... ... @@ -388,9 +388,20 @@
388 388  
389 389  (% style="color:#037691" %)**AT Command: AT+TDC**
390 390  
391 -[[image:image-20220624142619-8.png]]
391 +|**Command Example**|**Function**|**Response**
392 +|AT+TDC?|Show current transmit Interval|(((
393 +30000
392 392  
395 +OK
393 393  
397 +the interval is 30000ms = 30s
398 +)))
399 +|AT+TDC=60000|Set Transmit Interval|(((
400 +OK
401 +
402 +Set transmit interval to 60000ms = 60 seconds
403 +)))
404 +
394 394  (% style="color:#037691" %)**Downlink Command: 0x01**
395 395  
396 396  Format: Command Code (0x01) followed by 3 bytes time value.
... ... @@ -400,10 +400,6 @@
400 400  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
401 401  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
402 402  
403 -
404 -
405 -
406 -
407 407  == 3.2 Set Emergency Mode ==
408 408  
409 409  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
... ... @@ -420,10 +420,6 @@
420 420  * 0xE101     Same as: AT+ALARMMOD=1
421 421  * 0xE100     Same as: AT+ALARMMOD=0
422 422  
423 -
424 -
425 -
426 -
427 427  == 3.3 Add or Delete RS485 Sensor ==
428 428  
429 429  Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors.
... ... @@ -493,10 +493,6 @@
493 493  
494 494  * 0xE5FF  
495 495  
496 -
497 -
498 -
499 -
500 500  == 3.4 RS485 Test Command ==
501 501  
502 502  (% style="color:#037691" %)**AT Command:**
... ... @@ -517,10 +517,6 @@
517 517  
518 518  * 0xE20103000001840A     Same as: AT+RSWRITE=0103000001840A
519 519  
520 -
521 -
522 -
523 -
524 524  == 3.5 RS485 response timeout ==
525 525  
526 526  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -543,10 +543,6 @@
543 543  * Example 1: Downlink Payload: E0000005 ~/~/ Set Transmit Interval (DTR) = 5 seconds
544 544  * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds
545 545  
546 -
547 -
548 -
549 -
550 550  == 3.6 Set Sensor Type ==
551 551  
552 552  Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved