24 -Dragino LoRaWAN weather station series products are designed for measuring atmospheric conditions to provide information for weather forecasts and to study the (% style="color:#4472c4" %)**weather and climate**(%%). They consist of a (% style="color:#4472c4" %)**main process device (WSC1-L) and various sensors**.
24 +Dragino LoRaWAN weather station series products are designed for measuring atmospheric conditions to provide information for weather forecasts and to study the (% style="color:blue" %)**weather and climate**(%%). They consist of a (% style="color:blue" %)**main process device (WSC1-L) and various sensors**.
25 25  )))
26 26  
27 27  (((
28 -The sensors include various type such as: (% style="color:#4472c4" %)**Rain Gauge**, **Temperature/Humidity/Pressure sensor**, **Wind Speed/direction sensor**, **Illumination sensor**, **CO2 sensor**, **Rain/Snow sensor**,** PM2.5/10 sensor**, **PAR(Photosynthetically Available Radiation) sensor, Total Solar Radiation sensor**(%%) and so on.
28 +The sensors include various type such as: (% style="color:blue" %)**Rain Gauge**, **Temperature/Humidity/Pressure sensor**, **Wind Speed/direction sensor**, **Illumination sensor**, **CO2 sensor**, **Rain/Snow sensor**,** PM2.5/10 sensor**, **PAR(Photosynthetically Available Radiation) sensor, Total Solar Radiation sensor**(%%) and so on.
29 29  )))
30 30  
31 31  (((
32 -Main process device WSC1-L is an outdoor LoRaWAN RS485 end node. It is powered by external (% style="color:#4472c4" %)**12v solar power**(%%) and have a (% style="color:#4472c4" %)**built-in li-on backup battery**(%%). WSC1-L reads value from various sensors and upload these sensor data to IoT server via LoRaWAN wireless protocol.
32 +Main process device WSC1-L is an outdoor LoRaWAN RS485 end node. It is powered by external (% style="color:blue" %)**12v solar power**(%%) and have a (% style="color:blue" %)**built-in li-on backup battery**(%%). WSC1-L reads value from various sensors and upload these sensor data to IoT server via LoRaWAN wireless protocol.
33 33  )))
34 34  
35 35  (((
36 -WSC1-L is full compatible with(% style="color:#4472c4" %)** LoRaWAN Class C protocol**(%%), it can work with standard LoRaWAN gateway.
36 +WSC1-L is full compatible with(% style="color:blue" %)** LoRaWAN Class C protocol**(%%), it can work with standard LoRaWAN gateway.
37 37  )))
38 38  
39 39  
... ... @@ -79,6 +79,8 @@
79 79  * Mounting Kit includes pole and mast assembly. Each weather sensor has it's own mounting assembly, user can check the sensor section in this manual.
80 80  * Cabinet.
81 81  
82 +
83 +
82 82  == 2.2 How it works? ==
83 83  
84 84  
... ... @@ -153,6 +153,7 @@
153 153  
154 154  [[image:1656042745346-283.png]]
155 155  
158 +
156 156  == 2.4 Uplink Payload ==
157 157  
158 158  
... ... @@ -161,6 +161,8 @@
161 161  * Valid Sensor Value: Use FPORT=2
162 162  * Other control command: Use FPORT other than 2.
