36 36  (((
37 -Main process device WSC1-L is an outdoor LoRaWAN RS485 end node. It is powered by external (% style="color:blue" %)**12v solar power**(%%) and have a (% style="color:blue" %)**built-in li-on backup battery**(%%). WSC1-L reads value from various sensors and upload these sensor data to IoT server via LoRaWAN wireless protocol.
37 +Main process device WSC1-L is an outdoor LoRaWAN RS485 end node. It is powered by external (% style="color:blue" %)**12v solar power**(%%) and have a (% style="color:blue" %)**built-in Li-ion backup battery**(%%). WSC1-L reads value from various sensors and upload these sensor data to IoT server via LoRaWAN wireless protocol.
38 38  )))
39 39  
40 40  (((
... ... @@ -64,7 +64,6 @@
64 64  
65 65  WSC1-L is shipped with a RS485 converter board, for the easy connection to different sensors and WSC1-L. Below is a connection photo:
66 66  
67 -
68 68  [[image:1656042136605-251.png]]
69 69  
70 70  
... ... @@ -103,8 +103,6 @@
103 103  1. WSC1-L will auto scan available weather sensors when power on or reboot.
104 104  1. User can send a [[downlink command>>||anchor="H3.ConfigureWSC1-LviaATCommandorLoRaWANDownlink"]] to WSC1-L to do a re-scan on the available sensors.
105 105  
106 -
107 -
108 108  == 2.3 Example to use for LoRaWAN network ==
109 109  
110 110  
... ... @@ -130,25 +130,47 @@
130 130  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSE01-LoRaWAN%20Soil%20Moisture%20%26%20EC%20Sensor%20User%20Manual/WebHome/image-20220606163915-7.png?rev=1.1||alt="image-20220606163915-7.png"]]
131 131  
132 132  
133 -**Add APP EUI in the application.**
130 +**Create the application.**
134 134  
135 -[[image:1656042662694-311.png]]
132 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SAC01L_LoRaWAN_Temperature%26Humidity_Sensor_User_Manual/WebHome/image-20250423093843-1.png?width=756&height=264&rev=1.1||alt="image-20250423093843-1.png"]]
136 136  
137 -[[image:1656042673910-429.png]]
134 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LTC2-LB--LoRaWAN_Temperature_Transmitter_User_Manual/WebHome/image-20240907111305-2.png?width=1000&height=572&rev=1.1||alt="image-20240907111305-2.png"]]
138 138  
139 139  
140 -**Choose Manually to add WSC1-L**
137 +**Add devices to the created Application.**
141 141  
142 -[[image:1656042695755-103.png]]
139 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LTC2-LB--LoRaWAN_Temperature_Transmitter_User_Manual/WebHome/image-20240907111659-3.png?width=977&height=185&rev=1.1||alt="image-20240907111659-3.png"]]
143 143  
141 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LTC2-LB--LoRaWAN_Temperature_Transmitter_User_Manual/WebHome/image-20240907111820-5.png?width=975&height=377&rev=1.1||alt="image-20240907111820-5.png"]]
144 144  
145 -**Add APP KEY and DEV EUI**
146 146  
147 -[[image:1656042723199-746.png]]
144 +**Enter end device specifics manually.**
148 148  
146 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LTC2-LB--LoRaWAN_Temperature_Transmitter_User_Manual/WebHome/image-20240907112136-6.png?width=697&height=687&rev=1.1||alt="image-20240907112136-6.png"]]
149 149  
148 +
149 +**Add DevEUI and AppKey.**
150 +
151 +**Customize a platform ID for the device.**
152 +
153 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LTC2-LB--LoRaWAN_Temperature_Transmitter_User_Manual/WebHome/image-20240907112427-7.png?rev=1.1||alt="image-20240907112427-7.png"]]
154 +
155 +
156 +(% style="color:blue" %)**Step 2**(%%): Add decoder.
