Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/04/25 09:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -169,7 +169,7 @@ 169 169 User can also use downlink command(0x2301) to ask WSC1-L to resend this uplink 170 170 171 171 |**Size (bytes)**|**1**|**2**|**1**|**1**|**2**|**3** 172 -|**Value**|[[Sensor Model>> path:#Sensor_model]]|[[Firmware Version>>path:#Firmware_version]]|[[Frequency Band>>path:#Fre_Band]]|[[Sub-band>>path:#Sub_band]]|[[BAT>>path:#Battery]]|[[Weather Sensor Types>>path:#Sensor_types]]172 +|**Value**|[[Sensor Model>>||anchor="HSensorModel:"]]|[[Firmware Version>>||anchor="HFirmwareVersion:"]]|[[Frequency Band>>||anchor="HFrequencyBand:"]]|[[Sub-band>>||anchor="HSub-Band:"]]|[[BAT>>||anchor="HBAT:"]]|[[Weather Sensor Types>>||anchor="HWeatherSensorTypes:"]] 173 173 174 174 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image011.png]] 175 175 ... ... @@ -178,17 +178,17 @@ 178 178 179 179 180 180 181 -==== (% style="color:#037691" %)**Sensor Model** (%%):====181 +==== (% style="color:#037691" %)**Sensor Model:** ==== 182 182 183 183 For WSC1-L, this value is 0x0D. 184 184 185 185 186 -==== (% style="color:#037691" %)**Firmware Version** (%%):====186 +==== (% style="color:#037691" %)**Firmware Version:** ==== 187 187 188 188 0x0100, Means: v1.0.0 version. 189 189 190 190 191 -==== (% style="color:#037691" %)**Frequency Band** :(%%)====191 +==== (% style="color:#037691" %)**Frequency Band:** ==== 192 192 193 193 *0x01: EU868 194 194 ... ... @@ -211,12 +211,12 @@ 211 211 *0x0a: AS923-3 212 212 213 213 214 -==== (% style="color:#037691" %)**Sub-Band** (%%):====214 +==== (% style="color:#037691" %)**Sub-Band:** ==== 215 215 216 216 value 0x00 ~~ 0x08(only for CN470, AU915,US915. Others are0x00) 217 217 218 218 219 -==== (% style="color:#037691" %)**BAT** (%%):====219 +==== (% style="color:#037691" %)**BAT:** ==== 220 220 221 221 shows the battery voltage for WSC1-L MCU. 222 222 ... ... @@ -223,7 +223,7 @@ 223 223 Ex1: 0x0BD6/1000 = 3.03 V 224 224 225 225 226 -==== (% style="color:#037691" %)**Weather Sensor Types:** (%%)====226 +==== (% style="color:#037691" %)**Weather Sensor Types:** ==== 227 227 228 228 |Byte3|Byte2|Byte1 229 229 ... ... @@ -263,11 +263,9 @@ 263 263 264 264 265 265 266 -1. 267 -11. 268 -111. Uplink FPORT=2, Real time sensor value 266 +=== 2.4.2 Uplink FPORT=2, Real time sensor value === 269 269 270 -WSC1-L will send this uplink after Device Config uplink once join LoRaWAN network successfully. And it will periodically send this uplink. Default interval is 20 minutes and [[can be changed>> path:#Uplink_Interval]].268 +WSC1-L will send this uplink after Device Config uplink once join LoRaWAN network successfully. And it will periodically send this uplink. Default interval is 20 minutes and [[can be changed>>||anchor="H"]]. 271 271 272 272 Uplink uses FPORT=2 and every 20 minutes send one uplink by default. 273 273 ... ... @@ -276,11 +276,11 @@ 276 276 277 277 |Sensor Segment 1|Sensor Segment 2|……|Sensor Segment n 278 278 279 -**Uplink Payload**: 277 +**(% style="color:#4472C4" %) Uplink Payload**: 280 280 281 281 |Type Code|Length (Bytes)|Measured Value 282 282 283 -**Sensor Segment Define**: 281 +**(% style="color:#4472C4" %) Sensor Segment Define**: 284 284 285 285 286 286 ... ... @@ -390,9 +390,7 @@ 390 390 391 391 392 392 393 -1. 