163 163  
167 +
168 +
164 164  === 2.4.1 Uplink FPORT~=5, Device Status ===
165 165  
166 166  
... ... @@ -296,16 +296,11 @@
296 296  
297 297  (% style="color:#4472c4" %)**Sensor Type Table:**
298 298  
299 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:520px" %)
300 -|(% style="background-color:#d9e2f3; color:#0070c0; width:80px" %)**Sensor Type**|(% style="background-color:#d9e2f3; color:#0070c0; width:75px" %)**Type Code**|(% style="background-color:#d9e2f3; color:#0070c0; width:95px" %)**Range**|(% style="background-color:#d9e2f3; color:#0070c0; width:80px" %)**Length( Bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:190px" %)**Example**
304 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
305 +|(% style="background-color:#d9e2f3; color:#0070c0; width:80px" %)**Sensor Type**|(% style="background-color:#d9e2f3; color:#0070c0; width:65px" %)**Type Code**|(% style="background-color:#d9e2f3; color:#0070c0; width:97px" %)**Range**|(% style="background-color:#d9e2f3; color:#0070c0; width:78px" %)**Length( Bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:190px" %)**Example**
301 301  |(% style="width:103px" %)Wind Speed|(% style="width:91px" %)0x01|(% style="width:158px" %)(((
302 -(((
303 -Speed: 0~60m/s
304 -)))
305 -
306 -(((
307 -Level: 0~17
308 -)))
307 +Speed: 0 ~~ 60m/s
308 +Level: 0 ~~ 17
309 309  )))|(% style="width:122px" %)0x03 |(% style="width:904px" %)(((
310 310  (((
311 311  0x0024/10=3.6m/s (0x02FE: No Sensor, 0x02EE: Value Error)
... ... @@ -316,13 +316,8 @@
316 316  )))
317 317  )))
318 318  |(% style="width:103px" %)Wind Direction|(% style="width:91px" %)0x02|(% style="width:158px" %)(((
319 -(((
320 -Angel: 0~360°
321 -)))
322 -
323 -(((
319 +Angel: 0 ~~ 360°
324 324  Direction: 16 positions
325 -)))
326 326  )))|(% style="width:122px" %)0x03|(% style="width:904px" %)(((
327 327  (((
328 328  0x02C9/10=66.6°(0x0EFE: No Sensor,0x0EFF: Value Error)
... ... @@ -379,9 +379,7 @@
379 379  0x00B3=179μmol/m^^2^^•s (0x09FE: No Sensor,0x09FF: Value Error)
380 380  )))
381 381  |(% style="width:103px" %)(((
382 -Total Solar
383 -
384 -Radiation
377 +Total Solar Radiation
385 385  )))|(% style="width:91px" %)0x0D|(% style="width:158px" %)0~2000W/m^^2^^|(% style="width:122px" %)0x02|(% style="width:904px" %)(((
386 386  0x0073/10=11.5W/m^^2^^(0x4EFE: No Sensor,0x4EFF: Value Error)
387 387  )))
... ... @@ -390,9 +390,6 @@
390 390  Below is an example payload:  [[image:image-20220624140615-3.png]]
391 391  )))
392 392  
393 -(((
394 -
395 -)))
396 396  
397 397  (((
398 398  When sending this payload to LoRaWAN server. WSC1-L will send this in one uplink or several uplinks according to LoRaWAN spec requirement. For example, total length of Payload is 54 bytes.
... ... @@ -490,7 +490,7 @@
490 490  
491 491  There are two kinds of commands to configure WSC1-L, they are:
492 492  
493 -* (% style="color:#4472c4" %)**General Commands**.
483 +* (% style="color:blue" %)**General Commands**.
494 494  
495 495  These commands are to configure:
496 496  
... ... @@ -502,7 +502,7 @@
502 502  (% style="color:red" %)**Note~*~*: Please check early user manual if you don’t have v1.8.0 firmware. **
503 503  
504 504  
505 -* (% style="color:#4472c4" %)**Commands special design for WSC1-L**
495 +* (% style="color:blue" %)**Commands special design for WSC1-L**
506 506  
507 507  These commands only valid for WSC1-L, as below:
508 508  
... ... @@ -537,7 +537,6 @@
537 537  
538 538  
539 539  
540 -
541 541  == 3.2 Set Emergency Mode ==
542 542  
543 543  
... ... @@ -562,7 +562,6 @@
562 562  
563 563  
564 564  
565 -
566 566  == 3.3 Add or Delete RS485 Sensor ==
567 567  
568 568  
... ... @@ -660,23 +660,15 @@
660 660  
661 661  
662 662  
663 -
664 -
665 665  == 3.4 RS485 Test Command ==
666 666  
667 667  
668 668  (% style="color:#037691" %)**AT Command:**
669 669  
670 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:474px" %)
671 -|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 228px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 86px;background-color:#D9E2F3;color:#0070C0" %)**Response**
656 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:494px" %)
657 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 248px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 86px;background-color:#D9E2F3;color:#0070C0" %)**Response**
672 672  |(% style="width:159px" %)AT+RSWRITE=xxxxxx|(% style="width:227px" %)(((
673 -(((
674 -Send command to 485 sensor
675 -)))
676 -
677 -(((
678 -Range : no more than 10 bytes
679 -)))
659 +Send command to 485 sensor. Range : no more than 10 bytes
680 680  )))|(% style="width:85px" %)OK
681 681  
682 682  Eg: Send command **01 03 00 00 00 01 84 0A** to 485 sensor
... ... @@ -690,8 +690,6 @@
690 690  
691 691  
692 692  
693 -
694 -
695 695  == 3.5 RS485 response timeout ==
696 696  
697 697  
... ... @@ -714,6 +714,8 @@
714 714  * Example 1: Downlink Payload: E0000005  ~/~/  Set Transmit Interval (DTR) = 5 seconds
715 715  * Example 2: Downlink Payload: E000000A  ~/~/  Set Transmit Interval (DTR) = 10 seconds
716 716  
695 +
696 +
717 717  == 3.6 Set Sensor Type ==
718 718  
719 719  
... ... @@ -774,23 +774,17 @@
774 774  ~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned.
