Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Mengting Qiu on 2025/06/10 18:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -77,6 +77,7 @@ 77 77 * Mounting Kit includes pole and mast assembly. Each weather sensor has it’s own mounting assembly, user can check the sensor section in this manual. 78 78 * Cabinet. 79 79 80 + 80 80 == 2.2 How it works? == 81 81 82 82 ((( ... ... @@ -94,6 +94,7 @@ 94 94 1. WSC1-L will auto scan available weather sensors when power on or reboot. 95 95 1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors. 96 96 98 + 97 97 == 2.3 Example to use for LoRaWAN network == 98 98 99 99 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. ... ... @@ -150,6 +150,10 @@ 150 150 * Valid Sensor Value: Use FPORT=2 151 151 * Other control command: Use FPORT other than 2. 152 152 155 + 156 + 157 + 158 + 153 153 === 2.4.1 Uplink FPORT~=5, Device Status === 154 154 155 155 Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours ... ... @@ -374,6 +374,7 @@ 374 374 These commands only valid for WSC1-L, as below: 375 375 376 376 383 + 377 377 == 3.1 Set Transmit Interval Time == 378 378 379 379 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -441,7 +441,7 @@ 441 441 [[image:image-20220624143618-11.png]] 442 442 443 443 444 -Then the following parameters should be: 451 +**Then the following parameters should be:** 445 445 446 446 * Address_Code range: A1 447 447 * Query_Length: 8 ... ... @@ -451,7 +451,7 @@ 451 451 * has_CRC: 1 452 452 * timeout: 1500 (Fill in the test according to the actual situation) 453 453 454 -So the input command is: 461 +**So the input command is:** 455 455 456 456 AT+DYSENSOR=A1,8,A103000000019CAA,8,24,1,1500 457 457 ... ... @@ -458,14 +458,15 @@ 458 458 459 459 In every sampling. WSC1-L will auto append the sensor segment as per this structure and uplink. 460 460 461 -|Type Code|Length (Bytes)|Measured Value 462 -|A1|2|0x000A 468 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:351px" %) 469 +|=(% style="width: 94px;" %)Type Code|=(% style="width: 121px;" %)Length (Bytes)|=(% style="width: 132px;" %)Measured Value 470 +|(% style="width:94px" %)A1|(% style="width:121px" %)2|(% style="width:132px" %)0x000A 463 463 464 -Related commands: 472 +**Related commands:** 465 465 466 -AT+DYSENSOR=A1,0 –> Delete 3^^rd^^ party sensor A1.474 +AT+DYSENSOR=A1,0 ~-~-> Delete 3^^rd^^ party sensor A1. 467 467 468 -AT+DYSENSOR ~-~-> List All 3^^rd^^ Party Sensor. Like below: 476 +AT+DYSENSOR ~-~-> List All 3^^rd^^ Party Sensor. Like below: 469 469 470 470 471 471 (% style="color:#037691" %)**Downlink Command: ** ... ... @@ -484,12 +484,13 @@ 484 484 485 485 (% style="color:#037691" %)**AT Command:** 486 486 487 -|**Command Example**|**Function**|**Response** 488 -|AT+RSWRITE=xxxxxx|((( 495 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:474px" %) 496 +|=(% style="width: 159px;" %)**Command Example**|=(% style="width: 227px;" %)**Function**|=(% style="width: 85px;" %)**Response** 497 +|(% style="width:159px" %)AT+RSWRITE=xxxxxx|(% style="width:227px" %)((( 489 489 Send command to 485 sensor 490 490 491 491 Range : no more than 10 bytes 492 -)))|OK 501 +)))|(% style="width:85px" %)OK 493 493 494 494 Eg: Send command **01 03 00 00 00 01 84 0A** to 485 sensor 495 495 ... ... @@ -508,12 +508,13 @@ 508 508 509 509 (% style="color:#037691" %)**AT Command:** 510 510 511 -|**Command Example**|**Function**|**Response** 512 -|AT+DTR=1000|((( 520 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:433px" %) 521 +|=(% style="width: 157px;" %)**Command Example**|=(% style="width: 188px;" %)**Function**|=(% style="width: 85px;" %)**Response** 522 +|(% style="width:157px" %)AT+DTR=1000|(% style="width:188px" %)((( 513 513 Set response timeout to: 514 514 515 515 Range : 0~~10000 516 -)))|OK 526 +)))|(% style="width:85px" %)OK 517 517 518 518 (% style="color:#037691" %)**Downlink Command:** 519 519 ... ... @@ -530,45 +530,26 @@ 530 530 531 531 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values. 532 532 533 -See [[definition>>||anchor="H"]] for the sensor type. 543 +See [[definition>>||anchor="HWeatherSensorTypes:"]] for the sensor type. 534 534 545 +[[image:image-20220624144904-12.png]] 535 535 536 -|(% rowspan="2" %)Byte3|Bit23|Bit22|Bit21|Bit20|Bit19|Bit18|Bit17|Bit16 537 -| |A4|A3|A2|A1| | | 538 -|(% rowspan="2" %)Byte2|Bit15|Bit14|Bit13|Bit12|Bit11|Bit10|Bit9|Bit8 539 -| | |Solar Radiation|PAR|PM10|PM2.5|((( 540 -Rain 541 541 542 -Gauge 543 -)))|((( 544 -Air 545 - 546 -Pressure 547 -))) 548 -|(% rowspan="2" %)Byte1|Bit7|Bit6|Bit5|Bit4|Bit3|Bit2|Bit1|Bit0 549 -|Humidity|Temperature|CO2|((( 550 -Rain/Snow 551 - 552 -Detect 553 -)))|illuminance|((( 554 -Wind 555 - 556 -Direction 557 -)))|Wind Speed|BAT 558 - 559 559 (% style="color:#037691" %)**AT Command:** 560 560 561 -|**Command Example**|**Function**|**Response** 562 -|AT+STYPE=80221|Set sensor types|OK 550 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:377px" %) 551 +|=(% style="width: 157px;" %)**Command Example**|=(% style="width: 130px;" %)**Function**|=(% style="width: 87px;" %)**Response** 552 +|(% style="width:157px" %)AT+STYPE=80221|(% style="width:130px" %)Set sensor types|(% style="width:87px" %)OK 563 563 564 564 Eg: The setting command **AT+STYPE=802212** means: 565 565 566 -|(% rowspan="2" %)Byte3|Bit23|Bit22|Bit21|Bit20|Bit19|Bit18|Bit17|Bit16 567 -|0|0|0|0|1|0|0|0 568 -|(% rowspan="2" %)Byte2|Bit15|Bit14|Bit13|Bit12|Bit11|Bit10|Bit9|Bit8 569 -|0|0|0|0|0|0|1|0 570 -|(% rowspan="2" %)Byte1|Bit7|Bit6|Bit5|Bit4|Bit3|Bit2|Bit1|Bit0 571 -|0|0|1|0|0|0|0|1 556 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:495px" %) 557 +|(% rowspan="2" style="width:57px" %)Byte3|(% style="width:57px" %)Bit23|(% style="width:59px" %)Bit22|(% style="width:56px" %)Bit21|(% style="width:51px" %)Bit20|(% style="width:54px" %)Bit19|(% style="width:54px" %)Bit18|(% style="width:52px" %)Bit17|(% style="width:52px" %)Bit16 558 +|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)0|(% style="width:51px" %)0|(% style="width:54px" %)1|(% style="width:54px" %)0|(% style="width:52px" %)0|(% style="width:52px" %)0 559 +|(% rowspan="2" style="width:57px" %)Byte2|(% style="width:57px" %)Bit15|(% style="width:59px" %)Bit14|(% style="width:56px" %)Bit13|(% style="width:51px" %)Bit12|(% style="width:54px" %)Bit11|(% style="width:54px" %)Bit10|(% style="width:52px" %)Bit9|(% style="width:52px" %)Bit8 560 +|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)0|(% style="width:51px" %)0|(% style="width:54px" %)0|(% style="width:54px" %)0|(% style="width:52px" %)1|(% style="width:52px" %)0 561 +|(% rowspan="2" style="width:57px" %)Byte1|(% style="width:57px" %)Bit7|(% style="width:59px" %)Bit6|(% style="width:56px" %)Bit5|(% style="width:51px" %)Bit4|(% style="width:54px" %)Bit3|(% style="width:54px" %)Bit2|(% style="width:52px" %)Bit1|(% style="width:52px" %)Bit0 562 +|(% style="width:57px" %)0|(% style="width:59px" %)0|(% style="width:56px" %)1|(% style="width:51px" %)0|(% style="width:54px" %)0|(% style="width:54px" %)0|(% style="width:52px" %)0|(% style="width:52px" %)1 572 572 573 573 So wsc1-L will upload the following data: Custom Sensor A1, Rain Gauge,CO2,BAT. 574 574 ... ... @@ -579,12 +579,11 @@ 579 579 580 580 (% style="color:red" %)**Note:** 581 581 582 -~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned 573 +~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned. 583 583 584 584 585 585 586 586 587 - 588 588 = 4. Power consumption and battery = 589 589 590 590 == 4.1 Total Power Consumption == ... ... @@ -597,13 +597,15 @@ 597 597 The main process unit WSC1-L is set to LoRaWAN Class C by default. If user want to reduce the power consumption of this unit, user can set it to run in Class A. In Class A mode, WSC1-L will not be to get real-time downlink command from IoT Server. 598 598 599 599 600 - 601 601 == 4.3 Battery == 602 602 603 -All sensors are only power by external power source. If external power source is off. All sensor won’t work. 592 +((( 593 +All sensors are only power by external power source. If external power source is off. All sensor won't work. 594 +))) 604 604 605 - 596 +((( 606 606 Main Process Unit WSC1-L is powered by both external power source and internal 1000mAh rechargeable battery. If external power source is off, WSC1-L still runs and can send periodically uplinks, but the sensors value will become invalid. External power source can recharge the 1000mAh rechargeable battery. 598 +))) 607 607 608 608 609 609 ... ... @@ -623,6 +623,8 @@ 623 623 * IP Rating: IP65 624 624 * Support default sensors or 3rd party RS485 sensors 625 625 618 + 619 + 626 626 == 5.2 Power Consumption == 627 627 628 628 WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA
- image-20220624144904-12.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.2 KB - Content