394 -11. 395 -111. Decoder in TTN V3 391 +=== 2.4.3 Decoder in TTN V3 === 396 396 397 397 In LoRaWAN platform, user only see HEX payload by default, user needs to use payload formatters to decode the payload to see human-readable value. 398 398 ... ... @@ -407,15 +407,14 @@ 407 407 408 408 409 409 410 -1. 411 -11. Show data on Application Server 406 +== 2.5 Show data on Application Server == 412 412 413 413 Application platform provides a human friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps: 414 414 415 415 416 -**Step 1**: Be sure that your device is programmed and properly connected to the LoRaWAN network. 411 +**(% style="color:blue" %)Step 1**(%%): Be sure that your device is programmed and properly connected to the LoRaWAN network. 417 417 418 -**Step 2**: Configure your Application to forward data to Datacake you will need to add integration. Go to TTN V3 Console ~-~-> Applications ~-~-> Integrations ~-~-> Add Integrations. 413 +**(% style="color:blue" %)Step 2**(%%): Configure your Application to forward data to Datacake you will need to add integration. Go to TTN V3 Console ~-~-> Applications ~-~-> Integrations ~-~-> Add Integrations. 419 419 420 420 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image014.png]] 421 421 ... ... @@ -433,13 +433,13 @@ 433 433 434 434 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image017.png]] 435 435 436 -* 437 437 438 -1. Configure WSC1-L via AT Command or LoRaWAN Downlink 439 439 433 += 3. Configure WSC1-L via AT Command or LoRaWAN Downlink = 434 + 440 440 Use can configure WSC1-L via AT Command or LoRaWAN Downlink. 441 441 442 -* AT Command Connection: See [[FAQ>> path:#AT_COMMAND]].437 +* AT Command Connection: See [[FAQ>>||anchor="H"]]. 443 443 * LoRaWAN Downlink instruction for different platforms: 444 444 445 445 [[http:~~/~~/wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server>>url:http://wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server]] ... ... @@ -447,7 +447,7 @@ 447 447 448 448 There are two kinds of commands to configure WSC1-L, they are: 449 449 450 -* **General Commands**. 445 +* **(% style="color:#4472C4" %)General Commands**. 451 451 452 452 These commands are to configure: 453 453 ... ... @@ -454,24 +454,23 @@ 454 454 * General system settings like: uplink interval. 455 455 * LoRaWAN protocol & radio related command. 456 456 457 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack(Note~*~*). These commands can be found on the wiki: 452 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack((% style="color:red" %)Note~*~*)(%%). These commands can be found on the wiki: 458 458 459 459 [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_Downlink_Command>>url:http://wiki.dragino.com/index.php?title=End_Device_Downlink_Command]] 460 460 461 -Note~*~*: Please check early user manual if you don’t have v1.8.0 firmware. 456 +(% style="color:red" %)Note~*~*: Please check early user manual if you don’t have v1.8.0 firmware. 462 462 463 463 464 -* **Commands special design for WSC1-L** 459 +* **(% style="color:#4472C4" %)Commands special design for WSC1-L** 465 465 466 466 These commands only valid for WSC1-L, as below: 467 467 468 468 469 -1. 470 -11. Set Transmit Interval Time 464 +== 3.1 Set Transmit Interval Time == 471 471 472 472 Feature: Change LoRaWAN End Node Transmit Interval. 