775 775  
776 776  
777 -== 3.7  Set the registers read by the rain gaugeSince firmware V1.3 ==
757 +== 3.7  Set the registers read by the rain gauge(Since firmware V1.3) ==
778 778  
779 779  
780 780  (% style="color:#037691" %)**AT Command:**
781 781  
782 782  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:433px" %)
783 -|=(% style="width: 161px; background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 184px; background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 86px;background-color:#D9E2F3;color:#0070C0" %)**Response**
763 +|=(% style="width: 172px; background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 175px; background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 86px;background-color:#D9E2F3;color:#0070C0" %)**Response**
784 784  |(% style="width:161px" %)(((
785 -AT+RAINFALLSWITCH=1
786 -
787 -(Range: 1~~10)
765 +AT+RAINFALLSWITCH=1(Range: 1~~10)
788 788  )))|(% style="width:184px" %)(((
789 -(((
790 -(((
791 791  Set the registers read by the rain gauge
792 -)))
793 -)))
794 794  )))|(% style="width:85px" %)OK
795 795  
796 796  (% style="color:#037691" %)**Downlink Command:**
... ... @@ -842,6 +842,8 @@
842 842  * IP Rating: IP65
843 843  * Support default sensors or 3rd party RS485 sensors
844 844  
819 +
820 +
845 845  == 5.2 Power Consumption ==
846 846  
847 847  
... ... @@ -915,6 +915,8 @@
915 915  * ABS enclosure.
916 916  * Horizontal adjustable.
917 917  
894 +
895 +
918 918  === 6.1.2 Specification ===
919 919  
920 920  
... ... @@ -921,13 +921,15 @@
921 921  * Resolution: 0.2mm
922 922  * Accuracy: ±3%
923 923  * Range: 0 ~~ 100mm
924 -* Rainfall strength: 0mm4mm/min (max 8mm/min)
925 -* Input Power: DC 5~~24v
902 +* Rainfall strength: 0mm ~~ 4mm/min (max 8mm/min)
903 +* Input Power: DC 5 ~~ 24v
926 926  * Interface: RS485
927 -* Working Temperature: 0℃70℃ ( incorrect below 0 degree, because water become ICE)
905 +* Working Temperature: 0℃ ~~ 70℃ (incorrect below 0 degree, because water become ICE)
928 928  * Working Humidity: <100% (no dewing)
929 929  * Power Consumption: 4mA @ 12v.
930 930  
909 +
910 +
931 931  === 6.1.3 Dimension ===
932 932  
933 933  
... ... @@ -1004,20 +1004,24 @@
1004 1004  * RS485 wind speed / direction sensor
1005 1005  * PC enclosure, resist corrosion
1006 1006  
987 +
988 +
1007 1007  === 6.2.2 Specification ===
1008 1008  
1009 1009  
1010 1010  * Wind speed range: 0 ~~ 60m/s
1011 1011  * Wind direction range: 0 ~~ 360°
1012 -* Start wind speed: ≤0.3m/s
1013 -* Accuracy: ±0.3+0.03Vm/s , ±1°
1014 -* Input Power: DC 5~~24v
994 +* Start wind speed: ≤0.3 m/s
995 +* Accuracy: ±(0.3+0.03V) m/s , ±1°
996 +* Input Power: DC 5 ~~ 24v
1015 1015  * Interface: RS485
1016 -* Working Temperature: -30℃70℃
998 +* Working Temperature: -30℃ ~~ 70℃
1017 1017  * Working Humidity: <100% (no dewing)
1018 1018  * Power Consumption: 13mA ~~ 12v.
