... ... @@ -67,6 +67,7 @@
67 67  * WSC1-L has an extra 1000mAh back up battery. So it can work even solar panel and storage battery Fails.
68 68  * Weather sensors won’t work if solar panel and storage battery fails.
69 69  
70 +
70 70  (% style="color:red" %)** Notice 2:**
71 71  
72 72  Due to shipment and importation limitation, user is better to purchase below parts locally:
... ... @@ -78,6 +78,7 @@
78 78  * Cabinet.
79 79  
80 80  
82 +
81 81  == 2.2 How it works? ==
82 82  
83 83  (((
... ... @@ -96,6 +96,7 @@
96 96  1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors.
97 97  
98 98  
101 +
99 99  == 2.3 Example to use for LoRaWAN network ==
100 100  
101 101  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -152,6 +152,7 @@
152 152  * Valid Sensor Value: Use FPORT=2
153 153  * Other control command: Use FPORT other than 2.
154 154  
158 +
155 155  === 2.4.1 Uplink FPORT~=5, Device Status ===
156 156  
157 157  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -357,6 +357,7 @@
357 357  * AT Command Connection: See [[FAQ>>||anchor="H7.FAQ"]].
358 358  * LoRaWAN Downlink instruction for different platforms:  [[Use Note for Server>>doc:Main.WebHome]](IoT LoRaWAN Server)
359 359  
364 +
360 360  There are two kinds of commands to configure WSC1-L, they are:
361 361  
362 362  * (% style="color:#4472c4" %)**General Commands**.
... ... @@ -366,6 +366,7 @@
366 366  * General system settings like: uplink interval.
367 367  * LoRaWAN protocol & radio related command.
368 368  
374 +
369 369  They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack((% style="color:red" %)Note~*~*)(%%). These commands can be found on the wiki:  [[End Device Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
370 370  
371 371  (% style="color:red" %)Note~*~*: Please check early user manual if you don’t have v1.8.0 firmware.
... ... @@ -397,15 +397,18 @@
397 397  
398 398  
399 399  
406 +
400 400  == 3.2 Set Emergency Mode ==
401 401  
402 402  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
403 403  
411 +
404 404  (% style="color:#037691" %)**AT Command:**
405 405  
406 -[[image:image-20220624142956-9.png]]
414 +|**Command Example**|**Function**|**Response**
415 +|AT+ALARMMOD=1|Enter emergency mode. Uplink every 1 minute|OK
416 +|AT+ALARMMOD=0|Exit emergency mode. Uplink base on TDC time|OK
407 407  
408 -
409 409  (% style="color:#037691" %)**Downlink Command:**
410 410  
411 411  * 0xE101     Same as: AT+ALARMMOD=1
... ... @@ -414,6 +414,7 @@
414 414  
415 415  
416 416  
426 +
417 417  == 3.3 Add or Delete RS485 Sensor ==
418 418  
419 419  Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors.
... ... @@ -420,31 +420,32 @@
420 420  
421 421  (% style="color:#037691" %)**AT Command: **
422 422  
423 -**AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout**
433 +AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout
424 424  
425 -* Type_Code range:  A1 ~~ A4
426 -* Query_Length:  RS485 Query frame length, Value cannot be greater than 10
427 -* Query_Command:  RS485 Query frame data to be sent to sensor, cannot be larger than 10 bytes
428 -* Read_Length:  RS485 response frame length supposed to receive. Max can receive
429 -* Valid_Data:  valid data from RS485 Response, Valid Data will be added to Payload and upload via LoRaWAN.
430 -* has_CRC:  RS485 Response crc check  (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0.
431 -* timeout:  RS485 receive timeout (uint:ms). Device will close receive window after timeout
435 +* Type_Code range: A1 ~~ A4
436 +* Query_Length: RS485 Query frame length, Value cannot be greater than 10
437 +* Query_Command: RS485 Query frame data to be sent to sensor, cannot be larger than 10 bytes
438 +* Read_Length: RS485 response frame length supposed to receive. Max can receive
439 +* Valid_Data: valid data from RS485 Response, Valid Data will be added to Payload and upload via LoRaWAN.
440 +* has_CRC: RS485 Response crc check  (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0.
441 +* timeout: RS485 receive timeout (uint:ms). Device will close receive window after timeout
432 432  
443 +Example:
433 433  
434 -**Example:**
435 -
436 436  User need to change external sensor use the type code as address code.
437 437  
438 438  With a 485 sensor, after correctly changing the address code to A1, the RS485 query frame is shown in the following table:
439 439  
440 -[[image:image-20220624143553-10.png]]
449 +|Address Code|Function Code|(% colspan="2" %)Start Register|(% colspan="2" %)Data Length|CRC Check Low|CRC Check High
450 +|0xA1|0x03|0x00|0x00|0x00|0x01|0x9C|0xAA
451 +| | | | | | | |
441 441  
442 -
443 443  The response frame of the sensor is as follows:
444 444  
445 -[[image:image-20220624143618-11.png]]
455 +|Address Code|Function Code|(% colspan="2" %)Data Length|(% colspan="2" %)Data|CRC Check Low|CRC Check High
456 +|0xA1|0x03|0x00|0x02|0x00|0x0A|0x7C|0xAD
457 +| | | | | | | |
446 446  
447 -
448 448  Then the following parameters should be:
449 449  
450 450  * Address_Code range: A1
... ... @@ -485,6 +485,7 @@
485 485  
486 486  
487 487  
499 +
488 488  == 3.4 RS485 Test Command ==
489 489  
490 490  (% style="color:#037691" %)**AT Command:**
... ... @@ -508,6 +508,7 @@
508 508  
509 509  
510 510  
523 +
511 511  == 3.5 RS485 response timeout ==
512 512  
513 513  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -533,6 +533,7 @@
533 533  
534 534  
535 535  
549 +
536 536  == 3.6 Set Sensor Type ==
537 537  
538 538  Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.
image-20220624142956-9.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -9.2 KB
Content
image-20220624143553-10.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -6.7 KB
Content
image-20220624143618-11.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -6.3 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0