473 473 474 -**AT Command: AT+TDC** 468 +**(% style="color:#037691" %)AT Command: AT+TDC** 475 475 476 476 |**Command Example**|**Function**|**Response** 477 477 |AT+TDC?|Show current transmit Interval|((( ... ... @@ -487,7 +487,7 @@ 487 487 Set transmit interval to 60000ms = 60 seconds 488 488 ))) 489 489 490 -**Downlink Command: 0x01** 484 +**(% style="color:#037691" %)Downlink Command: 0x01** 491 491 492 492 Format: Command Code (0x01) followed by 3 bytes time value. 493 493 ... ... @@ -498,30 +498,33 @@ 498 498 499 499 500 500 501 -1. 502 -11. Set Emergency Mode 503 503 496 + 497 +== 3.2 Set Emergency Mode == 498 + 504 504 Feature: In emergency mode, WSC1-L will uplink data every 1 minute. 505 505 506 506 507 -**AT Command:** 502 +**(% style="color:#037691" %)AT Command:** 508 508 509 509 |**Command Example**|**Function**|**Response** 510 510 |AT+ALARMMOD=1|Enter emergency mode. Uplink every 1 minute|OK 511 511 |AT+ALARMMOD=0|Exit emergency mode. Uplink base on TDC time|OK 512 512 513 -**Downlink Command:** 508 +**(% style="color:#037691" %)Downlink Command:** 514 514 515 515 * 0xE101 Same as: AT+ALARMMOD=1 516 516 * 0xE100 Same as: AT+ALARMMOD=0 517 517 518 518 519 -1. 520 -11. Add or Delete RS485 Sensor 521 521 515 + 516 + 517 +== 3.3 Add or Delete RS485 Sensor == 518 + 522 522 Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors. 523 523 524 -**AT Command: ** 521 +**(% style="color:#037691" %)AT Command: ** 525 525 526 526 AT+DYSENSOR=Type_Code, Query_Length, Query_Command , Read_Length , Valid_Data ,has_CRC,timeout 527 527 ... ... @@ -580,7 +580,7 @@ 580 580 AT+DYSENSOR ~-~-> List All 3^^rd^^ Party Sensor. Like below: 581 581 582 582 583 -**Downlink Command: ** 580 +**(% style="color:#037691" %)Downlink Command: ** 584 584 585 585 **delete custom sensor A1:** 586 586 ... ... @@ -591,11 +591,13 @@ 591 591 * 0xE5FF 592 592 593 593 594 -1. 595 -11. RS485 Test Command 596 596 597 -**AT Command:** 598 598 593 + 594 +== 3.4 RS485 Test Command == 595 + 596 +**(% style="color:#037691" %)AT Command:** 597 + 599 599 |**Command Example**|**Function**|**Response** 600 600 |AT+RSWRITE=xxxxxx|((( 601 601 Send command to 485 sensor ... ... @@ -608,18 +608,17 @@ 608 608 AT+RSWRITE=0103000001840A 609 609 610 610 611 -**Downlink Command:** 610 +**(% style="color:#037691" %)Downlink Command:** 612 612 613 613 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 614 614 615 615 616 616 617 -1. 618 -11. RS485 response timeout 616 +== 3.5 RS485 response timeout == 619 619 620 620 Feature: Set or get extended time to receive 485 sensor data. 621 621 622 -**AT Command:** 620 +**(% style="color:#037691" %)AT Command:** 623 623 624 624 |**Command Example**|**Function**|**Response** 625 625 |AT+DTR=1000|((( ... ... @@ -628,7 +628,7 @@ 628 628 Range : 0~~10000 629 629 )))|OK 630 630 631 -**Downlink Command:** 629 +**(% style="color:#037691" %)Downlink Command:** 632 632 633 633 Format: Command Code (0xE0) followed by 3 bytes time value. 634 634 ... ... @@ -639,12 +639,13 @@ 639 639 640 640 641 641 642 -1. 643 -11. Set Sensor Type 644 644 641 + 642 +== 3.6 Set Sensor Type == 643 + 645 645 Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values. 646 646 647 -See [[definition>> path:#Sensor_types]] for the sensor type.646 +See [[definition>>||anchor="H"]] for the sensor type. 648 648 649 649 650 650 |(% rowspan="2" %)Byte3|Bit23|Bit22|Bit21|Bit20|Bit19|Bit18|Bit17|Bit16 ... ... @@ -670,7 +670,7 @@ 670 670 Direction 671 671 )))|Wind Speed|BAT 672 672 673 -**AT Command:** 672 +**(% style="color:#037691" %)AT Command:** 674 674 675 675 |**Command Example**|**Function**|**Response** 676 676 |AT+STYPE=80221|Set sensor types|OK ... ... @@ -687,11 +687,11 @@ 687 687 So wsc1-L will upload the following data: Custom Sensor A1, Rain Gauge,CO2,BAT. 688 688 689 689 690 -**Downlink Command:** 689 +**(% style="color:#037691" %)Downlink Command:** 691 691 692 692 * 0xE400802212 Same as: AT+STYPE=80221 693 693 694 -Note: 693 +(% style="color:red" %)**Note:** 695 695 696 696 ~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned 697 697 ... ... @@ -699,21 +699,20 @@ 699 699 700 700 701 701 702 -1. Power consumption and battery 703 -11. Total Power Consumption 701 += 4. Power consumption and battery = 704 704 703 +== 4.1 Total Power Consumption == 704 + 705 705 Dragino Weather Station serial products include the main process unit ( WSC1-L ) and various sensors. The total power consumption equal total power of all above units. The power consumption for main process unit WSC1-L is 18ma @ 12v. and the power consumption of each sensor can be found on the Sensors chapter. 706 706 707 707 708 -1. 709 -11. Reduce power consumption 708 +== 4.2 Reduce power consumption == 710 710 711 711 The main process unit WSC1-L is set to LoRaWAN Class C by default. If user want to reduce the power consumption of this unit, user can set it to run in Class A. In Class A mode, WSC1-L will not be to get real-time downlink command from IoT Server. 712 712 713 713 714 714 715 -1. 716 -11. Battery 714 +== 4.3 Battery == 717 717 718 718 All sensors are only power by external power source. If external power source is off. All sensor won’t work. 719 719 ... ... @@ -722,13 +722,10 @@ 722 722 723 723 724 724 723 += 5. Main Process Unit WSC1-L = 725 725 725 +== 5.1 Features == 726 726 727 - 728 - 729 -1. Main Process Unit WSC1-L 730 -11. Features 731 - 732 732 * Wall Attachable. 733 733 * LoRaWAN v1.0.3 Class A protocol. 734 734 * RS485 / Modbus protocol ... ... @@ -743,27 +743,25 @@ 743 743 744 744 745 745 746 -1. 747 -11. Power Consumption 748 748 742 + 743 +== 5.2 Power Consumption == 744 + 749 749 WSC1-L (without external sensor): Idle: 4mA, Transmit: max 40mA 750 750 751 751 752 752 753 -1. 754 -11. Storage & Operation Temperature 749 +== 5.3 Storage & Operation Temperature == 755 755 756 756 -20°C to +60°C 757 757 758 758 759 -1. 760 -11. Pin Mapping 754 +== 5.4 Pin Mapping == 761 761 762 762 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image004.png]] 763 763 764 764 765 -1. 766 -11. Mechanical 759 +== 5.5 Mechanical == 767 767 768 768 Refer LSn50v2 enclosure drawing in: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/>>url:https://www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/]] 769 769 ... ... @@ -770,8 +770,7 @@ 770 770 771 771 772 772 773 -1. 774 -11. Connect to RS485 Sensors 766 +== 5.6 Connect to RS485 Sensors == 775 775 776 776 WSC1-L includes a RS485 converter PCB. Which help it easy to connect multiply RS485 sensors. Below is the photo for reference. 777 777