Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Mengting Qiu on 2025/03/18 17:31
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -21,19 +21,19 @@ 21 21 22 22 23 23 ((( 24 -Dragino LoRaWAN weather station series products are designed for measuring atmospheric conditions to provide information for weather forecasts and to study the (% style="color: #4472c4" %)**weather and climate**(%%). They consist of a (% style="color:#4472c4" %)**main process device (WSC1-L) and various sensors**.24 +Dragino LoRaWAN weather station series products are designed for measuring atmospheric conditions to provide information for weather forecasts and to study the (% style="color:blue" %)**weather and climate**(%%). They consist of a (% style="color:blue" %)**main process device (WSC1-L) and various sensors**. 25 25 ))) 26 26 27 27 ((( 28 -The sensors include various type such as: (% style="color: #4472c4" %)**Rain Gauge**, **Temperature/Humidity/Pressure sensor**, **Wind Speed/direction sensor**, **Illumination sensor**, **CO2 sensor**, **Rain/Snow sensor**,** PM2.5/10 sensor**, **PAR(Photosynthetically Available Radiation) sensor, Total Solar Radiation sensor**(%%) and so on.28 +The sensors include various type such as: (% style="color:blue" %)**Rain Gauge**, **Temperature/Humidity/Pressure sensor**, **Wind Speed/direction sensor**, **Illumination sensor**, **CO2 sensor**, **Rain/Snow sensor**,** PM2.5/10 sensor**, **PAR(Photosynthetically Available Radiation) sensor, Total Solar Radiation sensor**(%%) and so on. 29 29 ))) 30 30 31 31 ((( 32 -Main process device WSC1-L is an outdoor LoRaWAN RS485 end node. It is powered by external (% style="color: #4472c4" %)**12v solar power**(%%) and have a (% style="color:#4472c4" %)**built-in li-on backup battery**(%%). WSC1-L reads value from various sensors and upload these sensor data to IoT server via LoRaWAN wireless protocol.32 +Main process device WSC1-L is an outdoor LoRaWAN RS485 end node. It is powered by external (% style="color:blue" %)**12v solar power**(%%) and have a (% style="color:blue" %)**built-in li-on backup battery**(%%). WSC1-L reads value from various sensors and upload these sensor data to IoT server via LoRaWAN wireless protocol. 33 33 ))) 34 34 35 35 ((( 36 -WSC1-L is full compatible with(% style="color: #4472c4" %)** LoRaWAN Class C protocol**(%%), it can work with standard LoRaWAN gateway.36 +WSC1-L is full compatible with(% style="color:blue" %)** LoRaWAN Class C protocol**(%%), it can work with standard LoRaWAN gateway. 37 37 ))) 38 38 39 39 ... ... @@ -996,20 +996,28 @@ 996 996 * RS485 wind speed / direction sensor 997 997 * PC enclosure, resist corrosion 998 998 999 + 1000 + 1001 + 1002 + 999 999 === 6.2.2 Specification === 1000 1000 1001 1001 1002 1002 * Wind speed range: 0 ~~ 60m/s 1003 1003 * Wind direction range: 0 ~~ 360° 1004 -* Start wind speed: ≤0.3m/s 1005 -* Accuracy: ± (0.3+0.03V)m/s , ±1°1006 -* Input Power: DC 5~~24v 1008 +* Start wind speed: ≤0.3 m/s 1009 +* Accuracy: ±(0.3+0.03V) m/s , ±1° 1010 +* Input Power: DC 5 ~~ 24v 1007 1007 * Interface: RS485 1008 -* Working Temperature: -30℃ ~70℃1012 +* Working Temperature: -30℃ ~~ 70℃ 1009 1009 * Working Humidity: <100% (no dewing) 1010 1010 * Power Consumption: 13mA ~~ 12v. 1011 1011 * Cable Length: 2 meters 1012 1012 1017 + 1018 + 1019 + 1020 + 1013 1013 === 6.2.3 Dimension === 1014 1014 1015 1015 ... ... @@ -1067,24 +1067,31 @@ 1067 1067 * NDIR to measure CO2 with Internal Temperature Compensation 1068 1068 * Laser Beam Scattering to PM2.5 and PM10 1069 1069 1078 + 1079 + 1080 + 1070 1070 === 6.3.2 Specification === 1071 1071 1072 1072 1073 -* CO2 Range: 0 ~5000ppm, accuracy: ±3%F•S(25℃)1084 +* CO2 Range: 0 ~~ 5000ppm, accuracy: ±3%F•S(25℃) 1074 1074 * CO2 resolution: 1ppm 1075 -* PM2.5/PM10 Range: 0 ~1000μg/m3 , accuracy ±3%F•S(25℃)1086 +* PM2.5/PM10 Range: 0 ~~ 1000μg/m3 , accuracy ±3%F•S(25℃) 1076 1076 * PM2.5/PM10 resolution: 1μg/m3 1077 1077 * Input Power: DC 7 ~~ 