Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Mengting Qiu on 2025/06/10 18:53
From version 118.1
edited by Edwin Chen
on 2024/05/06 10:27
on 2024/05/06 10:27
Change comment:
There is no comment for this version
To version 125.2
edited by Mengting Qiu
on 2025/03/18 17:00
on 2025/03/18 17:00
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.ting - Content
-
... ... @@ -34,7 +34,7 @@ 34 34 ))) 35 35 36 36 ((( 37 -Main process device WSC1-L is an outdoor LoRaWAN RS485 end node. It is powered by external (% style="color:blue" %)**12v solar power**(%%) and have a (% style="color:blue" %)**built-in li-on backup battery**(%%). WSC1-L reads value from various sensors and upload these sensor data to IoT server via LoRaWAN wireless protocol.37 +Main process device WSC1-L is an outdoor LoRaWAN RS485 end node. It is powered by external (% style="color:blue" %)**12v solar power**(%%) and have a (% style="color:blue" %)**built-in Li-ion backup battery**(%%). WSC1-L reads value from various sensors and upload these sensor data to IoT server via LoRaWAN wireless protocol. 38 38 ))) 39 39 40 40 ((( ... ... @@ -131,17 +131,17 @@ 131 131 132 132 [[image:1656042662694-311.png]] 133 133 134 -[[image: 1656042673910-429.png]]134 +[[image:image-20250122085806-2.png||height="369" width="1010"]] 135 135 136 136 137 137 **Choose Manually to add WSC1-L** 138 138 139 -[[image: 1656042695755-103.png]]139 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LTC2-LB--LoRaWAN_Temperature_Transmitter_User_Manual/WebHome/image-20240907112136-6.png?width=697&height=687&rev=1.1||alt="image-20240907112136-6.png"]] 140 140 141 141 142 -**Add APPKEY and DEV EUI**142 +**Add Keys** 143 143 144 -[[image: 1656042723199-746.png]]144 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LTC2-LB--LoRaWAN_Temperature_Transmitter_User_Manual/WebHome/image-20240907112427-7.png?rev=1.1||alt="image-20240907112427-7.png"]] 145 145 146 146 147 147 ((( ... ... @@ -651,7 +651,6 @@ 651 651 652 652 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 653 653 654 - 655 655 == 3.5 RS485 response timeout == 656 656 657 657 ... ... @@ -739,17 +739,17 @@ 739 739 740 740 (% style="color:#037691" %)**AT Command:** 741 741 742 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width: 611px" %)743 -|=(% style="width: 2 72px; background-color: rgb(79, 129, 189); color: white;" %)**Command Example**|=(% style="width:114px; background-color: rgb(79, 129, 189); color: white;" %)**Function**|=(% style="width:264px; background-color: rgb(79, 129, 189); color: white;" %)**Response**744 -|(% style="width:2 72px" %)(((745 -AT+RAINFALLSWITCH=10(Value: 746 -)))|(% style="width: 114px" %)(((741 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 742 +|=(% style="width: 230px; background-color: rgb(79, 129, 189); color: white;" %)**Command Example**|=(% style="width: 232px; background-color: rgb(79, 129, 189); color: white;" %)**Function**|=(% style="width: 48px; background-color: rgb(79, 129, 189); color: white;" %)**Response** 743 +|(% style="width:240px" %)((( 744 +AT+RAINFALLSWITCH=10(Value:3,4,5,6,8,10) 745 +)))|(% style="width:232px" %)((( 747 747 Set the registers read by the rain gauge 748 -)))|(% style="width: 264px" %)OK747 +)))|(% style="width:38px" %)OK 749 749 750 750 (% style="color:#037691" %)**Downlink Command:** 751 751 752 -* 0x 1703 Same as: AT+RAINFALLSWITCH=3751 +* 0xE703 Same as: AT+RAINFALLSWITCH=3 753 753 754 754 Value Definition: 755 755 ... ... @@ -760,6 +760,36 @@ 760 760 * **8**: 24-hour minimum rainfall:0.0mm 761 761 * **10**: Rainfall in 24 hours: 8.0mm (Rainfall in the last 24 hours) 762 762 762 + 763 +== 3.8 Set the MSP mode(Since firmware V1.3.1) == 764 + 765 + 766 +(% style="color:red" %)**Note: This feature is available for WSS-02.** 767 + 768 +This function is used for the continuous collection of wind speed. 769 + 770 +When MSP mode is turned on (AT+MSP=1), WSC1-L will collect real-time wind speed **every 5 seconds**. Then it will judge the maximum wind speed in this period according to the wind speed collected in TDC time, and calculate the average wind speed according to the wind speed data collected in TDC time and the number of data groups. 