Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/04/25 09:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -171,7 +171,7 @@ 171 171 User can also use downlink command**(0x2301)** to ask WSC1-L to resend this uplink 172 172 ))) 173 173 174 -(% border="1" cellspacing=" 8" style="background-color:#f2f2f2; width:500px" %)174 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 175 175 |=(% style="width: 70px;background-color:#D9E2F3" %)**Size(**bytes)|=(% style="width: 60px;background-color:#D9E2F3" %)1|=(% style="width: 80px;background-color:#D9E2F3" %)**2**|=(% style="width: 80px;background-color:#D9E2F3" %)**1**|=(% style="width: 60px;background-color:#D9E2F3" %)**1**|=(% style="width: 50px;background-color:#D9E2F3" %)**2**|=(% style="width: 100px;background-color:#D9E2F3" %)**3** 176 176 |(% style="width:99px" %)**Value**|(% style="width:112px" %)[[Sensor Model>>||anchor="HSensorModel:"]]|(% style="width:135px" %)[[Firmware Version>>||anchor="HFirmwareVersion:"]]|(% style="width:126px" %)[[Frequency Band>>||anchor="HFrequencyBand:"]]|(% style="width:85px" %)[[Sub-band>>||anchor="HSub-Band:"]]|(% style="width:46px" %)[[BAT>>||anchor="HBAT:"]]|(% style="width:166px" %)[[Weather Sensor Types>>||anchor="HWeatherSensorTypes:"]] 177 177 ... ... @@ -193,25 +193,25 @@ 193 193 194 194 ==== (% style="color:#037691" %)**Frequency Band:**(%%) ==== 195 195 196 - *0x01: EU868196 +0x01: EU868 197 197 198 - *0x02: US915198 +0x02: US915 199 199 200 - *0x03: IN865200 +0x03: IN865 201 201 202 - *0x04: AU915202 +0x04: AU915 203 203 204 - *0x05: KZ865204 +0x05: KZ865 205 205 206 - *0x06: RU864206 +0x06: RU864 207 207 208 - *0x07: AS923208 +0x07: AS923 209 209 210 - *0x08: AS923-1210 +0x08: AS923-1 211 211 212 - *0x09: AS923-2212 +0x09: AS923-2 213 213 214 - *0x0a: AS923-3214 +0x0a: AS923-3 215 215 216 216 217 217 ==== (% style="color:#037691" %)**Sub-Band:**(%%) ==== ... ... @@ -535,6 +535,9 @@ 535 535 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 536 536 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 537 537 538 + 539 + 540 + 538 538 == 3.2 Set Emergency Mode == 539 539 540 540 ... ... @@ -542,8 +542,8 @@ 542 542 543 543 (% style="color:#037691" %)**AT Command:** 544 544 545 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:46 5.818px" %)546 -|(% style="background-color:#d9e2f3; color:#0070c0; width:15 5px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:224px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:84px" %)**Response**548 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:466px" %) 549 +|(% style="background-color:#d9e2f3; color:#0070c0; width:156px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:225px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:85px" %)**Response** 547 547 |(% style="width:155px" %)AT+ALARMMOD=1|(% style="width:224px" %)Enter emergency mode. Uplink every 1 minute|(% style="width:84px" %)((( 548 548 OK 549 549 ... ... @@ -557,6 +557,9 @@ 557 557 * 0xE101 Same as: AT+ALARMMOD=1 558 558 * 0xE100 Same as: AT+ALARMMOD=0 559 559 563 + 564 + 565 + 560 560 == 3.3 Add or Delete RS485 Sensor == 561 561 562 562 ... ... @@ -652,21 +652,19 @@ 652 652 653 653 * 0xE5FF 654 654 661 + 662 + 663 + 664 + 655 655 == 3.4 RS485 Test Command == 656 656 657 657 658 658 (% style="color:#037691" %)**AT Command:** 659 659 660 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:4 74px" %)661 -|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 2 28px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 86px;background-color:#D9E2F3;color:#0070C0" %)**Response**670 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:494px" %) 671 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 248px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 86px;background-color:#D9E2F3;color:#0070C0" %)**Response** 662 662 |(% style="width:159px" %)AT+RSWRITE=xxxxxx|(% style="width:227px" %)((( 663 -((( 664 -Send command to 485 sensor 665 -))) 666 - 667 -((( 668 -Range : no more than 10 bytes 669 -))) 673 +Send command to 485 sensor. Range : no more than 10 bytes 670 670 )))|(% style="width:85px" %)OK 671 671 672 672 Eg: Send command **01 03 00 00 00 01 84 0A** to 485 sensor ... ... @@ -678,6 +678,10 @@ 678 678 679 679 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 680 680 685 + 686 + 687 + 688 + 681 681 == 3.5 RS485 response timeout == 682 682 683 683 ... ... @@ -688,17 +688,7 @@ 688 688 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:433px" %) 689 689 |=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 86px;background-color:#D9E2F3;color:#0070C0" %)**Response** 690 690 |(% style="width:157px" %)AT+DTR=1000|(% style="width:188px" %)((( 691 -((( 692 -((( 693 -Set response timeout to: 694 -))) 695 -))) 696 - 697 -((( 698 -((( 699 -Range : 0~~10000 700 -))) 701 -))) 699 +Set response timeout to: Range : 0~~10000 702 702 )))|(% style="width:85px" %)OK 703 703 704 704 (% style="color:#037691" %)**Downlink Command:**