From version < 31.7 >
edited by Xiaoling
on 2022/06/24 14:45
To version < 32.13 >
edited by Xiaoling
on 2022/06/24 15:01
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -150,6 +150,9 @@
150 150  * Valid Sensor Value: Use FPORT=2
151 151  * Other control command: Use FPORT other than 2.
152 152  
153 +
154 +
155 +
153 153  === 2.4.1 Uplink FPORT~=5, Device Status ===
154 154  
155 155  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -393,7 +393,6 @@
393 393  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
394 394  
395 395  
396 -
397 397  == 3.2 Set Emergency Mode ==
398 398  
399 399  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
... ... @@ -409,7 +409,6 @@
409 409  * 0xE100     Same as: AT+ALARMMOD=0
410 410  
411 411  
412 -
413 413  == 3.3 Add or Delete RS485 Sensor ==
414 414  
415 415  Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors.
... ... @@ -426,7 +426,6 @@
426 426  * has_CRC:  RS485 Response crc check  (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0.
427 427  * timeout:  RS485 receive timeout (uint:ms). Device will close receive window after timeout
428 428  
429 -
430 430  **Example:**
431 431  
432 432  User need to change external sensor use the type code as address code.
... ... @@ -451,7 +451,6 @@
451 451  * has_CRC: 1
452 452  * timeout: 1500 (Fill in the test according to the actual situation)
453 453  
454 -
455 455  **So the input command is:**
456 456  
457 457  AT+DYSENSOR=A1,8,A103000000019CAA,8,24,1,1500
... ... @@ -481,7 +481,6 @@
481 481  * 0xE5FF  
482 482  
483 483  
484 -
485 485  == 3.4 RS485 Test Command ==
486 486  
487 487  (% style="color:#037691" %)**AT Command:**
... ... @@ -504,7 +504,6 @@
504 504  * 0xE20103000001840A     Same as: AT+RSWRITE=0103000001840A
505 505  
506 506  
507 -
508 508  == 3.5 RS485 response timeout ==
509 509  
510 510  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -511,12 +511,13 @@
511 511  
512 512  (% style="color:#037691" %)**AT Command:**
513 513  
514 -|**Command Example**|**Function**|**Response**
515 -|AT+DTR=1000|(((
511 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:433px" %)
512 +|=(% style="width: 157px;" %)**Command Example**|=(% style="width: 188px;" %)**Function**|=(% style="width: 85px;" %)**Response**
513 +|(% style="width:157px" %)AT+DTR=1000|(% style="width:188px" %)(((
516 516  Set response timeout to:
517 517  
518 518  Range : 0~~10000
519 -)))|OK
517 +)))|(% style="width:85px" %)OK
520 520  
521 521  (% style="color:#037691" %)**Downlink Command:**
522 522  
... ... @@ -528,50 +528,30 @@
528 528  * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds
529 529  
530 530  
531 -
532 532  == 3.6 Set Sensor Type ==
533 533  
534 534  Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.
535 535  
536 -See [[definition>>||anchor="H"]] for the sensor type.
533 +See [[definition>>||anchor="HWeatherSensorTypes:"]] for the sensor type.
