Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Mengting Qiu on 2025/03/18 17:31
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. David1 +XWiki.Bei - Content
-
... ... @@ -79,6 +79,7 @@ 79 79 * Mounting Kit includes pole and mast assembly. Each weather sensor has it's own mounting assembly, user can check the sensor section in this manual. 80 80 * Cabinet. 81 81 82 + 82 82 == 2.2 How it works? == 83 83 84 84 ... ... @@ -162,6 +162,7 @@ 162 162 * Valid Sensor Value: Use FPORT=2 163 163 * Other control command: Use FPORT other than 2. 164 164 166 + 165 165 === 2.4.1 Uplink FPORT~=5, Device Status === 166 166 167 167 ... ... @@ -521,6 +521,7 @@ 521 521 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 522 522 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 523 523 526 + 524 524 == 3.2 Set Emergency Mode == 525 525 526 526 ... ... @@ -543,6 +543,7 @@ 543 543 * 0xE101 Same as: AT+ALARMMOD=1 544 544 * 0xE100 Same as: AT+ALARMMOD=0 545 545 549 + 546 546 == 3.3 Add or Delete RS485 Sensor == 547 547 548 548 ... ... @@ -638,6 +638,7 @@ 638 638 639 639 * 0xE5FF 640 640 645 + 641 641 == 3.4 RS485 Test Command == 642 642 643 643 ... ... @@ -658,6 +658,7 @@ 658 658 659 659 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 660 660 666 + 661 661 == 3.5 RS485 response timeout == 662 662 663 663 ... ... @@ -680,6 +680,7 @@ 680 680 * Example 1: Downlink Payload: E0000005 ~/~/ Set Transmit Interval (DTR) = 5 seconds 681 681 * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds 682 682 689 + 683 683 == 3.6 Set Sensor Type == 684 684 685 685 ... ... @@ -802,6 +802,7 @@ 802 802 * IP Rating: IP65 803 803 * Support default sensors or 3rd party RS485 sensors 804 804 812 + 805 805 == 5.2 Power Consumption == 806 806 807 807 ... ... @@ -875,6 +875,7 @@ 875 875 * ABS enclosure. 876 876 * Horizontal adjustable. 877 877 886 + 878 878 === 6.1.2 Specification === 879 879 880 880 ... ... @@ -888,6 +888,7 @@ 888 888 * Working Humidity: <100% (no dewing) 889 889 * Power Consumption: 4mA @ 12v. 890 890 900 + 891 891 === 6.1.3 Dimension === 892 892 893 893 ... ... @@ -964,6 +964,7 @@ 964 964 * RS485 wind speed / direction sensor 965 965 * PC enclosure, resist corrosion 966 966 977 + 967 967 === 6.2.2 Specification === 968 968 969 969 ... ... @@ -978,6 +978,7 @@ 978 978 * Power Consumption: 13mA ~~ 12v. 979 979 * Cable Length: 2 meters 980 980 992 + 981 981 === 6.2.3 Dimension === 982 982 983 983 ... ... @@ -1035,6 +1035,7 @@ 1035 1035 * NDIR to measure CO2 with Internal Temperature Compensation 1036 1036 * Laser Beam Scattering to PM2.5 and PM10 1037 1037 1050 + 1038 1038 === 6.3.2 Specification === 1039 1039 1040 1040 ... ... @@ -1053,6 +1053,7 @@ 1053 1053 ** CO2: 0 ~~ 95%RH 1054 1054 * Power Consumption: 50mA@ 12v. 1055 1055 1069 + 1056 1056 === 6.3.3 Dimension === 1057 1057 1058 1058 ... ... @@ -1100,6 +1100,7 @@ 1100 1100 * Surface heating to dry 1101 1101 * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion 1102 1102 1117 + 1103 1103 === 6.4.2 Specification === 1104 1104 1105 1105 ... ... @@ -1112,6 +1112,7 @@ 1112 1112 ** No heating: 12mA @ 12v, 1113 1113 ** heating: 94ma @ 12v. 1114 1114 1130 + 1115 1115 === 6.4.3 Dimension === 1116 1116 1117 1117 ... ... @@ -1164,6 +1164,7 @@ 1164 1164 1165 1165 * RS485 Temperature, Humidity, Illuminance, Pressure sensor 1166 1166 1183 + 1167 1167 === 6.5.2 Specification === 1168 1168 1169 1169 ... ... @@ -1189,6 +1189,7 @@ 1189 1189 * Working Humidity: 10 ~~ 90%RH 1190 1190 * Power Consumption: 4mA @ 12v 1191 1191 1209 + 1192 1192 === 6.5.3 Dimension === 1193 1193 1194 1194 ... ... @@ -1235,6 +1235,7 @@ 1235 1235 * Measure Total Radiation between 0.3 ~~ 3μm(300 ~~ 3000nm) 1236 1236 * Measure Reflected Radiation if sense area towards ground. 1237 1237 1256 + 1238 1238 === 6.6.2 Specification === 1239 1239 1240 1240 ... ... @@ -1251,6 +1251,7 @@ 1251 1251 * Working Humidity: 10 ~~ 90%RH 1252 1252 * Power Consumption: 4mA @ 12v 1253 1253 1273 + 1254 1254 === 6.6.3 Dimension === 1255 1255 1256 1256 ... ... @@ -1317,6 +1317,7 @@ 1317 1317 * Working Humidity: 10 ~~ 90%RH 1318 1318 * Power Consumption: 3mA @ 12v 1319 1319 1340 + 1320 1320 === 6.7.3 Dimension === 1321 1321 1322 1322 ... ... @@ -1385,12 +1385,6 @@ 1385 1385 See this link for the [[modbus command set>>https://www.dropbox.com/s/rw90apbar029a4w/Weather_Sensors_Modbus_Command_List.xlsx?dl=0]]. 1386 1386 1387 1387 1388 -== 7.6 How to change the data read by the rain gauge? == 1389 - 1390 -AT+RAINFALLSWITCH=1(Range: 1~~10) 1-10 corresponds to the sensor register. 1391 - 1392 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/image-20231030102056-3.png?rev=1.1||alt="image-20231030102056-3.png"]] 1393 - 1394 1394 = 8. Trouble Shooting = 1395 1395 1396 1396 == 8.1 AT Command input doesn't work == ... ... @@ -1419,6 +1419,7 @@ 1419 1419 * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1420 1420 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1421 1421 1437 + 1422 1422 == 9.2 Sensors == 1423 1423 1424 1424 ... ... @@ -1433,6 +1433,7 @@ 1433 1433 |(% style="width:462px" %)Total Solar Radiation Sensor|(% style="width:120px" %)WSS-06 1434 1434 |(% style="width:462px" %)PAR (Photosynthetically Available Radiation)|(% style="width:120px" %)WSS-07 1435 1435 1452 + 1436 1436 = 10. Support = 1437 1437 1438 1438 ... ... @@ -1440,6 +1440,7 @@ 1440 1440 1441 1441 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]. 1442 1442 1460 + 1443 1443 = 11. Appendix I: Field Installation Photo = 1444 1444 1445 1445