Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Mengting Qiu on 2025/03/18 17:31
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1078,9 +1078,9 @@ 1078 1078 === 6.3.2 Specification === 1079 1079 1080 1080 1081 -* CO2 Range: 0~5000ppm, accuracy: ±3%F•S (25℃)1081 +* CO2 Range: 0~5000ppm, accuracy: ±3%F•S(25℃) 1082 1082 * CO2 resolution: 1ppm 1083 -* PM2.5/PM10 Range: 0~1000μg/m3 , accuracy ±3%F•S (25℃)1083 +* PM2.5/PM10 Range: 0~1000μg/m3 , accuracy ±3%F•S(25℃) 1084 1084 * PM2.5/PM10 resolution: 1μg/m3 1085 1085 * Input Power: DC 7 ~~ 24v 1086 1086 * Preheat time: 3min ... ... @@ -1093,6 +1093,10 @@ 1093 1093 ** CO2: 0~95%RH 1094 1094 * Power Consumption: 50mA@ 12v. 1095 1095 1096 + 1097 + 1098 + 1099 + 1096 1096 === 6.3.3 Dimension === 1097 1097 1098 1098 ... ... @@ -1218,15 +1218,15 @@ 1218 1218 ** resolution 0.1 %RH 1219 1219 ** Accuracy: 3% RH 1220 1220 * Pressure Sensor Spec: 1221 -** Range: 10 ~1100hPa1225 +** Range: 10~~1100hPa 1222 1222 ** Resolution: 0.1hPa 1223 1223 ** Accuracy: ±0.1hPa 1224 1224 * Illuminate sensor: 1225 -** Range: 0 ~2/20/200kLux1229 +** Range: 0~~2/20/200kLux 1226 1226 ** Resolution: 10 Lux 1227 -** Accuracy: ±3 %FS1228 -* Working Temperature: -30℃ ~70℃1229 -* Working Humidity: 10 ~90%RH1231 +** Accuracy: ±3%FS 1232 +* Working Temperature: -30℃~~70℃ 1233 +* Working Humidity: 10~~90%RH 1230 1230 * Power Consumption: 4mA @ 12v 1231 1231 1232 1232 === 6.5.3 Dimension === ... ... @@ -1272,25 +1272,33 @@ 1272 1272 1273 1273 1274 1274 * RS485 Total Solar Radiation sensor 1275 -* Measure Total Radiation between 0.3~3μm (300~3000nm)1279 +* Measure Total Radiation between 0.3~3μm(300~3000nm) 1276 1276 * Measure Reflected Radiation if sense area towards ground. 1277 1277 1282 + 1283 + 1284 + 1285 + 1278 1278 === 6.6.2 Specification === 1279 1279 1280 1280 1281 1281 * Input Power: DC 5 ~~ 24v 1282 1282 * Interface: RS485 1283 -* Detect spectrum: 0.3~3μm (300~3000nm)1291 +* Detect spectrum: 0.3~3μm(300~3000nm) 1284 1284 * Measure strength range: 0~2000W/m2 1285 1285 * Resolution: 0.1W/m2 1286 1286 * Accuracy: ±3% 1287 -* Yearly Stability: ≤±2 %1288 -* Cosine response: ≤7 %(@ Sun angle 10°)1289 -* Temperature Effect: ±2 %(-10℃~40℃)1290 -* Working Temperature: -40℃ ~70℃1291 -* Working Humidity: 10 ~90%RH1295 +* Yearly Stability: ≤±2% 1296 +* Cosine response: ≤7% (@ Sun angle 10°) 1297 +* Temperature Effect: ±2%(-10℃~~40℃) 1298 +* Working Temperature: -40℃~~70℃ 1299 +* Working Humidity: 10~~90%RH 1292 1292 * Power Consumption: 4mA @ 12v 1293 1293 1302 + 1303 + 1304 + 1305 + 1294 1294 === 6.6.3 Dimension === 1295 1295 1296 1296 ... ... @@ -1357,6 +1357,9 @@ 1357 1357 * Working Humidity: 10~90%RH 1358 1358 * Power Consumption: 3mA @ 12v 1359 1359 1372 + 1373 + 1374 + 1360 1360 === 6.7.3 Dimension === 1361 1361 1362 1362