Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/04/25 09:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -77,6 +77,7 @@ 77 77 * Mounting Kit includes pole and mast assembly. Each weather sensor has it’s own mounting assembly, user can check the sensor section in this manual. 78 78 * Cabinet. 79 79 80 + 80 80 == 2.2 How it works? == 81 81 82 82 ((( ... ... @@ -94,6 +94,7 @@ 94 94 1. WSC1-L will auto scan available weather sensors when power on or reboot. 95 95 1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors. 96 96 98 + 97 97 == 2.3 Example to use for LoRaWAN network == 98 98 99 99 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. ... ... @@ -394,6 +394,7 @@ 394 394 395 395 396 396 399 + 397 397 == 3.2 Set Emergency Mode == 398 398 399 399 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. ... ... @@ -410,6 +410,7 @@ 410 410 411 411 412 412 416 + 413 413 == 3.3 Add or Delete RS485 Sensor == 414 414 415 415 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. ... ... @@ -416,7 +416,7 @@ 416 416 417 417 (% style="color:#037691" %)**AT Command: ** 418 418 419 - (% style="color:blue" %)**AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout**423 +**AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout** 420 420 421 421 * Type_Code range: A1 ~~ A4 422 422 * Query_Length: RS485 Query frame length, Value cannot be greater than 10 ... ... @@ -451,6 +451,7 @@ 451 451 * has_CRC: 1 452 452 * timeout: 1500 (Fill in the test according to the actual situation) 453 453 458 + 454 454 So the input command is: 455 455 456 456 AT+DYSENSOR=A1,8,A103000000019CAA,8,24,1,1500 ... ... @@ -458,15 +458,14 @@ 458 458 459 459 In every sampling. WSC1-L will auto append the sensor segment as per this structure and uplink. 460 460 461 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:351px" %) 462 -|=(% style="width: 94px;" %)Type Code|=(% style="width: 121px;" %)Length (Bytes)|=(% style="width: 132px;" %)Measured Value 463 -|(% style="width:94px" %)A1|(% style="width:121px" %)2|(% style="width:132px" %)0x000A 466 +|Type Code|Length (Bytes)|Measured Value 467 +|A1|2|0x000A 464 464 465 465 Related commands: 466 466 467 -AT+DYSENSOR=A1,0 ~-~->471 +AT+DYSENSOR=A1,0 –> Delete 3^^rd^^ party sensor A1. 468 468 469 -AT+DYSENSOR 473 +AT+DYSENSOR ~-~-> List All 3^^rd^^ Party Sensor. Like below: 470 470 471 471 472 472 (% style="color:#037691" %)**Downlink Command: ** ... ... @@ -481,6 +481,7 @@ 481 481 482 482 483 483 488 + 484 484 == 3.4 RS485 Test Command == 485 485 486 486 (% style="color:#037691" %)**AT Command:** ... ... @@ -503,6 +503,7 @@ 503 503 504 504 505 505 511 + 506 506 == 3.5 RS485 response timeout == 507 507 508 508 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -527,6 +527,7 @@ 527 527 528 528 529 529 536 + 530 530 == 3.6 Set Sensor Type == 531 531 532 532 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.