771 + 772 +(% style="color:#037691" %)**AT Command: AT+MSP** 773 + 774 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 775 +|=(% style="width: 158px; background-color: rgb(79, 129, 189); color: white;" %)**Command Example**|=(% style="width: 214px; background-color: rgb(79, 129, 189); color: white;" %)**Function**|=(% style="width: 136px; background-color: rgb(79, 129, 189); color: white;" %)**Response** 776 +|(% style="width:158px" %)((( 777 +AT+MSP=? 778 +)))|(% style="width:214px" %)Query whether MSP mode is on|(% style="width:136px" %)((( 779 +0(default) 780 + 781 +OK 782 +))) 783 +|(% style="width:158px" %)AT+MSP=0|(% style="width:214px" %)Disable the MSP mode|(% style="width:136px" %)OK 784 +|(% style="width:158px" %)AT+MSP=1|(% style="width:214px" %)Enable the MSP mode|(% style="width:136px" %)OK 785 + 786 +(% style="color:#037691" %)**Downlink Command: 0X34** 787 + 788 +* Downlink payload: 34 00 ~/~/ Equal to AT+MSP=0 789 +* Downlink payload: 34 01 ~/~/ Equal to AT+MSP=1 790 + 791 + 763 763 = 4. Power consumption and battery = 764 764 765 765 == 4.1 Total Power Consumption == ... ... @@ -1209,7 +1209,6 @@ 1209 1209 1210 1210 [[image:1656057199955-514.png]] 1211 1211 1212 - 1213 1213 [[image:1656057212438-475.png]] 1214 1214 1215 1215 ... ... @@ -1269,10 +1269,8 @@ 1269 1269 1270 1270 Do not power on while connect the cables. Double check the wiring before power on. 1271 1271 1272 - 1273 1273 [[image:1656057369259-804.png]] 1274 1274 1275 - 1276 1276 [[image:1656057377943-564.png]] 1277 1277 1278 1278 ... ... @@ -1335,10 +1335,8 @@ 1335 1335 1336 1336 Do not power on while connect the cables. Double check the wiring before power on. 1337 1337 1338 - 1339 1339 [[image:1656057557191-895.png]] 1340 1340 1341 - 1342 1342 [[image:1656057565783-251.png]] 1343 1343 1344 1344 ... ... @@ -1391,22 +1391,23 @@ 1391 1391 1392 1392 Users can run the AT+RAINFALLSWITCH command to query the data of the rain gauge. 1393 1393 1394 -AT+RAINFALLSWITCH=10(Range: 3 ,4,5,6,8,10)1418 +AT+RAINFALLSWITCH=10(Range: 3,4,5,6,8,10) 1395 1395 1396 -**Rainfall query value :**1420 +**Rainfall query value:** 1397 1397 1398 1398 3:The total rainfall after the sensor is powered on (for example Total rainfall: 166.5mm) 1399 1399 1400 1400 4:Current Hourly rainfall: etc 0.2mm 1401 1401 1402 -5:Rainfall in last hour:etc 0.2mm 1426 +5:Rainfall in last hour: etc 0.2mm 1403 1403 1404 -6:24-hour maximum rainfall etc 10.0mm 1428 +6:24-hour maximum rainfall: etc 10.0mm 1405 1405 1406 -8:24-hour minimum rainfall:etc 0.0mm 1430 +8:24-hour minimum rainfall: etc 0.0mm 1407 1407 1408 -10:Rainfall in 24 hours: 8.0mm (Rainfall in the last 24 hours)1432 +10:Rainfall in 24 hours: 8.0mm (Rainfall in the last 24 hours) 1409 1409 1434 + 1410 1410 = 8. Trouble Shooting = 1411 1411 1412 1412 == 8.1 AT Command input doesn't work == ... ... @@ -1417,17 +1417,40 @@ 1417 1417 ))) 1418 1418 1419 1419 1420 -== 8.2 Possible reasons why the device is unresponsive :==1445 +== 8.2 Possible reasons why the device is unresponsive: == 1421 1421 1447 + 1422 1422 ~1. Check whether the battery voltage is lower than 2.8V 1423 1423 2. Check whether the jumper of the device is correctly connected 1424 1424 1425 1425 [[image:image-20240330173709-1.png]] 1426 -3. Check whether the switch here of the device is at the ISP(The switch can operate normally only when it is in RUN) 1427 1427 1428 1428 1454 +3. Check whether the switch here of the device is at the ISP(The switch can operate normally only when it is in RUN) 1455 + 1429 1429 [[image:image-20240330173724-2.png]] 1430 1430 1458 + 1459 +== 8.3 The rain gauge keeps showing an incorrect value of 102.2 == 1460 + 1461 +When the rain gauge keeps showing wrong values, it means that the device has exceeded its maximum range. 1462 +Customer need to use RS485-USB to reset it 1463 + 1464 +Wiring method: 1465 +RS485-USB A<~-~-~-~-~-~-->rain gauge RS485A 1466 +RS485-USB B<~-~-~-~-~-~-->rain gauge RS485B 1467 + 1468 + 1469 +Use the reset command: 1470 + 1471 +06 06 00 37 00 03 79 B2 1472 + 1473 +[[image:image-20250219164620-1.png]] 1474 + 1475 + 1476 + 1477 + 1478 + 1431 1431 = 9. Order Info = 1432 1432 1433 1433 == 9.1 Main Process Unit ==
- image-20250122085744-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +86.9 KB - Content
- image-20250122085806-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +109.8 KB - Content
- image-20250219164620-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.1 KB - Content