1019 1019  * Cable Length: 2 meters
1020 1020  
1003 +
1004 +
1021 1021  === 6.2.3 Dimension ===
1022 1022  
1023 1023  
... ... @@ -1075,24 +1075,28 @@
1075 1075  * NDIR to measure CO2 with Internal Temperature Compensation
1076 1076  * Laser Beam Scattering to PM2.5 and PM10
1077 1077  
1062 +
1063 +
1078 1078  === 6.3.2 Specification ===
1079 1079  
1080 1080  
1081 -* CO2 Range: 05000ppm, accuracy: ±3%F•S25℃
1067 +* CO2 Range: 0 ~~ 5000ppm, accuracy: ±3%F•S(25℃)
1082 1082  * CO2 resolution: 1ppm
1083 -* PM2.5/PM10 Range: 01000μg/m3 , accuracy ±3%F•S25℃
1069 +* PM2.5/PM10 Range: 0 ~~ 1000μg/m3 , accuracy ±3%F•S(25℃)
1084 1084  * PM2.5/PM10 resolution: 1μg/m3
1085 1085  * Input Power: DC 7 ~~ 24v
1086 1086  * Preheat time: 3min
1087 1087  * Interface: RS485
1088 1088  * Working Temperature:
1089 -** CO2: 0℃50℃;
1075 +** CO2: 0℃ ~~ 50℃;
1090 1090  ** PM2.5/PM10: -30 ~~ 50℃
1091 1091  * Working Humidity:
1092 -** PM2.5/PM10: 1580%RH (no dewing)
1093 -** CO2: 095%RH
1078 +** PM2.5/PM10: 15 ~~ 80%RH (no dewing)
1079 +** CO2: 0 ~~ 95%RH
1094 1094  * Power Consumption: 50mA@ 12v.
1095 1095  
1082 +
1083 +
1096 1096  === 6.3.3 Dimension ===
1097 1097  
1098 1098  
... ... @@ -1140,6 +1140,8 @@
1140 1140  * Surface heating to dry
1141 1141  * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion
1142 1142  
1131 +
1132 +
1143 1143  === 6.4.2 Specification ===
1144 1144  
1145 1145  
... ... @@ -1146,12 +1146,14 @@
1146 1146  * Detect if there is rain or snow
1147 1147  * Input Power: DC 12 ~~ 24v
1148 1148  * Interface: RS485
1149 -* Working Temperature: -30℃70℃
1150 -* Working Humidity: 1090%RH
1139 +* Working Temperature: -30℃ ~~ 70℃
1140 +* Working Humidity: 10 ~~ 90%RH
1151 1151  * Power Consumption:
1152 1152  ** No heating: 12mA @ 12v,
1153 1153  ** heating: 94ma @ 12v.
1154 1154  
1145 +
1146 +
1155 1155  === 6.4.3 Dimension ===
1156 1156  
1157 1157  
... ... @@ -1204,6 +1204,8 @@
1204 1204  
1205 1205  * RS485 Temperature, Humidity, Illuminance, Pressure sensor
1206 1206  
1199 +
1200 +
1207 1207  === 6.5.2 Specification ===
1208 1208  
1209 1209  
... ... @@ -1218,17 +1218,19 @@
1218 1218  ** resolution 0.1 %RH
1219 1219  ** Accuracy: 3% RH
1220 1220  * Pressure Sensor Spec:
1221 -** Range: 101100hPa
1215 +** Range: 10 ~~ 1100hPa
1222 1222  ** Resolution: 0.1hPa
1223 1223  ** Accuracy: ±0.1hPa
1224 1224  * Illuminate sensor:
1225 -** Range: 02/20/200kLux
1219 +** Range: 0~~2/20/200kLux
1226 1226  ** Resolution: 10 Lux
1227 -** Accuracy: ±3FS
1228 -* Working Temperature: -30℃70℃
1229 -* Working Humidity: 1090%RH
1221 +** Accuracy: ±3%FS
1222 +* Working Temperature: -30℃ ~~ 70℃
1223 +* Working Humidity: 10 ~~ 90%RH
1230 1230  * Power Consumption: 4mA @ 12v
1231 1231  
1226 +
1227 +
1232 1232  === 6.5.3 Dimension ===
1233 1233  
1234 1234  
... ... @@ -1272,25 +1272,29 @@
1272 1272  
1273 1273  
1274 1274  * RS485 Total Solar Radiation sensor
1275 -* Measure Total Radiation between 0.33μm3003000nm
1271 +* Measure Total Radiation between 0.3 ~~ 3μm(300 ~~ 3000nm)
1276 1276  * Measure Reflected Radiation if sense area towards ground.