157 +
158 +In TTN, user can add a custom payload so it shows friendly reading.
159 +
160 +Click this link to get the decoder: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder/tree/main/Weather%20Station>>https://github.com/dragino/dragino-end-node-decoder/tree/main/Weather%20Station]]
161 +
162 +Below is TTN screen shot:
163 +
164 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS25-LBLDS25-LS--LoRaWAN_LiDAR_Distance_Auto-Clean_Sensor_User_Manual/WebHome/image-20241009140556-1.png?width=1184&height=488&rev=1.1||alt="image-20241009140556-1.png" height="488" width="1184"]]
165 +
166 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS25-LBLDS25-LS--LoRaWAN_LiDAR_Distance_Auto-Clean_Sensor_User_Manual/WebHome/image-20241009140603-2.png?width=1168&height=562&rev=1.1||alt="image-20241009140603-2.png" height="562" width="1168"]]
167 +
168 +
150 150  (((
151 -(% style="color:blue" %)**Step 2**(%%): Power on WSC1-L, it will start to join TTN server. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel.
170 +(% style="color:blue" %)**Step 3**(%%): Power on WSC1-L, it will start to join TTN server. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel.
152 152  )))
153 153  
154 154  [[image:1656042745346-283.png]]
... ... @@ -271,6 +271,8 @@
271 271  === 2.4.2 Uplink FPORT~=2, Real time sensor value ===
272 272  
273 273  
293 +==== 2.4.2.1 paylaod before firmware V1.3.1(including v1.3.1) ====
294 +
274 274  (((
275 275  WSC1-L will send this uplink after Device Config uplink once join LoRaWAN network successfully. And it will periodically send this uplink. Default interval is 20 minutes and [[can be changed>>||anchor="H3.1SetTransmitIntervalTime"]].
276 276  )))
... ... @@ -409,6 +409,114 @@
409 409   Uplink 2:  [[image:image-20220624141100-7.png]]
410 410  
411 411  
433 +
434 +==== 2.4.2.2 paylaod since firmware V1.3.1 ====
435 +
436 +
437 +(% style="color:red" %)**Note: Since firmware V1.3.1, [[MSP mode>>||anchor="H3.8SettheMSPmode28SincefirmwareV1.3.129"]] has been added for WSS-02. Thus the wind speed paylaod length increases(Add 4 bytes for maximum wind speed and average wind speed).**
438 +
439 +(((
440 +The upload length is dynamic, depends on what type of weather sensors are connected. The uplink payload is combined with sensor segments. As below:
441 +)))
442 +
443 +(% style="color:#4472c4" %)** Uplink Payload**:
444 +
445 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:464px" %)
446 +|(% style="width:140px" %)Sensor Segment 1|(% style="width:139px" %)Sensor Segment 2|(% style="width:42px" %)……|(% style="width:140px" %)Sensor Segment n
447 +
448 +(% style="color:#4472c4" %)** Sensor Segment Define**:
449 +
450 +(% border="1" cellspacing="10" style="background-color:#f2f2f2; width:330px" %)
451 +|(% style="width:89px" %)Type Code|(% style="width:114px" %)Length (Bytes)|(% style="width:124px" %)Measured Value
452 +
453 +(% style="color:#4472c4" %)**Sensor Type Table:**
454 +
455 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
456 +|(% style="background-color:#4f81bd; color:white; width:80px" %)**Sensor Type**|(% style="background-color:#4f81bd; color:white; width:65px" %)**Type Code**|(% style="background-color:#4f81bd; color:white; width:97px" %)**Range**|(% style="background-color:#4f81bd; color:white; width:78px" %)**Length( Bytes)**|(% style="background-color:#4f81bd; color:white; width:190px" %)**Example**
