From version < 28.1 >
edited by Xiaoling
on 2022/06/24 14:26
To version < 29.2 >
edited by Xiaoling
on 2022/06/24 14:30
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -67,7 +67,6 @@
67 67  * WSC1-L has an extra 1000mAh back up battery. So it can work even solar panel and storage battery Fails.
68 68  * Weather sensors won’t work if solar panel and storage battery fails.
69 69  
70 -
71 71  (% style="color:red" %)** Notice 2:**
72 72  
73 73  Due to shipment and importation limitation, user is better to purchase below parts locally:
... ... @@ -79,7 +79,6 @@
79 79  * Cabinet.
80 80  
81 81  
82 -
83 83  == 2.2 How it works? ==
84 84  
85 85  (((
... ... @@ -98,7 +98,6 @@
98 98  1. User can send a downlink command to WSC1-L to do a re-scan on the available sensors.
99 99  
100 100  
101 -
102 102  == 2.3 Example to use for LoRaWAN network ==
103 103  
104 104  This section shows an example for how to join the TTN V3 LoRaWAN IoT server. Usages with other LoRaWAN IoT servers are of similar procedure.
... ... @@ -155,7 +155,6 @@
155 155  * Valid Sensor Value: Use FPORT=2
156 156  * Other control command: Use FPORT other than 2.
157 157  
158 -
159 159  === 2.4.1 Uplink FPORT~=5, Device Status ===
160 160  
161 161  Uplink the device configures with FPORT=5. Once WSC1-L Joined the network, it will uplink this message to the server. After first uplink, WSC1-L will uplink Device Status every 12 hours
... ... @@ -361,7 +361,6 @@
361 361  * AT Command Connection: See [[FAQ>>||anchor="H7.FAQ"]].
362 362  * LoRaWAN Downlink instruction for different platforms:  [[Use Note for Server>>doc:Main.WebHome]](IoT LoRaWAN Server)
363 363  
364 -
365 365  There are two kinds of commands to configure WSC1-L, they are:
366 366  
367 367  * (% style="color:#4472c4" %)**General Commands**.
... ... @@ -371,7 +371,6 @@
371 371  * General system settings like: uplink interval.
372 372  * LoRaWAN protocol & radio related command.
373 373  
374 -
375 375  They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack((% style="color:red" %)Note~*~*)(%%). These commands can be found on the wiki:  [[End Device Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
376 376  
377 377  (% style="color:red" %)Note~*~*: Please check early user manual if you don’t have v1.8.0 firmware.
... ... @@ -388,20 +388,9 @@
388 388  
389 389  (% style="color:#037691" %)**AT Command: AT+TDC**
390 390  
391 -|**Command Example**|**Function**|**Response**
392 -|AT+TDC?|Show current transmit Interval|(((
393 -30000
385 +[[image:image-20220624142619-8.png]]
394 394  
395 -OK
396 396  
397 -the interval is 30000ms = 30s
398 -)))
399 -|AT+TDC=60000|Set Transmit Interval|(((
400 -OK
401 -
402 -Set transmit interval to 60000ms = 60 seconds
403 -)))
404 -
405 405  (% style="color:#037691" %)**Downlink Command: 0x01**
406 406  
407 407  Format: Command Code (0x01) followed by 3 bytes time value.
... ... @@ -411,22 +411,26 @@
411 411  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
412 412  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
413 413  
397 +
398 +
399 +
414 414  == 3.2 Set Emergency Mode ==
415 415  
416 416  Feature: In emergency mode, WSC1-L will uplink data every 1 minute.
417 417  
418 -
419 419  (% style="color:#037691" %)**AT Command:**
420 420  
421 -|**Command Example**|**Function**|**Response**
422 -|AT+ALARMMOD=1|Enter emergency mode. Uplink every 1 minute|OK
423 -|AT+ALARMMOD=0|Exit emergency mode. Uplink base on TDC time|OK
406 +[[image:image-20220624142956-9.png]]
424 424  
408 +
425 425  (% style="color:#037691" %)**Downlink Command:**
426 426  
427 427  * 0xE101     Same as: AT+ALARMMOD=1
428 428  * 0xE100     Same as: AT+ALARMMOD=0
429 429  
414 +
415 +
416 +
430 430  == 3.3 Add or Delete RS485 Sensor ==
431 431  
432 432  Feature: User can add or delete 3^^rd^^ party sensor as long they are RS485/Modbus interface,baud rate support 9600.Maximum can add 4 sensors.
... ... @@ -496,6 +496,9 @@
496 496  
497 497  * 0xE5FF  
498 498  
486 +
487 +
488 +
499 499  == 3.4 RS485 Test Command ==
500 500  
501 501  (% style="color:#037691" %)**AT Command:**
... ... @@ -516,6 +516,9 @@
516 516  
517 517  * 0xE20103000001840A     Same as: AT+RSWRITE=0103000001840A
518 518  
509 +
510 +
511 +
519 519  == 3.5 RS485 response timeout ==
520 520  
521 521  Feature: Set or get extended time to receive 485 sensor data.
... ... @@ -538,6 +538,9 @@
538 538  * Example 1: Downlink Payload: E0000005 ~/~/ Set Transmit Interval (DTR) = 5 seconds
539 539  * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds
540 540  
534 +
535 +
536 +
541 541  == 3.6 Set Sensor Type ==
542 542  
543 543  Feature: Set sensor in used. If there are 6 sensors, user can set to only send 5 sensors values.
image-20220624142956-9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +9.2 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0