67 67  * WSC1-L has an extra 1000mAh back up battery. So it can work even solar panel and storage battery Fails.
68 68  * Weather sensors won’t work if solar panel and storage battery fails.
69 69  
70 +
70 70  (% style="color:red" %)** Notice 2:**
71 71  
72 72  Due to shipment and importation limitation, user is better to purchase below parts locally:
... ... @@ -152,6 +152,7 @@
152 152  * Valid Sensor Value: Use FPORT=2
153 153  * Other control command: Use FPORT other than 2.
154 154  
156 +
155 155  === 2.4.1 Uplink FPORT~=5, Device Status ===
156 156  
157 157  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -357,6 +357,7 @@
357 357  * AT Command Connection: See [[FAQ>>||anchor="H7.FAQ"]].
358 358  * LoRaWAN Downlink instruction for different platforms:  [[Use Note for Server>>doc:Main.WebHome]](IoT LoRaWAN Server)
359 359  
362 +
360 360  There are two kinds of commands to configure WSC1-L, they are:
361 361  
362 362  * (% style="color:#4472c4" %)**General Commands**.
... ... @@ -382,9 +382,20 @@
382 382  
383 383  (% style="color:#037691" %)**AT Command: AT+TDC**
384 384  
385 -[[image:image-20220624142619-8.png]]
388 +|**Command Example**|**Function**|**Response**
389 +|AT+TDC?|Show current transmit Interval|(((
390 +30000
386 386  
392 +OK
387 387  
394 +the interval is 30000ms = 30s
395 +)))
396 +|AT+TDC=60000|Set Transmit Interval|(((
397 +OK
398 +
399 +Set transmit interval to 60000ms = 60 seconds
400 +)))
401 +
388 388  (% style="color:#037691" %)**Downlink Command: 0x01**
389 389  
390 390  Format: Command Code (0x01) followed by 3 bytes time value.
... ... @@ -394,9 +394,6 @@
394 394  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
395 395  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
396 396  
397 -
398 -
399 -
400 400  == 3.2 Set Emergency Mode ==
401 401  
402 402  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
... ... @@ -413,9 +413,6 @@
413 413  * 0xE101     Same as: AT+ALARMMOD=1
414 414  * 0xE100     Same as: AT+ALARMMOD=0
415 415  
416 -
417 -
418 -
419 419  == 3.3 Add or Delete RS485 Sensor ==
420 420  
421 421  Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors.
... ... @@ -485,9 +485,6 @@
485 485  
486 486  * 0xE5FF  
487 487  
488 -
489 -
490 -
491 491  == 3.4 RS485 Test Command ==
492 492  
493 493  (% style="color:#037691" %)**AT Command:**
... ... @@ -508,9 +508,6 @@
508 508  
509 509  * 0xE20103000001840A     Same as: AT+RSWRITE=0103000001840A
510 510  
511 -
512 -
513 -
514 514  == 3.5 RS485 response timeout ==
515 515  
516 516  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -533,9 +533,6 @@
533 533  * Example 1: Downlink Payload: E0000005 ~/~/ Set Transmit Interval (DTR) = 5 seconds
534 534  * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds
535 535  
536 -
537 -
538 -
539 539  == 3.6 Set Sensor Type ==
540 540  
541 541  Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.