457 +|(% style="width:103px" %)Wind Speed|(% style="width:91px" %)0x01|(% style="width:158px" %)(((
458 +①Speed: 0 ~~ 60m/s
459 +
460 +②(% style="color:#4472c4" %)**Maximum wind speed: **(%%)0 ~~ 60m/s
461 +
462 +③(% style="color:#4472c4" %)**Average wind speed:**(%%) 0 ~~ 60m/s
463 +④Level: 0 ~~ 17
464 +)))|(% style="width:122px" %)0x07 |(% style="width:904px" %)(((
465 +(((
466 +①0x0015/10=2.1m/s (0x02FE: No Sensor, 0x02EE: Value Error)
467 +
468 +②0x0024/10=3.6m/s
469 +
470 +③0x000E/10=1.4m/s
471 +)))
472 +
473 +(((
474 +④0x02=2 (0x14: No Sensor, 0x15: Value Error)
475 +)))
476 +)))
477 +|(% style="width:103px" %)Wind Direction|(% style="width:91px" %)0x02|(% style="width:158px" %)(((
478 +Angel: 0 ~~ 360°
479 +Direction: 16 positions
480 +)))|(% style="width:122px" %)0x03|(% style="width:904px" %)(((
481 +(((
482 +0x02C9/10=66.6°(0x0EFE: No Sensor,0x0EFF: Value Error)
483 +)))
484 +
485 +(((
486 +0X03=3(ENE) (0x14: No Sensor,0x15: Value Error)
487 +)))
488 +)))
489 +|(% style="width:103px" %)Illumination|(% style="width:91px" %)0x03|(% style="width:158px" %)0~200000kLux|(% style="width:122px" %)0x02|(% style="width:904px" %)(((
490 +0x04D2*10=12340kLux (0x4EFE: No Sensor,0x4EFF: Value Error)
491 +)))
492 +|(% style="width:103px" %)Rain / Snow|(% style="width:91px" %)0x04|(% style="width:158px" %)0A: No, 01 Yes.|(% style="width:122px" %)0x01|(% style="width:904px" %)(((
493 +(((
494 +0x00 (00) No Rain or snow detected
495 +)))
496 +
497 +(((
498 +(0x02: No Sensor,0x03: Value Error)
499 +)))
500 +)))
501 +|(% style="width:103px" %)CO2|(% style="width:91px" %)0x05|(% style="width:158px" %)0~5000ppm|(% style="width:122px" %)0x02|(% style="width:904px" %)(((
502 +0x0378=888ppm (0x14FE: No Sensor,0x14FF: Value Error)
503 +)))
504 +|(% style="width:103px" %)Temperature|(% style="width:91px" %)0x06|(% style="width:158px" %)-30℃~70℃|(% style="width:122px" %)0x02|(% style="width:904px" %)(((
505 +0xFFDD/10=-3.5℃ (0x02FE: No Sensor,0x02FF: Value Error)
506 +)))
507 +|(% style="width:103px" %)Humidity|(% style="width:91px" %)0x07|(% style="width:158px" %)0~100%RH|(% style="width:122px" %)0x02|(% style="width:904px" %)(((
508 +0x0164/10=35.6%RH (0x03FE: No Sensor,0x03FF: Value Error)
509 +)))
510 +|(% style="width:103px" %)Pressure|(% style="width:91px" %)0x08|(% style="width:158px" %)10~1100hPa|(% style="width:122px" %)0x02|(% style="width:904px" %)(((
511 +0x2748/10=1005.6hPa    (0x00: No Sensor,0x01: Value Error)
512 +)))
513 +|(% style="width:103px" %)Rain Gauge|(% style="width:91px" %)0x09|(% style="width:158px" %)(((
514 +0mm~100mm(Rainfall in the last 24 hours)
515 +)))|(% style="width:122px" %)0x02|(% style="width:904px" %)(((
516 +(((
517 +0x0050/10=8mm (Rainfall within the 24 hours:8.0mm)
518 +)))
519 +
520 +(((
521 +(0x03FE: No Sensor,0x03FF: Value Error)
522 +)))
523 +)))
524 +|(% style="width:103px" %)PM2.5|(% style="width:91px" %)0x0A|(% style="width:158px" %)0~1000μg/m^^3^^|(% style="width:122px" %)0x02|(% style="width:904px" %)(((
525 +0x0023=35μg/m^^3  ^^(0x03FE: No Sensor,0x03FF: Value Error)
526 +)))
527 +|(% style="width:103px" %)PM10|(% style="width:91px" %)0x0B|(% style="width:158px" %)0~1000μg/m^^3^^|(% style="width:122px" %)0x02|(% style="width:904px" %)(((
528 +0x002D=45μg/m^^3  ^^(0x03FE: No Sensor,0x03FF: Value Error)
529 +)))
530 +|(% style="width:103px" %)PAR|(% style="width:91px" %)0x0C|(% style="width:158px" %)(((
531 +0~2500μmol/m^^2^^•s
532 +)))|(% style="width:122px" %)0x02|(% style="width:904px" %)(((
533 +0x00B3=179μmol/m^^2^^•s (0x09FE: No Sensor,0x09FF: Value Error)
534 +)))
535 +|(% style="width:103px" %)(((
536 +Total Solar Radiation
537 +)))|(% style="width:91px" %)0x0D|(% style="width:158px" %)0~2000W/m^^2^^|(% style="width:122px" %)0x02|(% style="width:904px" %)(((
538 +0x0073/10=11.5W/m^^2^^(0x4EFE: No Sensor,0x4EFF: Value Error)
539 +)))
540 +
412 412  === 2.4.3 Decoder in TTN V3 ===
413 413  
414 414  
... ... @@ -647,7 +647,9 @@
647 647  
648 648  AT+RSWRITE=0103000001840A
649 649  
779 +If there is output from sensor, The console will show the output data
650 650  
781 +
651 651  (% style="color:#037691" %)**Downlink Command:**
652 652  
653 653  * 0xE20103000001840A     Same as: AT+RSWRITE=0103000001840A
... ... @@ -739,31 +739,55 @@
739 739  
740 740  (% style="color:#037691" %)**AT Command:**
741 741  
742 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:433px" %)
743 -|=(% style="width: 172px; background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 175px; background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 86px;background-color:#4F81BD;color:white" %)**Response**
744 -|(% style="width:161px" %)(((
745 -AT+RAINFALLSWITCH=10(Range: 3,4,5,6,8,10)
746 -)))|(% style="width:184px" %)(((
873 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
874 +|=(% style="width: 230px; background-color: rgb(79, 129, 189); color: white;" %)**Command Example**|=(% style="width: 232px; background-color: rgb(79, 129, 189); color: white;" %)**Function**|=(% style="width: 48px; background-color: rgb(79, 129, 189); color: white;" %)**Response**
875 +|(% style="width:240px" %)(((
876 +AT+RAINFALLSWITCH=10(Value:3,4,5,6,8,10)
877 +)))|(% style="width:232px" %)(((
747 747  Set the registers read by the rain gauge
748 -)))|(% style="width:85px" %)OK
879 +)))|(% style="width:38px" %)OK
749 749  
750 750  (% style="color:#037691" %)**Downlink Command:**
751 751  
752 -* 0x1703  Same as: AT+RAINFALLSWITCH=3
883 +* 0xE703  Same as: AT+RAINFALLSWITCH=3
753 753  
754 -3: The total rainfall after the sensor is powered on  (for example  Total rainfall: 166.5mm)
885 +Value Definition:
755 755  
756 -4: Hourly rainfall: 0.2mm
887 +* **3**: The total rainfall after the sensor is powered on  (for example  Total rainfall: 166.5mm)
888 +* **4**: Hourly rainfall: 0.2mm
889 +* **5**: Rainfall in last hour: 0.2mm
890 +* **6**: 24-hour maximum rainfall 10.0mm
891 +* **8**: 24-hour minimum rainfall:0.0mm
892 +* **10**: Rainfall in 24 hours: 8.0mm (Rainfall in the last 24 hours)
757 757  
758 -5: Rainfall in last hour: 0.2mm
894 +== 3.8 Set the MSP mode(Since firmware V1.3.1) ==
759 759  
760 -6: 24-hour maximum rainfall 10.0mm
761 761  
762 -8: 24-hour minimum rainfall:0.0mm
897 +(% style="color:red" %)**Note: This feature is available for WSS-02.**
763 763  
764 -10: Rainfall in 24 hours: 8.0mm (Rainfall in the last 24 hours)
899 +This function is used for the continuous collection of wind speed.
