +531,7 @@ 531 531 532 532 533 533 536 + 534 534 == 3.6 Set Sensor Type == 535 535 536 536 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.
- image-20220624144904-12.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.2 KB - Content