From version < 105.9 >
edited by Xiaoling
on 2023/06/16 08:56
To version < 105.14 >
edited by Xiaoling
on 2023/06/16 09:05
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -667,10 +667,9 @@
667 667  
668 668  (% style="color:#037691" %)**AT Command:**
669 669  
670 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:474px" %)
671 -|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 228px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 86px;background-color:#D9E2F3;color:#0070C0" %)**Response**
670 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:494px" %)
671 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 248px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 86px;background-color:#D9E2F3;color:#0070C0" %)**Response**
672 672  |(% style="width:159px" %)AT+RSWRITE=xxxxxx|(% style="width:227px" %)(((
673 -(((
674 674  Send command to 485 sensor. Range : no more than 10 bytes
675 675  )))|(% style="width:85px" %)OK
676 676  
... ... @@ -709,6 +709,10 @@
709 709  * Example 1: Downlink Payload: E0000005  ~/~/  Set Transmit Interval (DTR) = 5 seconds
710 710  * Example 2: Downlink Payload: E000000A  ~/~/  Set Transmit Interval (DTR) = 10 seconds
711 711  
711 +
712 +
713 +
714 +
712 712  == 3.6 Set Sensor Type ==
713 713  
714 714  
... ... @@ -775,17 +775,11 @@
775 775  (% style="color:#037691" %)**AT Command:**
776 776  
777 777  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:433px" %)
778 -|=(% style="width: 161px; background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 184px; background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 86px;background-color:#D9E2F3;color:#0070C0" %)**Response**
781 +|=(% style="width: 172px; background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 175px; background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 86px;background-color:#D9E2F3;color:#0070C0" %)**Response**
779 779  |(% style="width:161px" %)(((
780 -AT+RAINFALLSWITCH=1
781 -
782 -(Range: 1~~10)
783 +AT+RAINFALLSWITCH=1(Range: 1~~10)
783 783  )))|(% style="width:184px" %)(((
784 -(((
785 -(((
786 786  Set the registers read by the rain gauge
787 -)))
788 -)))
789 789  )))|(% style="width:85px" %)OK
790 790  
791 791  (% style="color:#037691" %)**Downlink Command:**
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0