24v 1078 1078 * Preheat time: 3min 1079 1079 * Interface: RS485 1080 1080 * Working Temperature: 1081 -** CO2: 0℃ ~50℃;1092 +** CO2: 0℃ ~~ 50℃; 1082 1082 ** PM2.5/PM10: -30 ~~ 50℃ 1083 1083 * Working Humidity: 1084 -** PM2.5/PM10: 15 ~80%RH (no dewing)1085 -** CO2: 0 ~95%RH1095 +** PM2.5/PM10: 15 ~~ 80%RH (no dewing) 1096 +** CO2: 0 ~~ 95%RH 1086 1086 * Power Consumption: 50mA@ 12v. 1087 1087 1099 + 1100 + 1101 + 1102 + 1088 1088 === 6.3.3 Dimension === 1089 1089 1090 1090 ... ... @@ -1132,6 +1132,9 @@ 1132 1132 * Surface heating to dry 1133 1133 * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion 1134 1134 1150 + 1151 + 1152 + 1135 1135 === 6.4.2 Specification === 1136 1136 1137 1137 ... ... @@ -1138,12 +1138,15 @@ 1138 1138 * Detect if there is rain or snow 1139 1139 * Input Power: DC 12 ~~ 24v 1140 1140 * Interface: RS485 1141 -* Working Temperature: -30℃ ~70℃1142 -* Working Humidity: 10 ~90%RH1159 +* Working Temperature: -30℃ ~~ 70℃ 1160 +* Working Humidity: 10 ~~ 90%RH 1143 1143 * Power Consumption: 1144 1144 ** No heating: 12mA @ 12v, 1145 1145 ** heating: 94ma @ 12v. 1146 1146 1165 + 1166 + 1167 + 1147 1147 === 6.4.3 Dimension === 1148 1148 1149 1149 ... ... @@ -1196,6 +1196,9 @@ 1196 1196 1197 1197 * RS485 Temperature, Humidity, Illuminance, Pressure sensor 1198 1198 1220 + 1221 + 1222 + 1199 1199 === 6.5.2 Specification === 1200 1200 1201 1201 ... ... @@ -1210,17 +1210,20 @@ 1210 1210 ** resolution 0.1 %RH 1211 1211 ** Accuracy: 3% RH 1212 1212 * Pressure Sensor Spec: 1213 -** Range: 10 ~1100hPa1237 +** Range: 10 ~~ 1100hPa 1214 1214 ** Resolution: 0.1hPa 1215 1215 ** Accuracy: ±0.1hPa 1216 1216 * Illuminate sensor: 1217 -** Range: 0 ~2/20/200kLux1241 +** Range: 0~~2/20/200kLux 1218 1218 ** Resolution: 10 Lux 1219 -** Accuracy: ±3 %FS1220 -* Working Temperature: -30℃ ~70℃1221 -* Working Humidity: 10 ~90%RH1243 +** Accuracy: ±3%FS 1244 +* Working Temperature: -30℃ ~~ 70℃ 1245 +* Working Humidity: 10 ~~ 90%RH 1222 1222 * Power Consumption: 4mA @ 12v 1223 1223 1248 + 1249 + 1250 + 1224 1224 === 6.5.3 Dimension === 1225 1225 1226 1226 ... ... @@ -1264,25 +1264,33 @@ 1264 1264 1265 1265 1266 1266 * RS485 Total Solar Radiation sensor 1267 -* Measure Total Radiation between 0.3~3μm (300~3000nm)1294 +* Measure Total Radiation between 0.3~3μm(300~3000nm) 1268 1268 * Measure Reflected Radiation if sense area towards ground. 1269 1269 1297 + 1298 + 1299 + 1300 + 1270 1270 === 6.6.2 Specification === 1271 1271 1272 1272 1273 1273 * Input Power: DC 5 ~~ 24v 1274 1274 * Interface: RS485 1275 -* Detect spectrum: 0.3 ~3μm(300~3000nm)1276 -* Measure strength range: 0 ~2000W/m21306 +* Detect spectrum: 0.3 ~~ 3μm(300~3000nm) 1307 +* Measure strength range: 0 ~~ 2000W/m2 1277 1277 * Resolution: 0.1W/m2 1278 1278 * Accuracy: ±3% 1279 -* Yearly Stability: ≤±2 %1280 -* Cosine response: ≤7 %(@ Sun angle 10°)1281 -* Temperature Effect: ±2 %(-10℃~40℃)1282 -* Working Temperature: -40℃ ~70℃1283 -* Working Humidity: 10 ~90%RH1310 +* Yearly Stability: ≤±2% 1311 +* Cosine response: ≤7% (@ Sun angle 10°) 1312 +* Temperature Effect: ±2%(-10℃ ~~ 40℃) 1313 +* Working Temperature: -40℃ ~~ 70℃ 1314 +* Working Humidity: 10 ~~ 90%RH 1284 1284 * Power Consumption: 4mA @ 12v 1285 1285 1317 + 1318 + 1319 + 1320 + 1286 1286 === 6.6.3 Dimension === 1287 1287 1288 1288 ... ... @@ -1340,15 +1340,18 @@ 1340 1340 1341 1341 * Input Power: DC 5 ~~ 24v 1342 1342 * Interface: RS485 1343 -* Response Spectrum: 400 ~700nm1344 -* Measure range: 0 ~2500μmol/m2•s1378 +* Response Spectrum: 400~~700nm 1379 +* Measure range: 0 ~~ 2500μmol/m2•s 1345 1345 * Resolution: 1μmol/m2•s 1346 1346 * Accuracy: ±2% 1347 -* Yearly Stability: ≤±2 %1348 -* Working Temperature: -30℃ ~75℃1349 -* Working Humidity: 10 ~90%RH1382 +* Yearly Stability: ≤ ±2% 1383 +* Working Temperature: -30℃ ~~ 75℃ 1384 +* Working Humidity: 10 ~~ 90%RH 1350 1350 * Power Consumption: 3mA @ 12v 1351 1351 1387 + 1388 + 1389 + 1352 1352 === 6.7.3 Dimension === 1353 1353 1354 1354