Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Mengting Qiu on 2025/03/18 17:31
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -667,16 +667,10 @@ 667 667 668 668 (% style="color:#037691" %)**AT Command:** 669 669 670 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:4 74px" %)671 -|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 2 28px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 86px;background-color:#D9E2F3;color:#0070C0" %)**Response**670 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:494px" %) 671 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 248px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 86px;background-color:#D9E2F3;color:#0070C0" %)**Response** 672 672 |(% style="width:159px" %)AT+RSWRITE=xxxxxx|(% style="width:227px" %)((( 673 -((( 674 -Send command to 485 sensor 675 -))) 676 - 677 -((( 678 -Range : no more than 10 bytes 679 -))) 673 +Send command to 485 sensor. Range : no more than 10 bytes 680 680 )))|(% style="width:85px" %)OK 681 681 682 682 Eg: Send command **01 03 00 00 00 01 84 0A** to 485 sensor ... ... @@ -714,6 +714,10 @@ 714 714 * Example 1: Downlink Payload: E0000005 ~/~/ Set Transmit Interval (DTR) = 5 seconds 715 715 * Example 2: Downlink Payload: E000000A ~/~/ Set Transmit Interval (DTR) = 10 seconds 716 716 711 + 712 + 713 + 714 + 717 717 == 3.6 Set Sensor Type == 718 718 719 719 ... ... @@ -774,23 +774,17 @@ 774 774 ~1. The sensor type will not be saved to flash, and the value will be updated every time the sensor is restarted or rescanned. 775 775 776 776 777 -== 3.7 Set the registers read by the rain gauge (Since firmware V1.3)==775 +== 3.7 Set the registers read by the rain gauge(Since firmware V1.3) == 778 778 779 779 780 780 (% style="color:#037691" %)**AT Command:** 781 781 782 782 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:433px" %) 783 -|=(% style="width: 1 61px; background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 184px; background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 86px;background-color:#D9E2F3;color:#0070C0" %)**Response**781 +|=(% style="width: 172px; background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 175px; background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 86px;background-color:#D9E2F3;color:#0070C0" %)**Response** 784 784 |(% style="width:161px" %)((( 785 -AT+RAINFALLSWITCH=1 786 - 787 -(Range: 1~~10) 783 +AT+RAINFALLSWITCH=1(Range: 1~~10) 788 788 )))|(% style="width:184px" %)((( 789 -((( 790 -((( 791 791 Set the registers read by the rain gauge 792 -))) 793 -))) 794 794 )))|(% style="width:85px" %)OK 795 795 796 796 (% style="color:#037691" %)**Downlink Command:**