Changes for page WSC1-L-Dragino LoRaWAN Weather Station User Manual
Last modified by Xiaoling on 2025/04/25 09:08
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -535,9 +535,6 @@ 535 535 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 536 536 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 537 537 538 - 539 - 540 - 541 541 == 3.2 Set Emergency Mode == 542 542 543 543 ... ... @@ -545,8 +545,8 @@ 545 545 546 546 (% style="color:#037691" %)**AT Command:** 547 547 548 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:46 6px" %)549 -|(% style="background-color:#d9e2f3; color:#0070c0; width:15 6px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:225px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:85px" %)**Response**545 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:465.818px" %) 546 +|(% style="background-color:#d9e2f3; color:#0070c0; width:155px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:224px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:84px" %)**Response** 550 550 |(% style="width:155px" %)AT+ALARMMOD=1|(% style="width:224px" %)Enter emergency mode. Uplink every 1 minute|(% style="width:84px" %)((( 551 551 OK 552 552 ... ... @@ -560,9 +560,6 @@ 560 560 * 0xE101 Same as: AT+ALARMMOD=1 561 561 * 0xE100 Same as: AT+ALARMMOD=0 562 562 563 - 564 - 565 - 566 566 == 3.3 Add or Delete RS485 Sensor == 567 567 568 568 ... ... @@ -658,19 +658,21 @@ 658 658 659 659 * 0xE5FF 660 660 661 - 662 - 663 - 664 - 665 665 == 3.4 RS485 Test Command == 666 666 667 667 668 668 (% style="color:#037691" %)**AT Command:** 669 669 670 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:4 94px" %)671 -|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 2 48px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 86px;background-color:#D9E2F3;color:#0070C0" %)**Response**660 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:474px" %) 661 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 228px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 86px;background-color:#D9E2F3;color:#0070C0" %)**Response** 672 672 |(% style="width:159px" %)AT+RSWRITE=xxxxxx|(% style="width:227px" %)((( 673 -Send command to 485 sensor. Range : no more than 10 bytes 663 +((( 664 +Send command to 485 sensor 665 +))) 666 + 667 +((( 668 +Range : no more than 10 bytes 669 +))) 674 674 )))|(% style="width:85px" %)OK 675 675 676 676 Eg: Send command **01 03 00 00 00 01 84 0A** to 485 sensor ... ... @@ -682,10 +682,6 @@ 682 682 683 683 * 0xE20103000001840A Same as: AT+RSWRITE=0103000001840A 684 684 685 - 686 - 687 - 688 - 689 689 == 3.5 RS485 response timeout == 690 690 691 691 ... ... @@ -696,7 +696,17 @@ 696 696 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:433px" %) 697 697 |=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 86px;background-color:#D9E2F3;color:#0070C0" %)**Response** 698 698 |(% style="width:157px" %)AT+DTR=1000|(% style="width:188px" %)((( 699 -Set response timeout to: Range : 0~~10000 691 +((( 692 +((( 693 +Set response timeout to: 694 +))) 695 +))) 696 + 697 +((( 698 +((( 699 +Range : 0~~10000 700 +))) 701 +))) 700 700 )))|(% style="width:85px" %)OK 701 701 702 702 (% style="color:#037691" %)**Downlink Command:**