1429 +== 8.3  The rain gauge keeps showing an incorrect value of 102.2 ==
1430 +
1431 +When the rain gauge keeps showing wrong values, it means that the device has exceeded its maximum range.
1432 +Customer need to use RS485-USB to reset it
1433 +
1434 +Wiring method:
1435 +RS485-USB A<~-~-~-~-~-~-->rain gauge RS485A
1436 +RS485-USB B<~-~-~-~-~-~-->rain gauge RS485B
1437 +
1438 +
1439 +Use the reset command:
1440 +
1441 +06 06 00 37 00 03 79 B2
1442 +
1443 +[[image:image-20250219164620-1.png]]
1444 +
1445 +
1446 +
1447 +
1448 +