537 537  
535 +[[image:image-20220624144904-12.png]]
538 538  
539 -|(% rowspan="2" %)Byte3|Bit23|Bit22|Bit21|Bit20|Bit19|Bit18|Bit17|Bit16
540 -| |A4|A3|A2|A1| | |
541 -|(% rowspan="2" %)Byte2|Bit15|Bit14|Bit13|Bit12|Bit11|Bit10|Bit9|Bit8
542 -| | |Solar Radiation|PAR|PM10|PM2.5|(((
543 -Rain
544 544  
545 -Gauge
546 -)))|(((
547 -Air
548 -
549 -Pressure
550 -)))
551 -|(% rowspan="2" %)Byte1|Bit7|Bit6|Bit5|Bit4|Bit3|Bit2|Bit1|Bit0
552 -|Humidity|Temperature|CO2|(((
553 -Rain/Snow
554 -
555 -Detect
556 -)))|illuminance|(((
557 -Wind
558 -
559 -Direction
560 -)))|Wind Speed|BAT
561 -
562 562  (% style="color:#037691" %)**AT Command:**
563 563  
564 -|**Command Example**|**Function**|**Response**
565 -|AT+STYPE=80221|Set sensor types|OK
540 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:377px" %)
541 +|=(% style="width: 157px;" %)**Command Example**|=(% style="width: 130px;" %)**Function**|=(% style="width: 87px;" %)**Response**
542 +|(% style="width:157px" %)AT+STYPE=80221|(% style="width:130px" %)Set sensor types|(% style="width:87px" %)OK
566 566  
567 567  Eg: The setting command **AT+STYPE=802212** means:
568 568  
569 -|(% rowspan="2" %)Byte3|Bit23|Bit22|Bit21|Bit20|Bit19|Bit18|Bit17|Bit16
570 -|0|0|0|0|1|0|0|0
571 -|(% rowspan="2" %)Byte2|Bit15|Bit14|Bit13|Bit12|Bit11|Bit10|Bit9|Bit8
572 -|0|0|0|0|0|0|1|0
573 -|(% rowspan="2" %)Byte1|Bit7|Bit6|Bit5|Bit4|Bit3|Bit2|Bit1|Bit0
574 -|0|0|1|0|0|0|0|1
546 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:495px" %)
547 +|(% rowspan="2" style="width:57px" %)Byte3|(% style="width:57px" %)Bit23|(% style="width:59px" %)Bit22|(% style="width:56px" %)Bit21|(% style="width:51px" %)Bit20|(% style="width:54px" %)Bit19|(% style="width:54px" %)Bit18|(% style="width:52px" %)Bit17|(% style="width:52px" %)Bit16
548 +|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)0|(% style="width:51px" %)0|(% style="width:54px" %)1|(% style="width:54px" %)0|(% style="width:52px" %)0|(% style="width:52px" %)0
549 +|(% rowspan="2" style="width:57px" %)Byte2|(% style="width:57px" %)Bit15|(% style="width:59px" %)Bit14|(% style="width:56px" %)Bit13|(% style="width:51px" %)Bit12|(% style="width:54px" %)Bit11|(% style="width:54px" %)Bit10|(% style="width:52px" %)Bit9|(% style="width:52px" %)Bit8
550 +|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)0|(% style="width:51px" %)0|(% style="width:54px" %)0|(% style="width:54px" %)0|(% style="width:52px" %)1|(% style="width:52px" %)0
551 +|(% rowspan="2" style="width:57px" %)Byte1|(% style="width:57px" %)Bit7|(% style="width:59px" %)Bit6|(% style="width:56px" %)Bit5|(% style="width:51px" %)Bit4|(% style="width:54px" %)Bit3|(% style="width:54px" %)Bit2|(% style="width:52px" %)Bit1|(% style="width:52px" %)Bit0
552 +|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)1|(% style="width:51px" %)0|(% style="width:54px" %)0|(% style="width:54px" %)0|(% style="width:52px" %)0|(% style="width:52px" %)1
575 575  
576 576  So wsc1-L will upload the following data: Custom Sensor A1, Rain Gauge,CO2,BAT.
577 577  
... ... @@ -582,12 +582,11 @@
582 582  
583 583  (% style="color:red" %)**Note:**
584 584  
585 -~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned
563 +~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned.
586 586  
587 587  
588 588  
589 589  
590 -
591 591  = 4. Power consumption and battery =
592 592  
593 593  == 4.1 Total Power Consumption ==
... ... @@ -600,13 +600,15 @@
600 600  The main process unit WSC1-L is set to LoRaWAN Class C by default. If user want to reduce the power consumption of this unit, user can set it to run in Class A. In Class A mode, WSC1-L will not be to get real-time downlink command from IoT Server.
601 601  
602 602  
603 -
604 604  == 4.3 Battery ==
605 605  
606 -All sensors are only power by external power source. If external power source is off. All sensor won’t work.
582 +(((
583 +All sensors are only power by external power source. If external power source is off. All sensor won't work.
584 +)))
607 607  
608 -
586 +(((
609 609  Main Process Unit WSC1-L is powered by both external power source and internal 1000mAh rechargeable battery. If external power source is off, WSC1-L still runs and can send periodically uplinks, but the sensors value will become invalid.  External power source can recharge the 1000mAh rechargeable battery.
588 +)))
610 610  
611 611  
612 612  
... ... @@ -626,6 +626,7 @@
626 626  * IP Rating: IP65
627 627  * Support default sensors or 3rd party RS485 sensors
628 628  
608 +
629 629  == 5.2 Power Consumption ==
630 630  
631 631  WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA
image-20220624144904-12.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +17.2 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0