Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/04/25 09:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -150,6 +150,9 @@ 150 150 * Valid Sensor Value: Use FPORT=2 151 151 * Other control command: Use FPORT other than 2. 152 152 153 + 154 + 155 + 153 153 === 2.4.1 Uplink FPORT~=5, Device Status === 154 154 155 155 Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours ... ... @@ -393,7 +393,6 @@ 393 393 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 394 394 395 395 396 - 397 397 == 3.2 Set Emergency Mode == 398 398 399 399 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. ... ... @@ -409,7 +409,6 @@ 409 409 * 0xE100 Same as: AT+ALARMMOD=0 410 410 411 411 412 - 413 413 == 3.3 Add or Delete RS485 Sensor == 414 414 415 415 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. ... ... @@ -426,7 +426,6 @@ 426 426 * has_CRC: RS485 Response crc check (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0. 427 427 * timeout: RS485 receive timeout (uint:ms). Device will close receive window after timeout 428 428 429 - 430 430 **Example:** 431 431 432 432 User need to change external sensor use the type code as address code. ... ... @@ -451,7 +451,6 @@ 451 451 * has_CRC: 1 452 452 * timeout: 1500 (Fill in the test according to the actual situation) 453 453 454 - 455 455 **So the input command is:** 456 456 457 457 AT+DYSENSOR=A1,8,A103000000019CAA,8,24,1,1500 ... ... @@ -481,17 +481,17 @@ 481 481 * 0xE5FF 482 482 483 483 484 - 485 485 == 3.4 RS485 Test Command == 486 486 487 487 (% style="color:#037691" %)**AT Command:** 488 488 489 -|**Command Example**|**Function**|**Response** 490 -|AT+RSWRITE=xxxxxx|((( 487 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:474px" %) 488 +|=(% style="width: 159px;" %)**Command Example**|=(% style="width: 227px;" %)**Function**|=(% style="width: 85px;" %)**Response** 489 +|(% style="width:159px" %)AT+RSWRITE=xxxxxx|(% style="width:227px" %)((( 491 491 Send command to 485 sensor 492 492 493 493 Range : no more than 10 bytes 494 -)))|OK 493 +)))|(% style="width:85px" %)OK 495 495 496 496 Eg: Send command **01 03 00 00 00 01 84 0A** to 485 sensor 497 497 ... ... @@ -503,7 +503,6 @@ 503 503 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 504 504 505 505 506 - 507 507 == 3.5 RS485 response timeout == 508 508 509 509 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -510,12 +510,13 @@ 510 510 511 511 (% style="color:#037691" %)**AT Command:** 512 512 513 -|**Command Example**|**Function**|**Response** 514 -|AT+DTR=1000|((( 511 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:433px" %) 512 +|=(% style="width: 157px;" %)**Command Example**|=(% style="width: 188px;" %)**Function**|=(% style="width: 85px;" %)**Response** 513 +|(% style="width:157px" %)AT+DTR=1000|(% style="width:188px" %)((( 515 515 Set response timeout to: 516 516 517 517 Range : 0~~10000 518 -)))|OK 517 +)))|(% style="width:85px" %)OK 519 519 520 520 (% style="color:#037691" %)**Downlink Command:** 521 521 ... ... @@ -527,50 +527,30 @@ 527 527 * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds 528 528 529 529 530 - 531 531 == 3.6 Set Sensor Type == 532 532 533 533 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values. 534 534 535 -See [[definition>>||anchor="H"]] for the sensor type. 533 +See [[definition>>||anchor="HWeatherSensorTypes:"]] for the sensor type. 536 536 535 +[[image:image-20220624144904-12.png]] 537 537 538 -|(% rowspan="2" %)Byte3|Bit23|Bit22|Bit21|Bit20|Bit19|Bit18|Bit17|Bit16 539 -| |A4|A3|A2|A1| | | 540 -|(% rowspan="2" %)Byte2|Bit15|Bit14|Bit13|Bit12|Bit11|Bit10|Bit9|Bit8 541 -| | |Solar Radiation|PAR|PM10|PM2.5|((( 542 -Rain 543 543 544 -Gauge 545 -)))|((( 546 -Air 547 - 548 -Pressure 549 -))) 550 -|(% rowspan="2" %)Byte1|Bit7|Bit6|Bit5|Bit4|Bit3|Bit2|Bit1|Bit0 551 -|Humidity|Temperature|CO2|((( 552 -Rain/Snow 553 - 554 -Detect 555 -)))|illuminance|((( 556 -Wind 557 - 558 -Direction 559 -)))|Wind Speed|BAT 560 - 561 561 (% style="color:#037691" %)**AT Command:** 562 562 563 -|**Command Example**|**Function**|**Response** 564 -|AT+STYPE=80221|Set sensor types|OK 540 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:377px" %) 541 +|=(% style="width: 157px;" %)**Command Example**|=(% style="width: 130px;" %)**Function**|=(% style="width: 87px;" %)**Response** 542 +|(% style="width:157px" %)AT+STYPE=80221|(% style="width:130px" %)Set sensor types|(% style="width:87px" %)OK 565 565 566 566 Eg: The setting command **AT+STYPE=802212** means: 567 567 568 -|(% rowspan="2" %)Byte3|Bit23|Bit22|Bit21|Bit20|Bit19|Bit18|Bit17|Bit16 569 -|0|0|0|0|1|0|0|0 570 -|(% rowspan="2" %)Byte2|Bit15|Bit14|Bit13|Bit12|Bit11|Bit10|Bit9|Bit8 571 -|0|0|0|0|0|0|1|0 572 -|(% rowspan="2" %)Byte1|Bit7|Bit6|Bit5|Bit4|Bit3|Bit2|Bit1|Bit0 573 -|0|0|1|0|0|0|0|1 546 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:495px" %) 547 +|(% rowspan="2" style="width:57px" %)Byte3|(% style="width:57px" %)Bit23|(% style="width:59px" %)Bit22|(% style="width:56px" %)Bit21|(% style="width:51px" %)Bit20|(% style="width:54px" %)Bit19|(% style="width:54px" %)Bit18|(% style="width:52px" %)Bit17|(% style="width:52px" %)Bit16 548 +|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)0|(% style="width:51px" %)0|(% style="width:54px" %)1|(% style="width:54px" %)0|(% style="width:52px" %)0|(% style="width:52px" %)0 549 +|(% rowspan="2" style="width:57px" %)Byte2|(% style="width:57px" %)Bit15|(% style="width:59px" %)Bit14|(% style="width:56px" %)Bit13|(% style="width:51px" %)Bit12|(% style="width:54px" %)Bit11|(% style="width:54px" %)Bit10|(% style="width:52px" %)Bit9|(% style="width:52px" %)Bit8 550 +|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)0|(% style="width:51px" %)0|(% style="width:54px" %)0|(% style="width:54px" %)0|(% style="width:52px" %)1|(% style="width:52px" %)0 551 +|(% rowspan="2" style="width:57px" %)Byte1|(% style="width:57px" %)Bit7|(% style="width:59px" %)Bit6|(% style="width:56px" %)Bit5|(% style="width:51px" %)Bit4|(% style="width:54px" %)Bit3|(% style="width:54px" %)Bit2|(% style="width:52px" %)Bit1|(% style="width:52px" %)Bit0 552 +|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)1|(% style="width:51px" %)0|(% style="width:54px" %)0|(% style="width:54px" %)0|(% style="width:52px" %)0|(% style="width:52px" %)1 574 574 575 575 So wsc1-L will upload the following data: Custom Sensor A1, Rain Gauge,CO2,BAT. 576 576 ... ... @@ -581,12 +581,11 @@ 581 581 582 582 (% style="color:red" %)**Note:** 583 583 584 -~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned 563 +~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned. 585 585 586 586 587 587 588 588 589 - 590 590 = 4. Power consumption and battery = 591 591 592 592 == 4.1 Total Power Consumption == ... ... @@ -599,13 +599,15 @@ 599 599 The main process unit WSC1-L is set to LoRaWAN Class C by default. If user want to reduce the power consumption of this unit, user can set it to run in Class A. In Class A mode, WSC1-L will not be to get real-time downlink command from IoT Server. 600 600 601 601 602 - 603 603 == 4.3 Battery == 604 604 605 -All sensors are only power by external power source. If external power source is off. All sensor won’t work. 582 +((( 583 +All sensors are only power by external power source. If external power source is off. All sensor won't work. 584 +))) 606 606 607 - 586 +((( 608 608 Main Process Unit WSC1-L is powered by both external power source and internal 1000mAh rechargeable battery. If external power source is off, WSC1-L still runs and can send periodically uplinks, but the sensors value will become invalid. External power source can recharge the 1000mAh rechargeable battery. 588 +))) 609 609 610 610 611 611 ... ... @@ -625,6 +625,7 @@ 625 625 * IP Rating: IP65 626 626 * Support default sensors or 3rd party RS485 sensors 627 627 608 + 628 628 == 5.2 Power Consumption == 629 629 630 630 WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA
- image-20220624144904-12.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.2 KB - Content