Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Mengting Qiu on 2025/03/18 17:31
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1078,9 +1078,9 @@ 1078 1078 === 6.3.2 Specification === 1079 1079 1080 1080 1081 -* CO2 Range: 0~5000ppm, accuracy: ±3%F•S (25℃)1081 +* CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃) 1082 1082 * CO2 resolution: 1ppm 1083 -* PM2.5/PM10 Range: 0~1000μg/m3 , accuracy ±3%F•S (25℃)1083 +* PM2.5/PM10 Range: 0~1000μg/m3 , accuracy ±3%F•S(25℃) 1084 1084 * PM2.5/PM10 resolution: 1μg/m3 1085 1085 * Input Power: DC 7 ~~ 24v 1086 1086 * Preheat time: 3min ... ... @@ -1093,10 +1093,6 @@ 1093 1093 ** CO2: 0~95%RH 1094 1094 * Power Consumption: 50mA@ 12v. 1095 1095 1096 - 1097 - 1098 - 1099 - 1100 1100 === 6.3.3 Dimension === 1101 1101 1102 1102 ... ... @@ -1222,15 +1222,15 @@ 1222 1222 ** resolution 0.1 %RH 1223 1223 ** Accuracy: 3% RH 1224 1224 * Pressure Sensor Spec: 1225 -** Range: 10 ~~1100hPa1221 +** Range: 10~1100hPa 1226 1226 ** Resolution: 0.1hPa 1227 1227 ** Accuracy: ±0.1hPa 1228 1228 * Illuminate sensor: 1229 -** Range: 0 ~~2/20/200kLux1225 +** Range: 0~2/20/200kLux 1230 1230 ** Resolution: 10 Lux 1231 -** Accuracy: ±3 %FS1232 -* Working Temperature: -30℃ ~~70℃1233 -* Working Humidity: 10 ~~90%RH1227 +** Accuracy: ±3%FS 1228 +* Working Temperature: -30℃~70℃ 1229 +* Working Humidity: 10~90%RH 1234 1234 * Power Consumption: 4mA @ 12v 1235 1235 1236 1236 === 6.5.3 Dimension === ... ... @@ -1276,33 +1276,25 @@ 1276 1276 1277 1277 1278 1278 * RS485 Total Solar Radiation sensor 1279 -* Measure Total Radiation between 0.3~3μm (300~3000nm)1275 +* Measure Total Radiation between 0.3~3μm(300~3000nm) 1280 1280 * Measure Reflected Radiation if sense area towards ground. 1281 1281 1282 - 1283 - 1284 - 1285 - 1286 1286 === 6.6.2 Specification === 1287 1287 1288 1288 1289 1289 * Input Power: DC 5 ~~ 24v 1290 1290 * Interface: RS485 1291 -* Detect spectrum: 0.3~3μm (300~3000nm)1283 +* Detect spectrum: 0.3~3μm(300~3000nm) 1292 1292 * Measure strength range: 0~2000W/m2 1293 1293 * Resolution: 0.1W/m2 1294 1294 * Accuracy: ±3% 1295 -* Yearly Stability: ≤±2 %1296 -* Cosine response: ≤7 %(@ Sun angle 10°)1297 -* Temperature Effect: ±2 %(-10℃~~40℃)1298 -* Working Temperature: -40℃ ~~70℃1299 -* Working Humidity: 10 ~~90%RH1287 +* Yearly Stability: ≤±2% 1288 +* Cosine response: ≤7% (@ Sun angle 10°) 1289 +* Temperature Effect: ±2%(-10℃~40℃) 1290 +* Working Temperature: -40℃~70℃ 1291 +* Working Humidity: 10~90%RH 1300 1300 * Power Consumption: 4mA @ 12v 1301 1301 1302 - 1303 - 1304 - 1305 - 1306 1306 === 6.6.3 Dimension === 1307 1307 1308 1308 ... ... @@ -1369,9 +1369,6 @@ 1369 1369 * Working Humidity: 10~90%RH 1370 1370 * Power Consumption: 3mA @ 12v 1371 1371 1372 - 1373 - 1374 - 1375 1375 === 6.7.3 Dimension === 1376 1376 1377 1377