1277 1277  
1274 +
1275 +
1278 1278  === 6.6.2 Specification ===
1279 1279  
1280 1280  
1281 1281  * Input Power: DC 5 ~~ 24v
1282 1282  * Interface: RS485
1283 -* Detect spectrum: 0.33μm300~3000nm
1284 -* Measure strength range: 02000W/m2
1281 +* Detect spectrum: 0.3 ~~ 3μm(300~3000nm)
1282 +* Measure strength range: 0 ~~ 2000W/m2
1285 1285  * Resolution: 0.1W/m2
1286 1286  * Accuracy: ±3%
1287 -* Yearly Stability: ≤±2
1288 -* Cosine response: ≤7 (@ Sun angle 10°)
1289 -* Temperature Effect: ±2%(-10℃40℃
1290 -* Working Temperature: -40℃70℃
1291 -* Working Humidity: 1090%RH
1285 +* Yearly Stability: ≤±2%
1286 +* Cosine response: ≤7% (@ Sun angle 10°)
1287 +* Temperature Effect: ±2% (-10℃ ~~ 40℃)
1288 +* Working Temperature: -40℃ ~~ 70℃
1289 +* Working Humidity: 10 ~~ 90%RH
1292 1292  * Power Consumption: 4mA @ 12v
1293 1293  
1292 +
1293 +
1294 1294  === 6.6.3 Dimension ===
1295 1295  
1296 1296  
... ... @@ -1348,15 +1348,17 @@
1348 1348  
1349 1349  * Input Power: DC 5 ~~ 24v
1350 1350  * Interface: RS485
1351 -* Response Spectrum: 400700nm
1352 -* Measure range: 02500μmol/m2•s
1351 +* Response Spectrum: 400~~700nm
1352 +* Measure range: 0 ~~ 2500μmol/m2•s
1353 1353  * Resolution: 1μmol/m2•s
1354 1354  * Accuracy: ±2%
1355 -* Yearly Stability: ≤±2
1356 -* Working Temperature: -30℃75℃
1357 -* Working Humidity: 1090%RH
1355 +* Yearly Stability: ≤ ±2%
1356 +* Working Temperature: -30℃ ~~ 75℃
1357 +* Working Humidity: 10 ~~ 90%RH
1358 1358  * Power Consumption: 3mA @ 12v
1359 1359  
1360 +
1361 +
1360 1360  === 6.7.3 Dimension ===
1361 1361  
1362 1362  
... ... @@ -1399,12 +1399,9 @@
1399 1399  
1400 1400  
1401 1401  (((
1402 -Firmware Location & Change log:
1403 -
1404 -[[https:~~/~~/www.dropbox.com/sh/fuorz31grv8i3r1/AABmjFDU4FADNP6sq7fsmBwVa?dl=0>>https://www.dropbox.com/sh/fuorz31grv8i3r1/AABmjFDU4FADNP6sq7fsmBwVa?dl=0]]
1404 +Firmware Location & Change log: [[https:~~/~~/www.dropbox.com/sh/j6uco1uirwqbng1/AAAwGoxamL5xNJR5Z6CTqGXha?dl=0>>https://www.dropbox.com/sh/j6uco1uirwqbng1/AAAwGoxamL5xNJR5Z6CTqGXha?dl=0]]
1405 1405  )))
1406 1406  
1407 -
1408 1408  (((
1409 1409  Firmware Upgrade instruction:  [[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome||anchor="H2.HardwareUpgradeMethodSupportList"]]
1410 1410  )))
... ... @@ -1456,6 +1456,8 @@
1456 1456  * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
1457 1457  * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
1458 1458  
1458 +
1459 +
1459 1459  == 9.2 Sensors ==
1460 1460  
1461 1461  
... ... @@ -1470,6 +1470,8 @@
1470 1470  |(% style="width:462px" %)Total Solar Radiation Sensor|(% style="width:120px" %)WSS-06
1471 1471  |(% style="width:462px" %)PAR (Photosynthetically Available Radiation)|(% style="width:120px" %)WSS-07
1472 1472  
1474 +
1475 +
1473 1473  = 10. Support =
1474 1474  
1475 1475  
... ... @@ -1477,6 +1477,8 @@
1477 1477  
1478 1478  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]].
1479 1479  
1483 +
1484 +
1480 1480  = 11. Appendix I: Field Installation Photo =
1481 1481  
1482 1482  
image-20231030101817-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +60.0 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved