From version < 31.2 >
edited by Xiaoling
on 2022/06/24 14:36
To version < 31.5 >
edited by Xiaoling
on 2022/06/24 14:43
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -77,7 +77,6 @@
77 77  * Mounting Kit includes pole and mast assembly. Each weather sensor has it’s own mounting assembly, user can check the sensor section in this manual.
78 78  * Cabinet.
79 79  
80 -
81 81  == 2.2 How it works? ==
82 82  
83 83  (((
... ... @@ -95,7 +95,6 @@
95 95  1. WSC1-L will auto scan available weather sensors when power on or reboot.
96 96  1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors.
97 97  
98 -
99 99  == 2.3 Example to use for LoRaWAN network ==
100 100  
101 101  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -396,7 +396,6 @@
396 396  
397 397  
398 398  
399 -
400 400  == 3.2 Set Emergency Mode ==
401 401  
402 402  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
... ... @@ -413,7 +413,6 @@
413 413  
414 414  
415 415  
416 -
417 417  == 3.3 Add or Delete RS485 Sensor ==
418 418  
419 419  Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors.
... ... @@ -420,7 +420,7 @@
420 420  
421 421  (% style="color:#037691" %)**AT Command: **
422 422  
423 -**AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout**
419 +(% style="color:blue" %)**AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout**
424 424  
425 425  * Type_Code range:  A1 ~~ A4
426 426  * Query_Length:  RS485 Query frame length, Value cannot be greater than 10
... ... @@ -462,14 +462,15 @@
462 462  
463 463  In every sampling. WSC1-L will auto append the sensor segment as per this structure and uplink.
464 464  
465 -|Type Code|Length (Bytes)|Measured Value
466 -|A1|2|0x000A
461 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:351px" %)
462 +|=(% style="width: 94px;" %)Type Code|=(% style="width: 121px;" %)Length (Bytes)|=(% style="width: 132px;" %)Measured Value
463 +|(% style="width:94px" %)A1|(% style="width:121px" %)2|(% style="width:132px" %)0x000A
467 467  
468 468  Related commands:
469 469  
470 -AT+DYSENSOR=A1,0 > Delete 3^^rd^^ party sensor A1.
467 +AT+DYSENSOR=A1,0  ~-~->  Delete 3^^rd^^ party sensor A1.
471 471  
472 -AT+DYSENSOR ~-~-> List All 3^^rd^^ Party Sensor. Like below:
469 +AT+DYSENSOR  ~-~->  List All 3^^rd^^ Party Sensor. Like below:
473 473  
474 474  
475 475  (% style="color:#037691" %)**Downlink Command:  **
... ... @@ -484,7 +484,6 @@
484 484  
485 485  
486 486  
487 -
488 488  == 3.4 RS485 Test Command ==
489 489  
490 490  (% style="color:#037691" %)**AT Command:**
... ... @@ -507,7 +507,6 @@
507 507  
508 508  
509 509  
510 -
511 511  == 3.5 RS485 response timeout ==
512 512  
513 513  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -532,7 +532,6 @@
532 532  
533 533  
534 534  
535 -
536 536  == 3.6 Set Sensor Type ==
537 537  
538 538  Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0