765 765  
901 +When MSP mode is turned on (AT+MSP=1), WSC1-L will collect real-time wind speed **every 5 seconds**. Then it will judge the maximum wind speed in this period according to the wind speed collected in TDC time, and calculate the average wind speed according to the wind speed data collected in TDC time and the number of data groups.
766 766  
903 +(% style="color:#037691" %)**AT Command: AT+MSP**
904 +
905 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
906 +|=(% style="width: 158px; background-color: rgb(79, 129, 189); color: white;" %)**Command Example**|=(% style="width: 214px; background-color: rgb(79, 129, 189); color: white;" %)**Function**|=(% style="width: 136px; background-color: rgb(79, 129, 189); color: white;" %)**Response**
907 +|(% style="width:158px" %)(((
908 +AT+MSP=?
909 +)))|(% style="width:214px" %)Query whether MSP mode is on|(% style="width:136px" %)(((
910 +0(default)
911 +
912 +OK
913 +)))
914 +|(% style="width:158px" %)AT+MSP=0|(% style="width:214px" %)Disable the MSP mode|(% style="width:136px" %)OK
915 +|(% style="width:158px" %)AT+MSP=1|(% style="width:214px" %)Enable the MSP mode|(% style="width:136px" %)OK
916 +
917 +(% style="color:#037691" %)**Downlink Command: 0X34**
918 +
919 +* Downlink payload: 34 00  ~/~/ Equal to AT+MSP=0
920 +* Downlink payload: 34 01  ~/~/ Equal to AT+MSP=1
921 +
767 767  = 4. Power consumption and battery =
768 768  
769 769  == 4.1 Total Power Consumption ==
... ... @@ -980,7 +980,7 @@
980 980  * Interface: RS485
981 981  * Working Temperature: -30℃ ~~ 70℃
982 982  * Working Humidity: <100% (no dewing)
983 -* Power Consumption: 13mA ~~ 12v.
1138 +* Power Consumption: 13mA @12v.
984 984  * Cable Length: 2 meters
985 985  
986 986  === 6.2.3 Dimension ===
... ... @@ -1075,7 +1075,6 @@
1075 1075  
1076 1076  Do not power on while connect the cables. Double check the wiring before power on.
1077 1077  
1078 -
1079 1079  [[image:1656056751153-304.png]]
1080 1080  
1081 1081  
... ... @@ -1181,7 +1181,7 @@
1181 1181  * Humidity Sensor Spec:
1182 1182  ** Range: 0 ~~ 100% RH
1183 1183  ** resolution 0.1 %RH
1184 -** Accuracy: 3% RH
1338 +** Accuracy: ±3% RH
1185 1185  * Pressure Sensor Spec:
1186 1186  ** Range: 10 ~~ 1100hPa
1187 1187  ** Resolution: 0.1hPa
... ... @@ -1213,7 +1213,6 @@
1213 1213  
1214 1214  [[image:1656057199955-514.png]]
1215 1215  
1216 -
1217 1217  [[image:1656057212438-475.png]]
1218 1218  
1219 1219  
... ... @@ -1273,10 +1273,8 @@
1273 1273  
1274 1274  Do not power on while connect the cables. Double check the wiring before power on.
