Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/04/25 09:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -67,6 +67,7 @@ 67 67 * WSC1-L has an extra 1000mAh back up battery. So it can work even solar panel and storage battery Fails. 68 68 * Weather sensors won’t work if solar panel and storage battery fails. 69 69 70 + 70 70 (% style="color:red" %)** Notice 2:** 71 71 72 72 Due to shipment and importation limitation, user is better to purchase below parts locally: ... ... @@ -78,6 +78,7 @@ 78 78 * Cabinet. 79 79 80 80 82 + 81 81 == 2.2 How it works? == 82 82 83 83 ((( ... ... @@ -96,6 +96,7 @@ 96 96 1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors. 97 97 98 98 101 + 99 99 == 2.3 Example to use for LoRaWAN network == 100 100 101 101 This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure. ... ... @@ -152,6 +152,7 @@ 152 152 * Valid Sensor Value: Use FPORT=2 153 153 * Other control command: Use FPORT other than 2. 154 154 158 + 155 155 === 2.4.1 Uplink FPORT~=5, Device Status === 156 156 157 157 Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours ... ... @@ -357,6 +357,7 @@ 357 357 * AT Command Connection: See [[FAQ>>||anchor="H7.FAQ"]]. 358 358 * LoRaWAN Downlink instruction for different platforms: [[Use Note for Server>>doc:Main.WebHome]](IoT LoRaWAN Server) 359 359 364 + 360 360 There are two kinds of commands to configure WSC1-L, they are: 361 361 362 362 * (% style="color:#4472c4" %)**General Commands**. ... ... @@ -366,6 +366,7 @@ 366 366 * General system settings like: uplink interval. 367 367 * LoRaWAN protocol & radio related command. 368 368 374 + 369 369 They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack((% style="color:red" %)Note~*~*)(%%). These commands can be found on the wiki: [[End Device Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 370 370 371 371 (% style="color:red" %)Note~*~*: Please check early user manual if you don’t have v1.8.0 firmware. ... ... @@ -382,9 +382,20 @@ 382 382 383 383 (% style="color:#037691" %)**AT Command: AT+TDC** 384 384 385 -[[image:image-20220624142619-8.png]] 391 +|**Command Example**|**Function**|**Response** 392 +|AT+TDC?|Show current transmit Interval|((( 393 +30000 386 386 395 +OK 387 387 397 +the interval is 30000ms = 30s 398 +))) 399 +|AT+TDC=60000|Set Transmit Interval|((( 400 +OK 401 + 402 +Set transmit interval to 60000ms = 60 seconds 403 +))) 404 + 388 388 (% style="color:#037691" %)**Downlink Command: 0x01** 389 389 390 390 Format: Command Code (0x01) followed by 3 bytes time value. ... ... @@ -394,26 +394,22 @@ 394 394 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 395 395 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 396 396 397 - 398 - 399 - 400 400 == 3.2 Set Emergency Mode == 401 401 402 402 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. 403 403 418 + 404 404 (% style="color:#037691" %)**AT Command:** 405 405 406 -[[image:image-20220624142956-9.png]] 421 +|**Command Example**|**Function**|**Response** 422 +|AT+ALARMMOD=1|Enter emergency mode. Uplink every 1 minute|OK 423 +|AT+ALARMMOD=0|Exit emergency mode. Uplink base on TDC time|OK 407 407 408 - 409 409 (% style="color:#037691" %)**Downlink Command:** 410 410 411 411 * 0xE101 Same as: AT+ALARMMOD=1 412 412 * 0xE100 Same as: AT+ALARMMOD=0 413 413 414 - 415 - 416 - 417 417 == 3.3 Add or Delete RS485 Sensor == 418 418 419 419 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. ... ... @@ -420,31 +420,32 @@ 420 420 421 421 (% style="color:#037691" %)**AT Command: ** 422 422 423 - **AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout**436 +AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout 424 424 425 -* Type_Code range: 426 -* Query_Length: 427 -* Query_Command: 428 -* Read_Length: 429 -* Valid_Data: 430 -* has_CRC: 431 -* timeout: 438 +* Type_Code range: A1 ~~ A4 439 +* Query_Length: RS485 Query frame length, Value cannot be greater than 10 440 +* Query_Command: RS485 Query frame data to be sent to sensor, cannot be larger than 10 bytes 441 +* Read_Length: RS485 response frame length supposed to receive. Max can receive 442 +* Valid_Data: valid data from RS485 Response, Valid Data will be added to Payload and upload via LoRaWAN. 443 +* has_CRC: RS485 Response crc check (0: no verification required 1: verification required). If CRC=1 and CRC error, valid data will be set to 0. 444 +* timeout: RS485 receive timeout (uint:ms). Device will close receive window after timeout 432 432 446 +Example: 433 433 434 -**Example:** 435 - 436 436 User need to change external sensor use the type code as address code. 437 437 438 438 With a 485 sensor, after correctly changing the address code to A1, the RS485 query frame is shown in the following table: 439 439 440 -[[image:image-20220624143553-10.png]] 452 +|Address Code|Function Code|(% colspan="2" %)Start Register|(% colspan="2" %)Data Length|CRC Check Low|CRC Check High 453 +|0xA1|0x03|0x00|0x00|0x00|0x01|0x9C|0xAA 454 +| | | | | | | | 441 441 442 - 443 443 The response frame of the sensor is as follows: 444 444 445 -[[image:image-20220624143618-11.png]] 458 +|Address Code|Function Code|(% colspan="2" %)Data Length|(% colspan="2" %)Data|CRC Check Low|CRC Check High 459 +|0xA1|0x03|0x00|0x02|0x00|0x0A|0x7C|0xAD 460 +| | | | | | | | 446 446 447 - 448 448 Then the following parameters should be: 449 449 450 450 * Address_Code range: A1 ... ... @@ -482,9 +482,6 @@ 482 482 483 483 * 0xE5FF 484 484 485 - 486 - 487 - 488 488 == 3.4 RS485 Test Command == 489 489 490 490 (% style="color:#037691" %)**AT Command:** ... ... @@ -505,9 +505,6 @@ 505 505 506 506 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 507 507 508 - 509 - 510 - 511 511 == 3.5 RS485 response timeout == 512 512 513 513 Feature: Set or get extended time to receive 485 sensor data. ... ... @@ -530,9 +530,6 @@ 530 530 * Example 1: Downlink Payload: E0000005 ~/~/ Set Transmit Interval (DTR) = 5 seconds 531 531 * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds 532 532 533 - 534 - 535 - 536 536 == 3.6 Set Sensor Type == 537 537 538 538 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.
- image-20220624142956-9.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -9.2 KB - Content
- image-20220624143553-10.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -6.7 KB - Content
- image-20220624143618-11.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -6.3 KB - Content