1007 1007  * Wind direction range: 0 ~~ 360°
1008 1008  * Start wind speed: ≤0.3 m/s
1009 1009  * Accuracy: ±(0.3+0.03V) m/s , ±1°
1010 -* Input Power: DC 5~~24v
1010 +* Input Power: DC 5 ~~ 24v
1011 1011  * Interface: RS485
1012 -* Working Temperature: -30℃70℃
1012 +* Working Temperature: -30℃ ~~ 70℃
1013 1013  * Working Humidity: <100% (no dewing)
1014 1014  * Power Consumption: 13mA ~~ 12v.
1015 1015  * Cable Length: 2 meters
... ... @@ -1075,22 +1075,25 @@
1075 1075  * NDIR to measure CO2 with Internal Temperature Compensation
1076 1076  * Laser Beam Scattering to PM2.5 and PM10
1077 1077  
1078 +
1079 +
1080 +
1078 1078  === 6.3.2 Specification ===
1079 1079  
1080 1080  
1081 -* CO2 Range: 05000ppm, accuracy: ±3%F•S(25℃)
1084 +* CO2 Range: 0 ~~ 5000ppm, accuracy: ±3%F•S(25℃)
1082 1082  * CO2 resolution: 1ppm
1083 -* PM2.5/PM10 Range: 01000μg/m3 , accuracy ±3%F•S(25℃)
1086 +* PM2.5/PM10 Range: 0 ~~ 1000μg/m3 , accuracy ±3%F•S(25℃)
1084 1084  * PM2.5/PM10 resolution: 1μg/m3
1085 1085  * Input Power: DC 7 ~~ 24v
1086 1086  * Preheat time: 3min
1087 1087  * Interface: RS485
1088 1088  * Working Temperature:
1089 -** CO2: 0℃50℃;
1092 +** CO2: 0℃ ~~ 50℃;
1090 1090  ** PM2.5/PM10: -30 ~~ 50℃
1091 1091  * Working Humidity:
1092 -** PM2.5/PM10: 1580%RH (no dewing)
1093 -** CO2: 095%RH
1095 +** PM2.5/PM10: 15 ~~ 80%RH (no dewing)
1096 +** CO2: 0 ~~ 95%RH
1094 1094  * Power Consumption: 50mA@ 12v.
1095 1095  
1096 1096  
... ... @@ -1144,6 +1144,9 @@
1144 1144  * Surface heating to dry
1145 1145  * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion
1146 1146  
1150 +
1151 +
1152 +
1147 1147  === 6.4.2 Specification ===
1148 1148  
1149 1149  
... ... @@ -1150,12 +1150,15 @@
1150 1150  * Detect if there is rain or snow
1151 1151  * Input Power: DC 12 ~~ 24v
1152 1152  * Interface: RS485
1153 -* Working Temperature: -30℃70℃
1154 -* Working Humidity: 1090%RH
1159 +* Working Temperature: -30℃ ~~ 70℃
1160 +* Working Humidity: 10 ~~ 90%RH
1155 1155  * Power Consumption:
1156 1156  ** No heating: 12mA @ 12v,
1157 1157  ** heating: 94ma @ 12v.
1158 1158  
1165 +
1166 +
1167 +
1159 1159  === 6.4.3 Dimension ===
1160 1160  
1161 1161  
... ... @@ -1208,6 +1208,9 @@
1208 1208  
1209 1209  * RS485 Temperature, Humidity, Illuminance, Pressure sensor
1210 1210  
1220 +
1221 +
1222 +
1211 1211  === 6.5.2 Specification ===
1212 1212  
1213 1213  
... ... @@ -1222,17 +1222,20 @@
1222 1222  ** resolution 0.1 %RH
1223 1223  ** Accuracy: 3% RH
1224 1224  * Pressure Sensor Spec:
1225 -** Range: 101100hPa
1237 +** Range: 10 ~~ 1100hPa
1226 1226  ** Resolution: 0.1hPa
1227 1227  ** Accuracy: ±0.1hPa
1228 1228  * Illuminate sensor:
1229 -** Range: 02/20/200kLux
1241 +** Range: 0~~2/20/200kLux
1230 1230  ** Resolution: 10 Lux
1231 -** Accuracy: ±3FS
1232 -* Working Temperature: -30℃70℃
1233 -* Working Humidity: 1090%RH
1243 +** Accuracy: ±3%FS
1244 +* Working Temperature: -30℃ ~~ 70℃
1245 +* Working Humidity: 10 ~~ 90%RH
1234 1234  * Power Consumption: 4mA @ 12v
1235 1235  
1248 +
1249 +
1250 +
1236 1236  === 6.5.3 Dimension ===
1237 1237  
1238 1238  
... ... @@ -1288,15 +1288,15 @@
1288 1288  
1289 1289  * Input Power: DC 5 ~~ 24v
1290 1290  * Interface: RS485
1291 -* Detect spectrum: 0.33μm(300~3000nm)
1292 -* Measure strength range: 02000W/m2
1306 +* Detect spectrum: 0.3 ~~ 3μm(300~3000nm)
1307 +* Measure strength range: 0 ~~ 2000W/m2
1293 1293  * Resolution: 0.1W/m2
1294 1294  * Accuracy: ±3%
1295 -* Yearly Stability: ≤±2
1296 -* Cosine response: ≤7 (@ Sun angle 10°)
1297 -* Temperature Effect: ±2(-10℃40℃)
1298 -* Working Temperature: -40℃70℃
1299 -* Working Humidity: 1090%RH
1310 +* Yearly Stability: ≤±2%
1311 +* Cosine response: ≤7% (@ Sun angle 10°)
1312 +* Temperature Effect: ±2%(-10℃ ~~ 40℃)
1313 +* Working Temperature: -40℃ ~~ 70℃
1314 +* Working Humidity: 10 ~~ 90%RH
1300 1300  * Power Consumption: 4mA @ 12v
1301 1301  
1302 1302  
... ... @@ -1360,13 +1360,13 @@
1360 1360  
1361 1361  * Input Power: DC 5 ~~ 24v
1362 1362  * Interface: RS485
1363 -* Response Spectrum: 400700nm
1364 -* Measure range: 02500μmol/m2•s
1378 +* Response Spectrum: 400~~700nm
1379 +* Measure range: 0 ~~ 2500μmol/m2•s
1365 1365  * Resolution: 1μmol/m2•s
1366 1366  * Accuracy: ±2%
1367 -* Yearly Stability: ≤±2
1368 -* Working Temperature: -30℃75℃
1369 -* Working Humidity: 1090%RH
1382 +* Yearly Stability: ≤ ±2%
1383 +* Working Temperature: -30℃ ~~ 75℃
1384 +* Working Humidity: 10 ~~ 90%RH
1370 1370  * Power Consumption: 3mA @ 12v