1275 1275  
1276 -
1277 1277  [[image:1656057369259-804.png]]
1278 1278  
1279 -
1280 1280  [[image:1656057377943-564.png]]
1281 1281  
1282 1282  
... ... @@ -1339,10 +1339,8 @@
1339 1339  
1340 1340  Do not power on while connect the cables. Double check the wiring before power on.
1341 1341  
1342 -
1343 1343  [[image:1656057557191-895.png]]
1344 1344  
1345 -
1346 1346  [[image:1656057565783-251.png]]
1347 1347  
1348 1348  
... ... @@ -1395,22 +1395,23 @@
1395 1395  
1396 1396  Users can run the AT+RAINFALLSWITCH command to query the data of the rain gauge.
1397 1397  
1398 -AT+RAINFALLSWITCH=10(Range: 3456810
1547 +AT+RAINFALLSWITCH=10(Range: 3,4,5,6,8,10)
1399 1399  
1400 -**Rainfall query value**
1549 +**Rainfall query value:**
1401 1401  
1402 1402  3:The total rainfall after the sensor is powered on  (for example  Total rainfall: 166.5mm)
1403 1403  
1404 1404  4:Current Hourly rainfall: etc 0.2mm
1405 1405  
1406 -5:Rainfall in last hour:etc 0.2mm
1555 +5:Rainfall in last hour: etc 0.2mm
1407 1407  
1408 -6:24-hour maximum rainfall etc  10.0mm
1557 +6:24-hour maximum rainfall: etc  10.0mm
1409 1409  
1410 -8:24-hour minimum rainfall:etc  0.0mm
1559 +8:24-hour minimum rainfall: etc  0.0mm
1411 1411  
1412 -10:Rainfall in 24 hours: 8.0mm  Rainfall in the last 24 hours
1561 +10:Rainfall in 24 hours: 8.0mm  (Rainfall in the last 24 hours)
1413 1413  
1563 +
1414 1414  = 8. Trouble Shooting =
1415 1415  
1416 1416  == 8.1 AT Command input doesn't work ==
... ... @@ -1421,6 +1421,40 @@
1421 1421  )))
1422 1422  
1423 1423  
1574 +== 8.2  Possible reasons why the device is unresponsive: ==
1575 +
1576 +
1577 +~1. Check whether the battery voltage is lower than 2.8V
1578 +2. Check whether the jumper of the device is correctly connected
1579 +
1580 +[[image:image-20240330173709-1.png]]
1581 +
1582 +
1583 +3. Check whether the switch here of the device is at the ISP(The switch can operate normally only when it is in RUN)
1584 +
1585 +[[image:image-20240330173724-2.png]]
1586 +
1587 +
1588 +== 8.3  The rain gauge keeps showing an incorrect value of 102.2 ==
1589 +
1590 +When the rain gauge keeps showing wrong values, it means that the device has exceeded its maximum range.
1591 +Customer need to use RS485-USB to reset it
1592 +
1593 +Wiring method:
1594 +RS485-USB A<~-~-~-~-~-~-->rain gauge RS485A
1595 +RS485-USB B<~-~-~-~-~-~-->rain gauge RS485B
1596 +
1597 +
1598 +Use the reset command:
1599 +
1600 +06 06 00 37 00 03 79 B2
1601 +
1602 +[[image:image-20250219164620-1.png]]
1603 +
1604 +
1605 +
1606 +
1607 +
1424 1424  = 9. Order Info =
1425 1425  
1426 1426  == 9.1 Main Process Unit ==
image-20240330173709-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +445.4 KB
Content
image-20240330173724-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +445.4 KB
Content
image-20250122085744-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +86.9 KB
Content
image-20250122085806-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +109.8 KB
Content
image-20250219164620-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +9.1 KB
Content